Product Information

Specifications

  • Brand: Elation Professional
  • Model: SIX+ PAR S
  • DMX Channel Modes: 1/3/9/6/9/11/14/14/20
  • IP Rating: IP65

Product Usage Instructions

Safety Guidelines
It is important to follow all safety guidelines provided in the user manual to prevent property damage and injuries. Avoid modifications to the fixture and always adhere to safety instructions.

Installation Guidelines
Ensure the fixture is installed following the provided guidelines. Do not install in maritime/coastal environments as it may cause corrosion and void the warranty.

Accessory Installation
When installing accessories, refer to the user manual for proper instructions. Incorrect installation may affect the performance of the fixture.

Maintenance Guidelines
Regular maintenance is essential for optimal performance. Follow the maintenance guidelines provided to ensure the longevity of the product.

FAQ

  • Can the fixture be used in maritime environments?
    No, the fixture is not suitable for maritime/coastal environments as it may cause corrosion and excessive wear, voiding the warranty.

  • Are there any user-serviceable parts inside the unit?
    No, there are no user-serviceable parts inside the unit. Attempting repairs yourself may void the manufacturer’s warranty.

©2023 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non- ELATION brands and product names are trademarks or registered trademarks of their respective companies.

ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040
323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com
Elation Professional B.V. | Junostraat 2 | 6468 EW Kerkrade, The Netherlands
+31 45 546 85 66 | +31 45 546 85 96 fax | www.elationlighting.eu | info@elationlighting.eu
Elation Professional Mexico | AV Santa Ana 30 | Parque Industrial Lerma, Lerma, Mexico 52000
+52 728-282-7070

DOCUMENT VERSION
Due to additional product features and/or enhancements, an updated version of this document may be available online. Please scan the QR Code with your mobile device or visit www.elationlighting.com for the latest revision/update of this manual, before installation and/or programming.

Date| Document Version| Software Version| DMX Channel Mode| Notes
---|---|---|---|---
11/10/23| 1.0| 1.01| 1/3/9/6/9/11/14/14/20| Initial Release
12/15/23| 1.1| N/C| No Change| Updated Specifications

GENERAL INFORMATION

INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use infor- mation. This device is intended for use by trained personnel only, and is not suitable for private use.

UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories neces-sary to install and operate the device have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

BOX CONTENTS

  • Lense: 22°
  • Power Cable (x1)

CUSTOMER SUPPORT
Contact ELATION Service for any product related service and support needs.
Also visit forums.elationlighting.com with questions, comments, or suggestions.

ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu
REPLACEMENT PARTS please visit parts.elationlighting.com

IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS.

IP65 RATED

The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture. An IP65 rated lighting fixture is designed and tested to protect against the ingress of dust (6), and low-pressure water jets from any direction (5).

NOTE: THIS FIXTURE IS INTENDED FOR TEMPORARY OUTDOOR USE ONLY!
Maritime/Coastal Environment Installations: A coastal environment is seaside adjacent, and caustic to electronics through exposure to atomized salt-water and humidity, whereas maritime is anywhere within 5-miles of a coastal environment.

NOT suitable for maritime/coastal environment installations. Installing this fixture in a maritime/coastal environment may cause corrosion and/or excessive wear to the interior and/or exterior components of the fixture. Damages and/or performance issues resulting from installation in a maritime/coastal environment will void the manufactures warranty, and will NOT be subject to any warranty claims and/or repairs.

Maritime installations require additional preparation, and additional service intervals may be needed given the maritime use. In general, IP ratings presuppose freshwater conditions VS maritime conditions, which are typically more “caustic” to IP fixtures (both internally and externally). A duty-cycle may also be needed when units are not in use. During times of high humidity and colder temperatures, condensation may occur internally so the fixture may require a duty-cycle to bring it up to running temperature, allowing any accumulation of moisture to be expelled via the vent valve. Recommendations can change based on installation environmental circumstances. A waterproof dome or similar device is recommended for use in permanent outdoor installations. When using a dome, refer to manufacturer recommendations for duty-cycle.

