BEA LZR-FLATSCAN 3D SW Door Control Wiring Matrix Owner’s Manual

September 8, 2024
BEA

BEA LZR-FLATSCAN 3D SW Door Control Wiring Matrix

Specifications

  • Model: LZR-FLATSCAN SW / LZR-FLATSCAN 3D SW
  • Manufacturer: BEA, Inc.
  • Control Harness: 20.5433
  • Power Input: 24V DC

Product Usage Instructions

Installation Requirements
Before starting the installation process, ensure that:

  • Installation and service technicians are certified appropriately.
  • Risk assessments are conducted after each installation.
  • Compliance with local, national, and international regulations is verified.
  • All necessary signage and warning labels are in place.

Wiring Instructions
Refer to the provided wiring matrix for connecting the control harness to compatible door/gate systems.

Power Connection
Connect the power input to a 24V DC power source following the specified wiring connections.

Additional Information
For detailed instructions on specific door/gate systems, refer to the BEA product User’s Guide and OEM manual.

FAQ

  1. Q: What certifications are recommended for installation technicians?
    A: BEA, Inc. recommends AAADM certification for pedestrian doors, IDA certification for doors/gates, and factory training for the specific door/gate system.

  2. Q: What should be verified before starting the installation process?
    A: Verify that all appropriate industry signage, warning labels, and placards are in place, and that technicians are certified and compliant with regulations.

BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose. BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system. Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.

Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code). Verify that all appropriate industry signage, warning labels, and placards are in place.

