Notice to Customer
Thank you very much for purchasing our PATLITE product.

  • Request the installation and wiring be performed by a professional contractor if construction work is involved.
  • Prior to installation, read this manual thoroughly before using this product to ensure correct use.
  • After reviewing this manual, if there are any questions regarding this product, please contact the nearest PATLITE office listed on the back cover of this manual.
  • Read this manual carefully prior to installation.
  • Be sure to return this manual to the customer.

Safety Precaution

In order to prevent any damage to the user and other personnel or to assets, note the following: The following symbols classify the following precautions into two categories and explain the level of harm inflicted when caution is disregarded while using this product.
WARNING
Indicates an immediately dangerous condition: failure to follow the instructions may lead to death or serious injury.
CAUTION
Indicates a potentially dangerous condition: failure to follow the instructions may lead to slight injury or property damage.

Safety Precautions

WARNING

  • Make sure the power is off before wiring, repairing, or replacing parts to avoid a short-circuit, electric shock, or burn.
  • Please use this product in a properly maintained
  • condition. (If parts such as the Body or LED Unit are damaged, they should be repaired.)
  • Do not use this product with the lens damaged or removed, or without the head cover in order to avoid an electric shock.
  • If installing this product requires construction work, please ask a specialist in order to avoid electric shock, fire, or personal injury.
  • When this product is used for security purposes, it should be inspected daily. In case a malfunction should occur, it is recommended that you use this product together with other security products.
  • Do not use this product to support your weight while climbing onto a machine. Mount the product so that it is clear of any moving parts – such as a machine cover.

CAUTION

  • Concerning replacement parts, such as LED units, bulbs, or fuse, be sure to use those specified in this manual.
  • For safety, make sure to connect an external fuse to the power source as shown in the wiring example.
  • Do not substitute parts from other products as this may cause a breakdown.

Model Number Configuration

PATLITE LES Signal Tower

Part Names and  Outer Appearance

Parts Name

PATLITE LES Signal Tower - Figure 1

Dimensions

PATLITE LES Signal Tower - Figure 2

Installation

CAUTION

  • The following requirements are necessary for proper installation.
    • Install where no excessive vibration is present.
    • Install on a strong surface.
    • Install in an upright position. (Do not install the Signal Tower sideways or inverted.)

  • This product can only be used indoors. (Do not use it outdoors.)

  • Use a soft cloth moistened with water when the LED Unit or Body must be cleaned up. (Do not use thinner, benzine, gasoline, or oil.)

  • When installing this product, do not use excessive torque, or the product may be damaged.

  • During installation, do not remove the waterproof sheet, it will increase possible water penetration and may cause a malfunction.

  • This product also has mm-thick waterproof packing at the bottom of the pole bracket. However, because installation surface unevenness may cause a lack of waterproofing protection, it is recommended to apply waterproof sealant between the unit and the installation surface to maintain waterproof conditions.

How to Install

  • Drill mounting holes in the wall for L-bracket installation, or in the panel for direct mount installation.
  • Secure the L-bracket with hex bolts and hex nuts (not supplied), or the accessory nuts (supplied).
    *With buzzer models, the alarm can be heard best from the front direction. Therefore, make sure the Signal Tower is facing the correct direction before installation.

PATLITE LES Signal Tower - Figure 3

  • When LES-W type is installed in pole bracket (SZ-60L/T type), Three screws(Pan head screw with flat and spring washer M3x7) are needed. When LES-W type is installed in the Bracket (SZ-014 type), Three screws(M3x6) are needed. (The tightening torque is about 0.59N •m.)

Using this template

  1. Verify the hole positions on the product.
  2. Secure the template onto the installation surface using adhesive tape.
  3. Mark the installation holes using a nail punch, etc.
  4. Drill the holes in the installation surface.
  • Confirm the direction of the nameplate and the wiring route before you drill the holes.

Wiring

Caution

  • Make sure the power is OFF before wiring. A short circuit may damage internal circuits or cause an electric shock.
  • Enough attention shall be paid for wiring because if there is any mistakes in wiring a circuit may break down.
  • Install the external contact fuse on the power supply side as shown in the wiring example in order to prevent bum in case of a wiring error.
  • [100V/220VVAC Type] Do not apply voltage directly to signal wires and common wires. It may damage the circuit.
  • Do not apply voltage directly to the brown wire. It may cause a breakdown.(FB type)
  • Do not pull out the lead wire or push it into the pole or the body.

Caution

  • Simultaneously turn on the external contact for both constant lighting and flashing for the same light (color), may cause another light (color) to light up. To avoid this, provide separate switches for flashing or continuous lighting.
  • When turning on the same function, such as flashing or alarms, for more than one product simultaneously, be sure to use separate external contacts for each product and function.
  • When using both alarms sounds on one product, use separate contacts for the alarms and the lights.

