WiZ 9290041114 Smart Outdoor Camera Installation Guide
- September 9, 2024
- wiz
Table of Contents
9290041114 Smart Outdoor Camera
“`html
Specifications:
- Model: WiZ Outdoor Camera NAM model9290041114
- Excluded: SMART OUTDOOR CAMERA Installation manual
- MicroSD card (excluded)
- IP Rating: IP54
- Power Input: 5Vdc +/- 5%
- Power Consumption: 2A/10W
- Radio Frequency: 2400MHz-2483.5MHz
- Wi-Fi Range: 150 meters
- Dimensions: 97mm x 67mm x 35mm
- Color: Black
- Housing Material: PC
- Net Weight: 120g
Product Usage Instructions:
Installation:
-
Ensure the installation area complies with IP54 rating for wet
locations. -
Mount the camera securely using the provided flying cable and
connectors. -
Make sure to provide proper strength relief for the cables with
a minimum strength of 50N.
Power and Connectivity:
-
Connect the camera to a power source with a voltage of 5Vdc and
a current of 2A. -
Ensure the Wi-Fi communication range is within 150 meters for
optimal connectivity.
Environmental Considerations:
-
Operate the camera within a temperature range of -20°C to
+45°C. -
Store the camera in temperatures between -40°C to +70°C.
-
Maintain operation relative humidity between 0% to 90% and
storage relative humidity between 24hrs at +70°C with no
condensation and 24hrs at -40°C with 95%RH with no
condensation.
Maintenance:
-
Comply with hazardous substances regulations such as ROHS and
REACH. -
Ensure the camera is protected against UV exposure to maintain
longevity.
Frequently Asked Questions (FAQ):
1. Is a MicroSD card included with the camera?
No, the MicroSD card is not included and needs to be purchased
separately for storage purposes.
2. What is the Wi-Fi communication range of the camera?
The Wi-Fi communication range of the camera is 150 meters under
line of sight conditions.
3. What is the warranty period for the camera?
The camera comes with a warranty of 2 years from the date of
purchase.
“`
WiZ Outdoor Camera NAM model9290041114
Excluded
SMART OUTDOOR CAMERA
Installation manual
1
MicroSD card (excluded)
7
Ø6mm/ 0.24in
x 3 (ST4.2 x 30) 2
3
x 3 (Ø6 x 30)
. 4…. .
. .
. . .
. . .
. . . .
. . .
. . . .
. . .
. . . .
. . .
. . . .
. . .
. .
IP20
8
9
5
6
QR 16mm x 16mm (placed by SGS)
10
IP2.0 .
.
. .
.
.
.
.
.
.
.
.
. . …
.
.
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
.
.
. …
.
.
.
.
.
.
.
.
.
30mm/ 1.2in
11
12
Ø6
13
14 IP20
.
.
…
.
..
.
.
…
.
..
.
.
…
.
..
.
.
…
.
..
.
.
…
.
..
.
.
…
.
..
.
.
.
Classified
Electrical information: Input voltage Current/Power Over voltage protection
Protection against electric shock Radio Frequency
Radio Transmission power
Wi-Fi communication range
5Vdc +/- 5% 2A/10W 12Vdc max. Class 2, SELV 2400MHz-2483.5MHz
20dBm for NAM 16dBm for E.U. 150meters
RMS=3.3W, peak=6.2W (Max) EU: 1-13 channel NAM: 1-11 channel Line of Sight
Mechanical information:
Overall Dimension (main body) Color Housing Material Net weight per piece
Ingress Protection Connection Connectors Strength relief
97mmx 67mm x35mm Black
PC 120g IP54, Wet location Flying cable, 30 cm PH2.0 2P, PH2.0 6P >= 50N
Environment and approbation: Operation temp Storage temp Operation relative
humidity
Storage relative humidity
Approbation Hazardous substances compliance Warranty Anti-UV
-20…+45 -40…+70 0/1090%RH, +4580%RH no condensation +70 24hrs / -40 24hrs / +70 95%RH 24hrs no condensation WFA, UL, CB, RED, FCC/IC ROHS, REACH compliant
2 years 1.Optical parts (Lens cover, light sensor etc.): – E<2, –
transmissivity degradation <2%, – Reflectivity degradation<2%) , – No impact
for image quality and day/night scenes switch. 2.Other parts: E<6;
3.Significant reduction in mechanical strength and pulverizing, embrittling,
peeling, obvious color change are not allowed.
Pa g e 2|7
Classified
Others LED indicator Button SD card Interface 8pin
Startup time
Red, Green Tack switch Micro-SD card support up to 1TB UART_TX(white),
UART_RX(orange), GPIO_01(green), GPIO_02(purple), GND(black), USB_DP(blue),
USB_DM(brown), 5V(red) 1min cold start at -20,
45seconds at 25
Not included
P a g e 3 |7
Classified
Pa g e 4|7
Classified
Important notes for design-in: 1) The WiZ camera module works only with WiZ V2
app. 2) The WiZ camera module should be powered with a Limited Power Supply
(LPS) only according to UL IEC 62368 or equivalent. Please consult WiZ for
more details if necessary. 3) It is the manufacturer’s responsibility of end
products to ensure the full compliance of the final integration applications
(i.e end products). 4) Please clean the camera lens gently with a cotton cloth
and avoid touching the lens with hands directly to ensure clear view. 5)
Please regularly clean the dust on microphone and speaker to ensure 2-way
audio quality. 6) The WiZ camera module does not provide third-party
monitoring or emergency response. It is the user’s responsibility to
determinate the appropriate response. 7) The WiZ camera module is limited to a
user’s own, private residential use. 8) The user is responsible to comply with
privacy and other applicable laws.
P a g e 5| 7
Classified
(WEEE dustbin logo and explanation)
Simplified EU Declaration of Conformity Hereby, Signify declares that the
radio equipment type WiZ camera module is in compliance with the Directive
2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: www.wizconnected.com. Simplified UK
Declaration of Conformity Hereby, Signify declares that the radio equipment
type WiZ camera module is in compliance with the Radio Equipment Regulations
2017 (S.I. 2017/1206). The full text of the UKCA declaration of conformity is
available at the following internet address: www.wizconnected.com
FCC compliance statement This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: – Reorient or relocate the receiving antenna. –
Increase the separation between the equipment and receiver. – Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. – Consult the dealer or an experienced radio/TV
technician for help. Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
Pa g e 6|7
Classified
This device complies with FCC RF exposure limits set forth for an uncontrolled
environment. This device should be installed and operated with minimum
distance 20cm (8 inches) between the device and user body.
ISED compliance statement
This device complies with Innovation, Science and Economic Development Canada
(ISED) licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that
may cause undesired operation. This equipment complies with ISED radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance 20cm between the
radiator and your body. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter. Cet appareil est
conforme à la ou aux normes RSS exemptées de licence pour Innovation, Science
et développement économique Canada. Le fonctionnement est soumis aux deux
conditions suivantes: (1) ce dispositif ne peut pas causer d’interférence
nocive, et (2) ce dispositif doit accepter toute interférence reçue, y compris
les interférences pouvant causer un fonctionnement indésirable. Cet équipement
respecte les limites d’exposition aux rayonnements ionisants fixées pour un
environnement non contrôlé. Cet équipement doit être installé et utilisé avec
une distance minimale de 20cm entre le radiateur et votre corps. Cet émetteur
ne doit pas être localisé ou fonctionner en conjonction avec une autre antenne
ou un autre émetteur.
P a g e 7| 7
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>