Control Harness: 20.5433

Control Harness: 20.5433| __| __| __|
| __| __**W| | | |
---|---|---|---|---|---|---|---|---|---|---
POWER 1| O1: N.O.| O1: N.C.| O1: COM| O2: REACTIVATION 2| O2: ACT (COM)| O3: VPB 3| MONITORING 4
Besam ETIK 5| 30.5558| | 15/17| 16/18| Logic Module| 12| 13| Not supported.
Besam MP/CUP| 30.5558| 5| | 4| Logic Module| 4| 3| Not supported.
Besam PowerSwing/EXB| 30.5558| | TB4-29| TB4-26| Logic Module| TB3-20| TB3-21| Not supported.
Besam SM| 30.5558| TB1-7| | 3| Logic Module| 3| 1| Not supported.
Assa Abloy SW 100/200, DITEC HA9 6| 24V+| GND| | EXU-SA 3| EXU-SA1| EXU-SA 1 and 2 (N.C.)| CU-ESD 1| CU-ESD 2| Refer to BEA product User’s Guide and OEM manual.
CONDOR| 30.5558| DMS O| | COMMON N| V and W| COM 16| ACTIVATE 17| Not supported.
DCU DC700
Access Auto. ES500 Quad Systems ES500|
30.5558| CN6 GREEN| | CN6 BLACK| AUX CN7 (AF = 2)| CN2 #3| CN2 #2| Not supported.
Detex BS1000S/UDC100| 30.5558| 5| | 1| J2-3 and 1| 1| 2| Not supported.
Dor-O-Matic| 30.5558| PURPLE| | GRAY| Logic Module| GRAY| YELLOW| Not supported.
Dorma 400/700| 30.5558| SWING| | GND| APPR and GND| GND| TRIGGER| Not supported.
Dorma ED 100/250 7| 1| 3| | 15| 3| 11 (N.C.)| 3| 42| Refer to BEA product User’s Guide and OEM manual.
Gyrotech/Nabco Magnum| 30.5558| 3 VIOLET| | 5 RED| Logic Module| 5 RED| 6 BLACK| Not supported.
Gyrotech/Nabco Opus| 30.5558| 5| | 2| 2 and 4| 2| 3| 1 and 7
Gyrotech/Nabco U19| 30.5558| WHITE 6B| | RED 7| Logic Module| RED 7| 61/62| Not supported.
Gyrotech 300/400 8| 30.5558| WHITE| | RED| Logic Module| RED| BLACK| Not supported.
Horton 4160-3 9| 30.5558| DAUGHTER BOARD| | DAUGHTER BOARD| Logic Module| WHITE| BLACK| Not supported.
Horton 4190 10| 30.5558| 10| | 3| 11 and 2| 3| 2| Not supported.
Horton 5190| +24 VDC| 0 V| CN16 ORANGE (10)| | CN16 YELLOW (9)| CN16 GREEN (8)| CN16 BROWN (7)| CN20: 2 = interior, 3 = exterior CN7 COM| __ CN16 PURPLE (13), BLUE (14)
Hunter HA, DITEC HA8| 30.5558| SAFE 2| | RTN| ACT 2 and return| RTN| ACT| Not supported.
Keane-Monroe K| 30.5558| YELLOW| | WHITE| Logic Module| WHITE| GREEN| Not supported.
LCN Digital / Senior Swing| 30.5558| P2 GREEN| | P2 WHITE| P3 white and green| P6 GRAY| P6 YELLOW| Not supported.
Record 6000/8000 11| 4| 6| | 10| 11| 11 and 12 (N.C.)| 1| 2| Refer to BEA product User’s Guide and OEM manual.
Stanley “L” 12| 30.5558| BLUE| | YELLOW| Logic Module| YELLOW| ORANGE| Not supported.
Stanley MP| 30.5558| 7| | 8| Logic Module| 8| 2| Not supported.
Stanley MC 521 13| 30.5558| TB3-4| | TB3-3| TB5 3 and 4| TB4-3| TB4-4| Refer to BEA product User’s Guide and OEM manual.
Stanley MC 521 Pro and IQ 13| TB4-5| TB4-6| TB3-4| | TB3-3| TB5 3 and 4| TB4-3| TB4-4| Refer to BEA product User’s Guide and OEM manual.
Tucker| 30.5558| | J4-14| J4-8 jumped to 12 & 13| N.C. contact between J4 13 and COM| J4-8 jumped to 12 & 13| J4-10| Not supported.
Tormax 1301Motion| 30.5558| SAFETY A #2| | SAFETY A #1| A6| A5| INPUT C #2| Refer to BEA product User’s Guide and OEM manual.
Tormax TDA| 30.5558| 7| | 8| C4 and C8| 8| 2| Not supported.
Tormax TTX II**| 30.5558| | | 14| 17 and 18| 4| 5| Not supported.
Note 1| If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product.
---|---
Note 2| LE21 function or BR3-X programmed to function 22
Note 3| FS3D only.
Note 4| Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows:| Door Type| System Harness| Control Monitoring
---|---|---
Single| 1 blue + 1 purple| 1st leg
1 blue + 1 purple| 2nd leg
Pair / Dual Egress| 1 blue + 1 purple| 1st leg
1 blue + 1 purple| 2nd leg
Pair / Dual Egress
(independent controls)| 2 blues| 1st control
2 purples| 2nd control

Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance.

Note 5
(BESAM ETIK)| Jump 17+18, if not used.
Note 6
(BESAM SW 100/200)| Set EXU-SA jumper to “Door open/closed” indication. Jump 1+2 on EXU-SA board.
Blanking Potentiometer must be set fully counterclockwise. Auxiliary switch may be used for home switch.
Note 7
(DORMA ED 100/250)| Jump 11+3 on ontrol. Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function “Sr” is set to 1.
Note 8
(GYROTECH 300/400)| Set control to “swing-safe.”
Note 9
(HORTON 4160-3)| Must have daughter board.
Note 10
(HORTON 4190)| PNP harness p/n: 20.5322
Note 11
(RECORD 6000/8000)| Jump 11+12 and 14+15.
Note 12
(STANLEY “L”)| The older Stanley, all metal (silver), “L” shape control does not have stall. A control with stall must be used.
Note 13
(STANLEY MC521 / MC521 PRO)| Jump TB2 2+3 (if not using factory On/Off/Hold Switch).

Tech Support: 1-800-407-4545
Customer Service: 1-800-523-2462