How to perform wiring

  • Turn the power OFF.
  • Make wiring connection according to wiring example.
  • When wiring 5 layers or less, please make wiring connections by increasing or decreasing external contacts in each layer according to wiring example.
  • When using LED units of the same color, calculate the contact current capacity to be equal to the number of the LED units multiplied by the contact capacity for 1 light.  (This is because current passes through one signal line for the LED units of the same color.)
  • When wiring is completed, insulate the end of each unused lead wire with insulation tape.
  • Any questions regarding applications for multiple units, or other special operations, contact your nearest PATLITE Sales Representative before wiring.

[To be recognized as a UL standard.]

  • A fuse for protection of external contact should be installed within 305mm from the connecting point of the power source wire.
  • Use a “Class 2 Circuit” for the power supply source (Type: 24V DC) and be sure to use the fuse and fuse holders authorized by UL, Inc.
  • Use the fuse conforming to the rated current of the machine on which the product was installed. (Example: Class J type fuse)

Wire Color Table

Led Unit

Luminous Color Wire Color
Red Red
Amber Orange
Green Green
Blue Blue
White White

Buzzer (FB Type)

Buzzer Wire color
Buzzer: Continuous Purple
Buzzer2: Intermittent Skyblue
  • Lead wires are only included with the flashing/buzzer option. }
  • Buzzer 1 is priority when connected simultaneously to common with buzzer 2.

External Contact Capacity
External Contact (Transistor) Capacity

Voltage Specifications| 12V AC/DC| AC/DC 24V| AC 100V| AC 220V
---|---|---|---|---
LED Unit
(Per Light)| Current Consumption| Red • Amber: 43.0mA
Green • Blue • White: 24.0mA| Red • Amber: 25.0mA
Green • Blue • White: 14.8mA
Contact Capacity| Is? 100mA, Vs a 30V AC| Isa 50mA, Visa 50V AC
Buzzer| Current Consumption| 40mA
Inrush Current| 2A| 250mA
Contact Capacity| Isa300mA, Vs_Z’50V AC
Power
Supply| Current Consumption| 400mA| 360mA| 40mA| 20mA
Contact Capacity| Isa500mA Vsa30V AC| Isa 500mA Vs a 50V AC| Is a 100mA
Vsa 125V AC| Isa 50mA
Vs a 250V AC
Leakage Current| ILS0.1mA

External Fuse

 Voltage  Fuse Rating
 All Model 250V 1A

3X Use the fuse conforming to the rated current of the machine in which the product was installed. (Example: Class J type fuse)

Wiring Example
LE(L)/LES [Continuous Lighting] Type

PATLITE LES Signal Tower - Figure 4

LME-FB [Continuous Lighting, Flashing/Buzzer] Type

PATLITE LES Signal Tower - Figure 5

Wiring Example (NPN/PNP Transistor drive)

PATLITE LES Signal Tower - Figure 6 Charging LED Unit Position

CAUTION

  • Make sure the power is off before wiring, repairing, or replacing parts to avoid a short-circuit, electric shock, or burn.
  • Do not remove the LED unit forcibly as it may damage the unit.
  • When the center screw is loosened or removed, the LED units become unstable and may separate. Therefore, handle carefully to avoid dama
  • Handle the LED units carefully to avoid warping or damage when changing their positions on the tower.
  • Screwing the head cover too tight may damage it. The recommended torque is about 0.59N-m.

Charging LED Unit Position

  • Turn the power off before changing LED unit positions.

  • Unscrew the head cover and remove the lens.

  • Each LED unit is secured by 2 small snaps of different sizes to ensure that the module is assembled correctly.

  • When changing the number of modules, install a center screw to match the number of tiers.

  • LES-A has the lead wires of the adapted LED module for the factory default color only.
    The LED module of LES-A cannot be adapted, removed, or interchanged.

  • In the case of LES Type, the bottom LED unit can not be removed or interchanged.

PATLITE LES Signal Tower - Figure 7

Volume Adjustment

CAUTION

  • Do not move the lever forcibly as it may damage the volume control.

Volume Adjustment

  • The volume can be adjusted by moving the lever near the bottom of the base to the left or right.
  • The volume is at maximum when the lever is positioned right side. :