NOTE: NOT ALL FEATURES LISTED ARE AVAILABLE ON ALL FIXTURES; THE FOLLOWING INSTRUCTIONS MAY NOT APPLY. CONTACT SUPPORT FOR ADDITIONAL DETAILS.
Exterior Maintenance: Inspect the exterior every 30-days. The unit must be powered off/disconnected. The chassis should be inspected for any signs of contaminants. Inspect optics to determine if the lens is obstructed, then clean optics and chassis accordingly. Based on initial finding, schedule maintenance accordingly, keeping in mind that exterior maintenance will be required. Even if the luminaires are NOT in use, maintenance will still be needed given its location (exterior use). The use of a durable type of wax on the chassis is recommended since it will help prevent contaminant build up. Inspect both power and data lines for any signs of contaminants or corrosion. Periodically reapplying di-electric grease, especially in coastal environments. If any signs of corrosion/contaminants are present, clean thoroughly, and/or replace connectors, then reapply di-electric grease. Typically, this should be done annually, or any time an opportunity presents itself. As a preventive measure, annual replacement of both vent valves is recommended. The vent valve membrane can become contaminated and/or clogged causing improper venting of humidity within the luminaire. Inspect all mounting hardware as a precaution.

Interior Maintenance: Inspect the interior every 30-days. The unit must be powered off/disconnected.

  • Inspect zoom/focus mechanism, clean optics, lubricate linear bearings (Krytox oil) as needed, inspect belts for wear.
  • Inspect all rotating effect wheels, manually rotate them, note any resistance.
  • Inspect all remaining rotating belts for any wear.
  • Inspect all fans, clean as needed, check rotation, check connections.
  • Inspect CMY module, manually move flags and check for signs of resistance, and if needed, clean guide rods first, then reapply a thin layer of grease (moly lube).
  • Clean interior with low-volume compressed air, then clean optics prior to reassembly of head covers.

Although the base has limited moving parts, the pan belt should also be inspected for wear. Remember to always perform an IP test anytime a cover is removed. There is no specific time frame regarding the routine replacement of parts such as belts/stepper motors, PCBs, or LEDs. These items should only be replaced on an as needed bases, except for cooling fans, which should be replaced once the luminaries reach 10,000-hours. This is a prophylactic measure intended to keep the unit running as cool as possible, insuring proper function of all internal components. A complete service breakdown is available, please contact service@elationlighting.com for any needed parts or manuals.

LIMITED WARR ANTY (USA ONLY)

  • A. Elation Professional hereby warrants, to the original purchaser, Elation Professional products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (180 days), from the original date of purchase. This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.
  • B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States. If any product is sent, it must be shipped in its original package and packaging material. No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or damage to any such accessories, nor for the safe return thereof.
  • C. This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional; if the product is damaged because not properly maintained as set forth in the product instructions, guidelines and/or user manual.
  • D. This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
  • E. Elation Professional reserves the right to make changes in design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured.
  • F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product.
  • G. This warranty is the only written warranty applicable to Elation Professional products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.

WARRANTY RETURNS
All returned service items whether under warranty or not, must be freight pre- paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support.

SAFETY GUIDELINES

This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Only qualified and/or certified personnel should perform installation of this fixture and only the original rigging parts included with this fixture should be used for installation. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR-
\(2\)

RISK GROUP 3 – RISK OF EXPOSURE TO ULTRAVIOLET UV RADIATION! FIXTURE EMITS HIGH INTENSITY WAVELENGTH OF ULTRAVIOLET UV LIGHT FROM THE UV COLOR FILTER. WEAR PROPER EYE AND SKIN PROTECTION. AVOID PROLONGED PERIODS OF EXPOSURE TO UV COLOR FILTER. AVOID WEARING WHITE COLOR CLOTHING AND/OR USING UV PAINTS ON SKIN. AVOID DIRECT EYE AND/OR SKIN EXPOSURE AT DISTANCES LESS THAN 10 feet (3m). DO NOT OPERATE FIXTURE WITH DAMAGED/MISSING EXTERNAL COVERS. DO NOT LOOK DIRECTLY INTO THE UV LIGHT AND/OR VIEW UV LIGHT DIRECTLY WITH OPTICAL INSTRUMENTS THAT MAY CONCENTRATE THE LIGHT/RADIATION OUTPUT. INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET UV LIGHT EMITTED FROM THE UV LED.

  • DO NOT TOUCH the fixture housing during operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before serving.
  • DO NOT shake fixture, avoid brute force when installing and/or operating fixture.
  • DO NOT operate fixture if the power cord is frayed, crimped damaged and/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease.
  • NEVER force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace it immediately with a new one of similar power rating.
  • DO NOT block any air ventilation slots.
  • All fan and air inlets must remain clean and never blocked.
  • Allow approx.6’’(15cm) between fixture and other devices or a wall for proper cooling.
  • Always disconnect fixture from main power source before performing any type of service and/or cleaning procedure. Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord.
  • During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time.
  • Consistent operational breaks will ensure the fixture will function properly for many years.
  • ONLY use the original packaging and materials to transport the fixture in for service.

