Banggood XY-SK60 CV Power Supply Voltage Regulator
Overview
Full view VA color LCD screen 60W
NC DC power supply
Constant voltage, constant current, constant power
Third-generation upgrade 120W
simply the all-viewing-angle VA color LCD DC buck-boost power supply •
CC/CV/CW
Supports the standard Modbus protocol for serial communication
Support firmware upgrade anti-backflow Support MPPT solar charging
True third-generation upgraded version
The all-viewing-angle VA color LCD
Colorful LCD with large font
- Visual range: 38*29mm The LCD screen is over 1.8 inches!
- The LCD screen has a reasonable layout with a large, full, rounded font.
- This professional power supply LCD screen has all the features you want!
Third generation upgrade 6A/120W
Simply the all-viewing-angle VA color LCD
Large font color screen!
Note:
The 120W is a conservative power rating. With software support, enabling a
power output of up to 150W. Under optimal cooling conditions, the power output
can reach between 130W and 150W.
Product details
Built-in buzzer
Key prompt alarm prompt
Upgrade the plug and pull terminals
Easy to disassemble and replace.
Anti-backflow function
With an anti-backflow function, it can charge various rechargeable
batteries.
With the MPPT function, it supports MPPT solar charging.
With the MPPT function, it supports MPPT solar charging.
External temperature probes can be connected, supporting over-temperature
protection. Attach the external temperature probe to the battery, and it will
automatically stop charging in case of over-temperature.
Attention:
This product does not have output reverse connection protection. Reversing the
positive and negative terminals of the battery will damage the device.
- Battery charging requires certain professional knowledge.
- Non-professionals are not allowed to charge directly to prevent fire and explosion.
Button Function Introduction
Introduction to Functional Interfaces and Wiring
Complete Set of Complementary Commercial Software
Complete Set of Complementary Commercial Software All Free to Use
Multi-Serial Port Host Software
-
Unlimited Device Connectivity:
The software supports multi-serial port communication, allowing up to 247 devices to be connected to a single serial port. By utilizing multiple serial ports, it enables the control of over a thousand devices in a clustered environment. -
Batch Control:
The software allows for batch control of all devices under a specific account, including voltage, current, switches, and other parameters. This feature greatly improves efficiency by enabling simultaneous manipulation of multiple devices. -
Administrative Accounts:
Management accounts can be added to the system, allowing for more secure and controlled access to voltage and current settings. This ensures that only authorized personnel can make changes to critical parameters, reducing the risk of unauthorized modifications or misuse.
Network control anytime, anywhere
LAN penetration, real-time communication Remote control via an external network, unlimited distance
Support email notifications, cloud record
The product supports firmware upgrades to obtain new functions.
At present, it only supports firmware upgrades through our WiFi module. In
the future, it will also be able to upgrade through our multi-serial port host
computer software (under development). Stay tuned!
Note:
Do not power off during the product upgrade process. If the product upgrade
fails, you can press and hold the power button to power on the product and
force it into the upgrade mode.
Product UI function details
XY -SK120
Instructions for Use
-
Setting Voltage and Current:
On the main Ul, briefly press the VSET button to set the voltage. The LCD will display “SET” in the lower row, and “CV” will flash to indicate that the voltage setting position is selected and blinking. Then, briefly press the SW button or the encoder button to switch the voltage setting position. Adjust the value by rotating the encoder. After the setting is complete, briefly press the VSET button to exit and save. To set the current, briefly press the ISET button, and the setting steps are the same as for voltage. -
Quick Setting of Voltage or Current:
In the system parameter settings UI set the parameter FET to CV or CC. Rotate the encoder on the main Ul to enter the voltage or current setting Ul. Rotate the encoder to quickly set the voltage or current.
-
Input/output voltage display:
On the main Ul, press the SW button briefly to switch between input and output voltage displays. -
Checking power (W)/capacity (Ah)/energy (Wh)/time (h):
On the main Ul, press the encoder button briefly to switch between displaying power (W)/capacity (Ah)/energy (Wh)/time (h)/temperature (°C) in rotation. -
key lock:
On the main Ul, press and hold the encoder button for 2 seconds to lock the set voltage and current to prevent misoperation; press and hold the encoder button for 2 seconds after locking to unlock. -
Data Group Function
This product has a total of 10 data groups from CdO to Cd9. Press and hold the VSET button on the main Ul to access the data group UI- You can press VSET/ISET briefly to switch between constant voltage (CV) and constant current (CC) settings. It supports quick viewing and modification of voltage and current in the data group, as well as SW shift operation.
- After confirming the data group, press and hold the VSET/SW button or press the encoder button briefly to select the desired data group.
Set Ul Parameter Settings
Set Ul Parameter Settings within Data Groups
- Press and hold the ISET button on the main interface to enter the settings menu.
- The first parameter is to select the data group Cdo-9.
- Press VSET briefly to select the next parameter, and press ISET to select the previous parameter. After completing the settings, press and hold the ISET/SW/encoder button to exit the settings interface.
Set Ul System Parameter Settings
- Press and hold the SW button on the main interface to enter the settings menu.
- The first parameter is the buzzer setting (bEP). Press VSET briefly to select the next parameter and press ISET to select the previous parameter.
- After completing the settings, press and hold the SW/encoder button to exit the settings.
Data Group Parameter Settings
- Press and hold the ISET button on the main interface to enter the settings menu.
- The first parameter is to select the data group Cd0-9.
- Press VSET briefly to select the next parameter, and press ISET to select the previous parameter. After completing the settings, press and hold the ISET/SW/encoder button to exit the settings interface.
Introduction to CV/CC/CW Functions
- When the constant power function is not turned on, the power supply only has the functions of constant voltage (CV) and constant current (CC), which automatically switch based on the load;
- When the load current is less than the set constant current value, the power supply is in the constant voltage mode, where the output voltage is the set voltage value CV, and the current is adaptive;
- When the load current exceeds the set constant current value, the power supply automatically enters the constant current mode. At this time, the output current is the set constant current value CC, and the voltage is adaptive;
- After the constant power function is turned on, the constant current value defaults to the maximum value, and the constant voltage value CV serves as the initial voltage (set to a reasonable value based on actual conditions). After the power supply is turned on, the equivalent resistance R of the load is calculated using Ohm’s law R=U/l. Then, the corresponding voltage can be calculated based on the set constant power value using the power formula P=U2/R. At this point, the constant power point algorithm automatically follows, and the constant power is achieved.
Constant Power Switch and Constant Power Value Setting
- Press and hold SW on the main Ul to enter the system set.
- Press ISET/VSET briefly to switch to the “-CP-” constant power switch option. Press ON to enable constant power and OFF to disable it.
- After enabling constant power, press ISET briefly on the main interface to modify the value of constant power.