PATLITE LES Signal Tower - Figure 8

Specification

Type LE

Tiers| Model| UL Registration Model| Rated Voltage| Power Consumption| Mass| Flash Cycle (fpm)
and sound level| Wire type
/Diameter
---|---|---|---|---|---|---|---
1 Tier| -101(FB)P/W| LE- 01 (FB)P/W| 12V AC/DC| 12,24V Type
Red • Amber
• Blue• White :
0.6W
Buzzer : 0.5W (12V)
1.0W (24V)
100V,220V Type
Red .Amber: 1.0W Green. Blue•White:
0 8W
Buzzer: 1.2W Standby : 3.5W| 0.69kg(P)
0.31 kg(W)| Flashing cycle
FB Type
60 Flashes
per minute
Sound level
FB Type
70„85 dB (1 m)| (12,24V Type)
Black wire
UL1007AWG20
Others
UL1007/AWG22
(100,220V Type)
Power source wire
UL1007AWG20
Lead wire
UL1007AWG22
-102(FB)PNV| LE- 02(FB)P/W| 24V AC/DC
-110(FB)P/W| x| 100V AC| 0.78kg(P)
0.40kg(W)
-120(FB)P/W| x| 220V AC
| -201(FB)PNV| LE-01 (FB)PNV| 12V AC/DC| 0.74kg(P)
0.36kg(W)
-202(FB)PNV| LE- 02(FB)P/W| 24V AC/DC
-210(FB)P/W| x| 100V AC| 0.83kg(P)
0.45kg(W)
-220(FB)PNV| x| 220V AC
3 Tiers| -301(FB)P/W| LE- 01 (FB)PNV| 12V AC/DC| 0.79kg(P)
0.41 kg(W)
-302(FB)P/W| LE- 02(FB)P/W| 24V AC/DC
-310(FB)P/W| x| 100V AC| 0.88kg(P)
0.50kg(W)
-320(FB)P/W| x| 220V AC
4 Tiers| -401(FB)PNV| LE- 01 (FB)P/W| 12V AC/DC| 0.84kg(P)
0.46kg(W)
-402(FB)P/W| LE- 02(FB)P/W| 24V AC/DC
-410(FB)P/W| x| 100V AC| 0.93kg(P)
0.55kg(W)
-420(FB)P/W| x| 220V AC
5 Tiers| -501(FB)P/W| LE- 01 (FB)PNV| 12V AC/DC| 0.89kg(P)
0.51 kg(W)
-502(FB)P/W| LE- 02(FB)P/W| 24V AC/DC
-510(FB)P/W| x| 100V AC| 0.98kg(P)
0.60kg(P)
-520(FB)PAN| x| 220V AC

Type LEL

Tiers| Model| UL Registration Model| Rated Voltage| Power Consumption| Mass| Flash Cycle (fpm) and sound level
Wire type| /Diameter
---|---|---|---|---|---|---|---
1 Tier| -102(FB)W| LEL-_02(FB)W| 24V AC/DC| Red • Amber Green • Blue • White: 0.6W
Buzzer: 1.0W| 0.31kg| FB Type
Flashing cycle
60 Flashes per minute
Sound level
70-45 dB (1m)| UL1007/AWG22
2 Tiers| -202(FB)W| 0.36kg
3 Tiers| -302(FB)W| 0.41kg
4 Tiers| -402(FB)W| 0.45kg
5 Tiers| -502(FB)W| 0.51 kg

Type LES

Tiers| Model| UL Registration Model| Rated Voltage| Power
Consumption| Mass| Wire type
/Diameter
---|---|---|---|---|---|---
1 Tier| -102A(W)| LES-_02A(W)| 24V AC/DC 0.50kg 0.62kg| Red • Amber • Green White: Blue • 0.6W| 0.07kg(W)| UL1007/AWG20
2 Tiers| -202A(W)| 0.53kg 0.10kg(W)
3 Tiers| -302A(W)| 0.56kg 0.13kg(W)
4 Tiers| -402A(W)| 0.59kg 0.16kg(W)
5 Tiers| -502A(W)| 0.19kg(W)

  • This product is recognized as a UL standard. (12V, 24V AC/DC type)
    For recognition as a UL standard;
    – Use on a flat surface with a Type 1 Enclosure.
    – Maximum surrounding air temperature is at 60°C.

  • This product conforms to EN standards and shows the CE Marking. (12V, 24V AC/DC type)
    This product has been tested and found to comply with the limits for a Class A device, pursuant to EMC DIRECTIVE.
    These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
    This product must not be used in residential areas.

Caution

  • PATLITE Corporation disclaims all liability for any malfunction or damage occurring as a result of handling contrary to the instructions, cautions, and warnings mentioned in this manual.
  • Specifications may change without notice due to continual product improvement.

PATLITE Corporation
PATLITE Corporation Head office http://www.patlite.com/
PATLITE (U.S.A.) Corporation http://www.patlite.com/
PATLITE Europe GmbH XGermany 9 WM http://www.patlite.eu/
PATLITE (SINGAPORE) PTE UTD # http://wwwpatlite.com/
PATLITE (CHINA) Corporation B http://www.patlite.cn/
PATLITE KOREA CO.,LTD. B http://www.patlite.co.kr/
PATLITE TAIWAN CO., LTD. B http://www.patlite.tw/
PATLITE (THAILAND) CO.,LTD. § W http://www.patlite.co.th/

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PATLITE User Manuals

Related Manuals