**MPMC AIO-20 Hybrid Power Station Owner’s Manual
**
Design Standards
AIO® is a new range of secure integratedhybridpower station. With diesel generator, solar power, battery storage,wind turbineandhybridsolar Inverter in one secure unit. AIO® is mainly developed for residentsPower, Reduce the dependence on Main Power anddecrease the consumption cost.
Benefits
- Integrated installation, convenient storageandtransportation;
- High return on investment and quick return;
- Simple operation and easy maintenance;
- Power and Capacity can be expanded, meet different user needs;
Accept customer customization, suitablefor various scenarios;
Warranty
Battery Performance: 2000 cycles(80%DOD)or2years after manufacture; ·Generator: 18 months after manufactureor 1500 hours running time;
General Specification
Model| AIO-20
System Rated Output Power| 20 kVA
Rated Output Voltage| 400V/230V@50Hz/60Hz,3ph.(According to customer
requirements)
Min.Battery Storage Capacity| 20 kWh
Max.Battery Storage Capacity| 40 kWh
Output Terminals| Copper terminals & CEE 32A/5P Socket
Expand Dimension(WDH)| 590063507000mm
Loading Dimension(WDH)| 395022802230mm
Net.Weight| 2800kg
Loading Capacity of 40’HC| 3 units
Discharge Temperature Range| -20℃~50℃
SOLAR PANEL MAX. POWER:5040 W With HIGH EFFICIENCY UP TO21%~!!
GENERATOR RATED POWER:10kW With LOW CONSUMPTION DOWN TO 3.7L/H~!!
INTELLIGENT INVERTER ONE PIECE FOR SOLAR & BATTERY & GRID & GENERATOR
Fits the practical application & guaranteed by high-quality manufacturing technology
Generator Set
Prime Power | 13 kVA |
---|---|
Fuel Consumption | 3.7 L/h@100% load |
Fuel Type | Diesel(Nature Gas Engine for option) |
Fuel Tank Capacity | 24 hours |
Base Functions | Automatic Start-up / Alarm / Automatic Stop / Emergency Stop / |
Load Management
Solar Panel
Maximum Power| 420W
Power Tolerance| 0~+5W
Qty.| 12pcs
Energy storage battery
Cell Type| LFP(LiFePO4)
Pack Model| MF51100D
Pack Capacity| 5 kWh
Pack Rated Voltage| 51.2 VDC
Discharge Depth| 90%
Charger/Discharge Current| 97.7 A(1.0C)
Battery Rack Voltage| 43.2V~59V
Rated Cycle Life| ≥2000(80% DOD)
Hybrid Inverter System
Solar Controller| MPPT4 ways
AC Voltage Range| 380~415Vac
Max.Charge/Discharge Current| 420A
Max.Conversion Efficiency| 97.6%
Rated Output Power| 20kVA(0.8leading~0.8lagging)
Wind Turbine
Rated Power| 400W2pcs
Stand Running Condition| Start-up wind speed>2m/s;Rated wind
speed>10m/s;Survival wind speed<45m/s
Options
Engine | Alternator | Fuel System | Hybrid Power Station |
---|---|---|---|
Water Jacket Preheater Oil PreheaterOil manual pump | PMG excitation Space | ||
heater Winding temperature measuring | 12 / 24 hour base tank Bunded fuel tank |
External fuel tank Automatic fuel feedingSwitch between external tank and base tank (three-way valve)| Deepsea, ComAp, Smartgen etc. controllerTrailerTools with the machine
Basic Logic
Power Priority | Highest | Secondary | Back Up |
---|---|---|---|
PV | Battery | Generator | |
Functions | Take load/charge | Take load | Take load/charge |