OVERVIEW

ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(4\)

TORQUE SETTINGS FOR SCREWS

CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!
TO CONFIRM THE IP65 INTEGRITY, TEST FIXTURE USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.

IP TEST PARAMETERS

Following any repair or maintenance procedure that requires disassembly of the fixture, use Elation’s IP Tester to confirm the IP integrity of the fixture. The air valve is located on the back panel next to the display screen, as shown in the diagram below. Please contact Elation Service for information regarding the Elation IP Tester, or visit the product information page online at: https://www.elationlighting.com/ip-tester.

CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN PROXIMITY TO THE LENS OF THE FIXTURE WHILE PERFORMING THE TEST!

DE-HUMIDIFICATION: IP65 fixtures operating in high-humidity environments may experience residual fogging or condensation. Such fogging will not affect the fixture, and can be removed using the following procedure: position the unit with the air valve pointing upwards, then open the air valve and run the unit for 1-2 hours after reaching operating temperature. Then, while the fixture is still hot, re-install the air valve and allow the unit to cool down. Please note: this procedure should be performed in a dry, climate- controlled environment. Avoid additional fogging by drying the fixture completely before placing into a road case.

Elation Product| Minimum Value| Maximum Value| Inflation Time| Balance Time| Inspection Time| Leakage
---|---|---|---|---|---|---
Kpa| Psi| Kpa| Psi| S| S| S| Pa
Elation Six+ PAR S| 20| 3| 23| 3| 30| 15| 15| >100

ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(6\)

INSTALLATION GUIDELINES

  • FLAMMABLE MATERIAL WARNING
    Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics.

  • ELECTRICAL CONNECTIONS
    A qualified electrician should be used for all electrical connections and/or installations.

  • MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1 FOOT (0.3 METERS)

  • MINIMUM DISTANCE OF FLAMMABLE MATERIALS FROM THE SURFACE IS 1.6 FEET (0.5 METER)

  • MAXIMUM AMBIENT TEMPERATURE 113° F (45°C)

  • DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

  • Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.

  • Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.

  • Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas where unauthorized personnel might reach the fixture by hand.

  • NEVER stand directly below the fixture(s) when rigging, removing, or servicing.

  • Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable.

  • Allow approximately 15 minutes for the fixture to cool down before serving.

CLAMP INSTALLATION
This device features a mounting clamp attachment point built into the mounting bracket, as well as a safety cable attachment point located on the rear face of the fixture above the control panel.

OMEGA BRACKETS WITH CLAMP INSTALLATION
Insert the Omega Brackets into the matching holes on the yoke. Secure the Omega Brackets to the fixture by turning each quick-lock fastener ¼ turn clockwise; making sure the fastener is completely locked. Omega Brackets can be installed into the fixture base as illustrated below.ELATION-51210-Six-
Plus-Par-S-Outdoor-LED-PAR- \(7\)

SAFETY CABLE
ALWAYS ATTACH AN APPROPRIATELY RATED SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR-
\(8\)

MOUNTING THE FIXTURE ON A TRUSS USING CLAMPS WITH OMEGA BRACKETS
When mounting the fixture to a truss, be sure to secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M10 or M12 screw fitted through the center hole of the Omega Brackets. The fixture provides a built-in rigging point for a SAFETY CABLE (not included). Be sure to use the designated rigging points for the safety cable and never secure a safety cable to a carrying handle.

FIXTURE INSTALLATION
The Elation SIX+ PAR S is fully operational in three different mounting positions, hanging upside-down, mounted sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 0.2m (7.9in.) away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Never use the carrying handles for secondary attachment.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR-
\(9\)

FALLING FIXTURES CAN CAUSE SEVERE INJURY OR SERIOUS EQUIPMENT DAMAGE! FOR THIS REASON, FIXTURES SHOULD BE INSTALLED AND INSPECTED ONLY BY QUALIFIED PERSONNEL. DO NOT INSTALL THE UNIT IF YOU LACK THE QUALIFICATIONS TO DO SO, OR IF YOU HAVE DOUBTS ABOUT THE SAFETY AND SECURITY OF THE INSTALLATION SETUP OR LOCATION! ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.

POTENTIAL INTERNAL FIXTURE DAMAGE FROM EXTERNAL SOURCES OF LIGHT BEAMS
External sources of light beams from direct sunlight, lighting moving head fixtures, and lasers, which are focused directly towards the exterior housing and/or penetrate the front lens opening of ELATION lighting fixtures, can cause severe internal damage including burning to optics, dichroic color filters, glass and metal gobos, prisms, animation wheels, frost filters, iris, shutters, motors, belts, wiring, discharge lamps, and LEDs. This issue is not specific only to ELATION lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed. Contact ELATION Service for more details.

DO NOT EXPOSE THE FIXTURE AND/OR FRONT LENS OPENING TO LIGHT BEAMS FROM DIRECT SUNLIGHT, OTHER LIGHTING MOVING HEAD FIXTURES, AND LASERS WHILE UNPACKING, INSTALLATION, USE, AND EXTENDED IDLE TIMES OUTDOORS. DO NOT FOCUS A LIGHT BEAM FROM ONE LIGHTING FIXTURE DIRECTLY TOWARDS ANOTHER.ELATION-51210-Six-Plus-
Par-S-Outdoor-LED-PAR- \(10\)

ACCESSORY INSTALLATION

FROST LENS

  1. Slide lock levers inward to retract the locking tabs.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(11\)
  2. Install the Frost Lens by angling the bezel groove of the Frost Lens into the tab and levering it into place.
  3. With the Frost Lens installed, slide levers outward to lock it in place.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(13\)

GEL FR AME

  1. Align the 4x holes on the Holder with the face of the fixture, and secure it with 4x philips head screws.
  2. Flip up the retaining clip located near the top of the Holder.
  3. Slide the Gel Frame into place. Then close the latch.
  4. Return the retaining clip to the original position.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(16\)

BARNDOOR

  1. Flip open the retaining clip located near the top of the lens.
  2. Slide the barndoor into place in front of the Gel Frame.
  3. Return the retaining clip to the original position to lock the barndoor in place.ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(20\)

REMOTE DEVICE MANAGEMENT (RDM)
NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for lighting, and allows the DMX systems of the fixtures to be modified and monitored remotely. This protocol is ideal for instances in which a unit is installed in a location that is not easily accessible.
With RDM, the DMX512 system becomes bi-directional, allowing a compatible RDM enabled controller to send out a signal to devices on the wire, as well as allowing the fixture to respond (known as a GET command). The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit’s display screen, including the DMX Address, DMX Channel Mode, and Temperature Sensors.

FIXTURE RDM INFORMATION:

Device ID| Device Model ID| RDM Code| Personality ID
---|---|---|---
30| 48| 0000-FFFF| 22A6


Please be aware that not all RDM devices support all RDM features, and therefore it is important to check beforehand to ensure that the equipment that you are considering includes all of the features that you require.
The following parameters are accessible in RDM on this device:

[0x0122] Default Slot Value [0x0400] Device Hours
[0x00C2] Boot Software Version Label [0x0015] Comms Status
[0x00C1] Boot Software Version ID [0x0031] Status ID Description
[0x0070] Product Detail ID List [0x0032] Clear Status ID
[0x0030] Status Messages [0x0401] Lamp Hours
[0x0011] Proxied Device Count [0x0402] Lamp Strikes
[0x0200] Sensor Definition [0x0403] Lamp State
[0x0201] Sensor Value [0x0404] Lamp Mode
[0x0080] Device Model Description [0x0405] Device Power Cycles
[0x0081] Manufacturer Label [0x0500] Display Invert
[0x0082] Device Label [0x0501] Display Level
[0x00E0] DMX Personality [0x0603] Realtime Clock
[0x00E1] DMX Personality Description [0x1010] Power State

SYSTEM MENU

The fixture includes an easy to navigate system menu. The control panel display is located on the rear panel of the fixture (see image below) and provides access to the main system menu, where all necessary system adjustments are made to the fixture. During normal operation, pressing the MODE button once will access the fixture’s main menu. Once in the main menu you can navigate through the different functions and access the sub-menus with the DOWN and UP buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the DOWN and UP buttons to adjust the field. Pressing the ENTER button once more will confirm the setting. Exit the main menu at any time without making any adjustments by pressing the MODE button.
The display screen will shut OFF automatically after 30 seconds of inactivity. To turn the display back on, press and hold the MODE button for 10 seconds.

AN ELATION C-LOADER II CAN ALSO BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. To order this device, please contact Elation Support for further details.
Detailed instructions can be found online at www.elationlighting.com.
ELATION SERVICE USA – Monday – Friday 8:00am to 4:30pm PST
323-582-3322 | Fax 323-832-9142 | support@elationlighting.com
ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET
+31 45 546 85 63 | Fax +31 45 546 85 96 | support@elationlighting.eu

MAIN MENU OPTIONS / VALUES (Default Settings in BOLD )
DMX DMX Address
DMX Mode 1CH Dimmer
3CH RGB
9CH RGB Extended
6CH Color
9CH Color & Dimmer
11CH CMY
14CH CMY Extended
14CH Standard
20CH Extended
SixPar Emulation (See Emulated DMX Traits on page 28) 6 Channel

7 Channel
8 Channel
12 Channel
No DMX Status| Hold Last|
Fade to Black|
Standalone|
Protocol| Select Signal| DMX / Aria In – DMX Out / DMX In – Aria Out
Aria| Aria Channel| 0 -14
Control| Manual Control| Dimmer 0-255| 000% – 100%
Red 0-255| 0 – 255
Green 0-255| 0 – 255
Blue 0-255| 0 – 255
Mint 0-255| 0 – 255
Amber 0-255| 0 – 255
UV 0-255| 0 – 255
CCT| 2400K – 8500K (Default = 6000K ).
Green Shift| -100% ~ +100% (Default = 0 )
Virtual Color| See Color Macros
Primary| On / Off|
Secondary| On / Off|
Self Test| All|
Dimmer|
Color|
Settings| Dim Modes| Standard|
Stage|
TV|
Architectural|
Theatre|
Stage 2|
Dim Speed| 0s – 10s (Default = 0.1s )
Dim Curves| Linear|
Square|
Square Inverse|
S-Curve|
LED Refresh Rate| 900Hz – 1500Hz, 2500Hz, 4000Hz, 5000Hz, 6000Hz, 10KHz, 15KHz,

20KHz, 25KHz (Default = 1200 Hz )

LED Power Limit| 50%|
60%|
70%|
80%|
90%|
100%|
Display| Screen Delay| 10s – 5min (Default = 1 min )
Screen Lock| Off , 10s – 5 min, Key Lock
Rotate Display| Yes / No / Auto
Reset Defaults| Yes / No|

MAIN MENU OPTIONS / VALUES (Default Settings in BOLD )
Information Time
Total Run Time
Last Run Time
Temperature Current
Max Resettable
DMX Values Red
Green
Product IDs RDM UID
Error Logs Fixture Errors
Software Version Vx.x
Service (Passcode = 050) Aria Activation
Calibration Red 000 – 255
Green 000 – 255
Blue 000 – 255
Mint 000 – 255
Amber 000 – 255
UV 000 – 255
Reset Last Run Yes / No
Reset Error Logs Yes / No

NOTE ON EMULATION DMX TRAITS (see page 28)
To ensure the SIX+ PAR S can be integrated seamlessly alongside original SixPar fixtures, great care has been taken to ensure that the new LED array colors match the original. A unique SixPar Emulation DMX mode has been developed, so that the new fixtures can be controlled with the same DMX mapping as the original. The color mixing has also been calibrated to virtually emulate the White LED included in the SixPar array and an output limit master setting has been added so your new lights don’t overpower any older fixtures in the rig.

DIMMER MODES & CURVES

ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(22\) ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR-
\(23\)

DMX TRAITS

Dim. 1CH| RGB 3CH| RGB

Ext. 9CH

| Color 6CH| Color & Dim. **9CH| CMY 11CH| CMY**

Ext. 14CH

| Std. 14CH| Ext. 20CH| DMX

Values

| Function| Snap| Default Value
---|---|---|---|---|---|---|---|---|---|---|---|---
1|  | 1|  | 1| 1| 1| 1| 1| 0-255| Dimmer|  | 0
Intensity 0 → 100%
 |  | 2|  | 2| 2| 2| 2| 2| 0-255| Dimmer Fine|  | 0
Fine Intensity Control
 |  | 3|  | 3| 3| 3| 3| 3|  | Shutter/Strobe|  | 50
0-31| Shutter closed
32-63| No function (shutter open)
64-95| Strobe effect slow to fast
96-127| No function (shutter open)
128-159| Pulse-effect in sequences
160-191| No function (shutter open)
192-223| Random strobe effect slow to fast
224-255| No function (shutter open)
 | 1| 4| 1| 4|  |  | 4| 4| 0-255| Red|  | 0
0 → 100%
 |  | 5|  |  |  |  |  | 5| 0-255| Red Fine|  | 0
Fine Adjustment
 | 2| 6| 2| 5|  |  | 5| 6| 0-255| Green|  | 0
0 → 100%
 |  | 7|  |  |  |  |  | 7| 0-255| Green Fine|  | 0
Fine Adjustment
 | 3| 8| 3| 6|  |  | 6| 8| 0-255| Blue|  | 0
0 → 100%
 |  | 9|  |  |  |  |  | 9| 0-255| Blue Fine|  | 0
Fine Adjustment
 |  |  | 4| 7|  |  | 7| 10| 0-255| Amber|  | 0
0 → 100%
 |  |  |  |  |  |  |  | 11| 0-255| Amber Fine|  | 0
Fine Adjustment
 |  |  | 5| 8|  |  | 8| 12| 0-255| Mint|  | 0
0 → 100%
 |  |  |  |  |  |  |  | 13| 0-255| Mint Fine|  | 0
Fine Adjustment
 |  |  | 6| 9|  |  | 9| 14| 0-255| UV|  | 0
0 → 100%
 |  |  |  |  |  |  |  | 15| 0-255| UV Fine|  | 0
Fine Adjustment
 |  |  |  |  | 4| 4|  |  | 0-255| Cyan|  | 0
0 → 100%
 |  |  |  |  |  | 5|  |  | 0-255| Cyan Fine|  | 0
Fine Adjustment
 |  |  |  |  | 5| 6|  |  | 0-255| Magenta|  | 0
0 → 100%
 |  |  |  |  |  | 7|  |  | 0-255| Magenta Fine|  | 0
Fine Adjustment
 |  |  |  |  | 6| 8|  |  | 0-255| Yellow|  | 0
0 → 100%
 |  |  |  |  |  | 9|  |  | 0-255| Yellow Fine|  | 0
Fine Adjustment
 |  |  |  |  | 7| 10| 10| 16|  | Variable CCT|  | 0
0-23| Open
24-85| 2400K → 8500K (See Sheet)
86-255| 8500K
 |  |  |  |  | 8| 11| 11| 17|  | CCT Cross Fade| X| 0
0| CCT
255| Color Mix

Dim. 1CH| RGB 3CH| RGB

Ext. 9CH

| Color 6CH| Color & Dim. **9CH| CMY 11CH| CMY**

Ext. 14CH

| Std. 14CH| Ext. 20CH| DMX

Values

| Function| Snap| Default Value
---|---|---|---|---|---|---|---|---|---|---|---|---
 |  |  |  |  | 9| 12| 12| 18|  | Color|  | 0
0| Open
1-179| Virtual Swatch Book (See Table)
 | Color Scroll
180-201| Clockwise Fast → Slow
202-207| Stop
208-229| Counter-clockwise Slow → Fast
230-234| Open
 | Random Slots
235-239| Fast
240-244| Medium
245-249| Slow
250-255| Open
 |  |  |  |  | 10| 13| 13| 19|  | Dim Modes| X| 0
0-20| Standard
21-40| Stage
41-60| TV
61-80| Architectural
81-100| Theatre
101-120| Stage 2
 | Dimmer Delay Time
121| 0s
122| 0.1s
123| 0.2s
124| 0.3s
125| 0.4s
126| 0.5s
127| 0.6s
128| 0.7s
129| 0.8s
130| 0.9s
131| 1.0s
132| 1.5s
133| 2.0s
134| 3.0s
135| 4.0s
136| 5.0s
137| 6.0s
138| 7.0s
139| 8.0s
140| 9.0s
141| 10s
 | Idle

Dim. 1CH| RGB 3CH| RGB

Ext. 9CH

| Color 6CH| Color & Dim. **9CH| CMY 11CH| CMY**

Ext. 14CH

| Std. 14CH| Ext. 20CH| DMX

Values

| Function| Snap| Default Value
---|---|---|---|---|---|---|---|---|---|---|---|---
 |  |  |  |  | 11| 14| 14| 20|  | Control| X| 0
0-99| Idle
 | Refresh Rate (Hz)
100| 900
101| 910
102| 920
103| 930
104| 940
105| 950
106| 960
107| 970
108| 980
109| 990
110| 1000
111| 1010
112| 1020
113| 1030
114| 1040
115| 1050
116| 1060
117| 1070
118| 1080
119| 1090
120| 1100
121| 1110
122| 1120
123| 1130
124| 1140
125| 1150
126| 1160
127| 1170
128| 1180
129| 1190
130| 1200
131| 1210
132| 1220
133| 1230
134| 1240
135| 1250
136| 1260

Dim. 1CH| RGB 3CH| RGB

Ext. 9CH

| Color 6CH| Color & Dim. **9CH| CMY 11CH| CMY**

Ext. 14CH

| Std. 14CH| Ext. 20CH| DMX

Values

| Function| Snap| Default Value
---|---|---|---|---|---|---|---|---|---|---|---|---
 |  |  | |  | 11| 14| 14|

20

| 137| 1270| X| 0
138| 1280
139| 1290
140| 1300
141| 1310
142| 1320
143| 1330
144| 1340
145| 1350
146| 1360
147| 1370
148| 1380
149| 1390
150| 1400
151| 1410
152| 1420
153| 1430
154| 1440
155| 1450
156| 1460
157| 1470
158| 1480
159| 1490
160| 1500
161| 2500
162| 4000
163| 5000
164| 6000
165| 10000
166| 15000
167| 20000
168| 25000
169-200| Idle
 | Dimmer Curves
201-210| Dimmer Curve: Linear (Default)
211-220| Dimmer Curve: Square
221-230| Dimmer Curve: Inverse Square
231-240| Dimmer Curve: S-Curve
241-255| Idle

EMULATION DMX TRAITS

6 ch| 7 CH| 8 CH| 12 CH| Value| Function| Snap| Default Value
---|---|---|---|---|---|---|---
1| 1| 1| 1| 0-255| Red|  | 0
0 → 100%
2| 2| 2| 2| 0-255| Green|  | 0
0 → 100%
3| 3| 3| 3| 0-255| Blue|  | 0
0 → 100%
4| 4| 4| 4| 0-255| White|  | 0
0 → 100%
5| 5| 5| 5| 0-255| Amber|  | 0
0 → 100%
6| 6| 6| 6| 0-255| UV|  | 0
0 → 100%
 | 7| 7| 7| 0-255| Master Dimmer|  | 0
Intensity 0 → 100%
 |  |  |  |  | Shutter/Strobe|  |
0-31| Shutter Open
32-95| Strobe effect slow to fast|  |
96-127| No function (shutter open)
128-159| Pulse-effect in sequences
160-191| No function (shutter open)
192-223| Random strobe effect slow to fast
224-255| No function (shutter open)
 |  |  | 9|  | Color Macros| X| 0
0-3| OFF
4-7| RED
8-11| GREEN
12-15| BLUE
16-19| WHITE
20-23| AMBER
24-27| UV
28-31| RED + GREEN
32-35| RED + BLUE
36-39| RED + WHITE
40-43| RED + AMBER
44-47| RED + UV
48-51| GREEN + BLUE
52-55| GREEN + WHITE
56-59| GREEN + AMBER
60-63| GREEN + UV
64-67| BLUE + WHITE
68-71| BLUE + AMBER
72-75| BLUE + UV
76-79| WHITE + AMBER
80-83| WHITE + UV
84-87| AMBER + UV
88-91| RED + GREEN + BLUE
92-95| RED + GREEN + WHITE
96-99| RED + GREEN + AMBER
100-103| RED + GREEN + UV
104-107| RED + BLUE + WHITE
108-111| RED + BLUE + AMBER
112-115| RED + BLUE + UV
116-119| RED + WHITE + AMBER
120-123| RED + WHITE + UV

6 ch| 7 CH| 8 CH| 12 CH| Value| Function| Snap| Default Value
---|---|---|---|---|---|---|---
 |  | | 9| 124-127| RED + AMBER + UV| X| 0
128-131| GREEN + BLUE + WHITE
132-135| GREEN + BLUE + AMBER
136-139| GREEN + BLUE + UV
140-143| GREEN + WHITE + AMBER
144-147| GREEN + WHITE + UV
148-151| GREEN + AMBER + UV
152-155| BLUE + WHITE + AMBER
156-159| BLUE + WHITE + UV
160-163| BLUE + AMBER + UV
164-167| WHITE + AMBER + UV
168-171| RED + GREEN + BLUE + WHITE
172-175| RED + GREEN + BLUE + AMBER
176-179| RED + GREEN + BLUE + UV
180-183| RED + GREEN +WHITE + AMBER
184-187| RED + GREEN + WHITE + UV
188-191| RED + GREEN + AMBER + UV
192-195| RED + BLUE + WHITE + AMBER
196-199| RED + BLUE + WHITE + UV
200-203| RED + BLUE + AMBER + UV
204-207| RED + WHITE + AMBER + UV
208-211| GREEN + BLUE + WHITE + AMBER
212-215| GREEN + BLUE + WHITE + UV
216-219| GREEN + BLUE + AMBER + UV
220-223| GREEN + WHITE + AMBER + UV
224-227| BLUE + WHITE + AMBER + UV
228-231| RED + GREEN + BLUE + WHITE + AMBER
232-235| RED + GREEN + BLUE + WHITE + UV
236-239| RED + GREEN + BLUE + AMBER + UV
240-243| RED + GREEN + WHITE + AMBER + UV
244-247| RED + BLUE + WHITE + AMBER + UV
248-251| GREEN +BLUE + WHITE + AMBER + UV
252-255| RED + GREEN + BLUE + WHITE + AMBER + UV
 |  |  | 10|  | Color Chase Macros| X| 0
0-20| No Function
21-40| 30 Color Chase
41-60| 6 Color Chase
61-80| Color Fade Chase
81-255| No Function
 |  |  | 11| 0-255| Color Chase Macro Speed|  |
Color Chase Speed Slow to Fast
 |  |  | 12|  | Dimming Modes| X| 0
0-20| Standard
21-40| Stage
41-60| TV
61-80| Architectural
81-100| Theatre
101-255| No Function

COLOR TEMPERATURE

ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(24\) ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR-
\(25\)

VIRTUAL COLORS

ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(26\)

MAINTENANCE GUIDELINES

DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!

CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean periodically with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.

MAINTENANCE
Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
Please refer to the following points during routine inspections:

  • A detailed electrical check by an approved electrical engineer every three months, to make sure the circuit contacts are in good condition and prevent overheating.
  • Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out during normal operation, resulting in damage or injury as larger parts could fall.
  • Check for any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could allow for dust to enter into the fixture. Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s).
  • Electric power supply cables must not show any damage, material fatigue or sediments.

SPECIFICATIONS

  • SOURCE
    • (7) x 20W RGBMA+ UV LEDs 30,000 Hour Average LED Life
      May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control and Dimming.
  • PHOTOMETRIC DATA
    • 3200 Total Lumen Output
    • CRI – 93
  • EFFECTS
    • Electronic Dimmer and Strobe
    • Variable 16-bit Dimming Modes and Curves
  • COLOR
    • RGBMA+ UV Color Array
    • CMY Emulation
    • Variable CCT 2400K – 8500K
    • Virtual Gel Swatch Book
  • CONTROL / CONNECTIONS
    • 9 DMX Channel Modes (1ch, 3ch, 9ch, 6ch, 9ch, 11ch, 14ch, 14ch, 20ch)
    • 4 SixPar Emulation DMX Channel Modes (6ch, 7ch, 8ch, 12ch)
    • Manual and DMX Controlled Dimmer and Color
    • 4 Button Control Panel, LED Display
    • RDM (Remote Device Management)
    • 3/5pin DMX and IP65 Locking Power Cable In/Out
  • SIZE / WEIGHT
    • Length: 9.73” (247mm)
    • Width: 7.98” (202.6mm)
    • Vertical Height: 9.67” (245.5mm)
    • Weight: 9.48 lbs / 4.30kg
  • ELECTRICAL / THERMAL
    • AC 100-240V – 50/60Hz
    • 100W Max Power Consumption
    • 5°F to 113°F (-15°C to 45°C)
    • BTU/hr (+/- 10%) 341
  • INCLUDED ITEMS
    • Safety Cable
    • IP65 Locking Power Cable
  • OPTIONAL ITEMS
    • 60° Lens
    • 100° Lens
    • Gel Frame & Holder Kit
    • 7.5” Black Barndoor
  • APPROVALS / RATINGS
    • CE | cETLus(pend) | UL | IP65c| FCC | UKCA

DIMENSION DRAWINGS

Drawings not to scale

ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR- \(27\) ELATION-51210-Six-Plus-Par-S-Outdoor-LED-PAR-
\(28\) ELATION-51210-Six-Plus-Par-S-Outdoor-LED-
PAR- \(29\) ELATION-51210-Six-Plus-Par-S
-Outdoor-LED-PAR- \(30\)

ORDERING INFORMATION

SKU US/EU ITEM DESCRIPTION
SIX201 1237000275
SIX+S WFL 1223200104
SIX+S XFL 1223200105
SIX+S L1060 1223200102
SIX+S L140 1223200103
SIX+S GFK 1621000164
TRIGGER CLAMP N/A
STR527 N/A

ERROR CODES

CODE ERROR
TEMP Temperature Error

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC RADIO FREQUENCY INTERFERENCE WARNINGS & INSTRUCTIONS
This product has been tested and found to comply with the limits as per Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device uses and can radiate radio frequency energy and, if not installed and used in accordance with the included instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following methods:

  • Reorient or relocate the device.
  • Increase the separation between the device and the receiver.
  • Connect the device to an electrical outlet on a circuit different from which the radio receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Energy Saving Matters (EuP 2009/125/EC)
Saving electric energy is a key to help protecting the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals