Specifications:
- Product: Ambiane MP111 Pendant Remote
- Version: 1.2
- Installation: Must be done by a qualified electrician
- Power Supply: Primary and Secondary connections
- Control Methods: DMX 512, DALI 0-10V
FAQ
Q: Can I install the Ambiane MP111 Pendant Remote by myself?
A: No, installation must be done by a qualified electrician in compliance with electrical codes.
Q: How do I set the operation mode for controlling the fixture?
A: Set the DIP switch on the control unit according to your desired operation mode (DMX 512 or DALI 0-10V).
Attention
- The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
- The unit was designed for indoor use only.
- This unit falls under protection class III.
- Do not install the unit near highly inflammable liquids or materials.
- Do not allow anything to rest on the unit.
- Do not install the unit near an open flame.
- Do not install the unit in dirty, dusty or badly ventilated location.
- Avoid looking directly into the light beam at close range!
- A ceiling (structure) intended for installation of the unit(s) must safely hold at least 5 times the weight of the unit(s) fastened on it.
- The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m.
- Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment – Immunity requirements.
- Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements according to class B.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Fixture exterior view
Installation
- The Ambiane MP111 Pendant Remote must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.
- Always switch off power supply of the control unit before connecting or disconnecting the control unit or the light unit.
- The lower ceiling (or another structure) intended for installation of the Ambiane(s) MP111 Pendant Remote must safely hold at least 5 times weight of the Ambiane(s) MP111 Pendant Remote placed on it.
-
Fasten the control unit (1) on the ceiling by means of two holes in the housing of the control unit.
-
Fasten the ceiling plate M6i (3) to the lower ceiling.
-
Screw the spherical cap (4) with the hanging wire (6) to the ceiling plate M6i (3).
-
Drill the hole (diameter of 8mm) in the lower ceiling for the LED unit supply cable (7). If you wish to have the LED unit supply cable (7) parallel with the hanging wire (6), the distance between the hanging wire and the LED unit supply cable should be 34 mm.
-
Secure the LED unit supply cable (7) above ceiling against loosing from the control unit (1).
-
Install the terminal block (9) on the supply cable connect it to the PCB RB 3729 of the control unit (1).
-
Install the terminal block (10) on the DMX cable and connect it to the PCB RB 3729 of the control unit (1).
-
Install the terminal block (11) on the LED unit cable (7) and connect it to the to the PCB RB 3729 of the control unit (1).
-
Install another terminal block on cables according to requirements of current installation.
Example of connection:
LED unit connection
Connector | + | A | B | – |
---|---|---|---|---|
Function | LEDs + | Data A | Data B | LEDs – |
Colour of wire | Red | White | Blue | Black |
Primary power connection****
Connector | Vcc | 0V |
---|---|---|
Function | Power + | Power – |
Secondary power connection****
Connector | Vcc | 0V |
---|---|---|
Function | Power + | Power – |
Recommended diameters of conductors with respect to distance between the Control unit and the power supply (e.g. Ambiane Power HP):****
Distance/cable length | 25 m | 50 m | 75 m | 100 m |
---|---|---|---|---|
Diameters of conductors | 0.5 mm2 | 1 mm2 | 1.5 mm2 | 2 mm2 |
DMX connection****
Connector | D+ | D- | 0V |
---|---|---|---|
Function | Data + | Data- | Data ground(shielding) |
0-10V connection****
Connector | D+ | 0V |
---|---|---|
Function | +10V | 0V |
DMX connectors are used for 0-10V control
The primary power input serves for a standard power (e.g. Ambiane Power HP).
The secondary power input serves for a backup power (in case that primary
power failed).
If both power inputs are under voltage, the primary power has a priority and
the secondary power is disabled. In case of primary power loss, the secondary
power is enabled.
If the fixture is supplied via the secondary power, the light output of the
fixture is a white colour 3200K (for RGBW, TW and TD version only).
Max. operating time for secondary power is 3 hours (max. power consumption is
reduced to 20 W).
- Set the DIP switch (12) according to your operation mode. This DIP switch is accessible by aperture (18) in the cover of the control unit (1).
The fixture can be controlled by one of the following methods: DMX 512 DALI 0-10V (PW or TD version only)
The fixture is equipped with two DMX and DALI connection blocks (on the PCB RB
- for easy connection to a DMX or DALI chain (In/Out method).
- Set desired position of the LED unit by means of the hanging wire (6). If you need to pull the hanging wire (6) out of the wire lock, you have to press and hold the part (16) of the wire lock.
If you need to align the LED unit, use the three locks on the hanging wires (15). To pull the hanging wire (15) out of the wire lock, you have to press and hold the part (17) of the wire lock.
DMX and DALI address setting and control
The DIP switch on the control PCB (RB3729) allows you to set DMX address and
run a test light.
DIP 10 – if it is switched to ON=test light (the fixture lights at 3200K (for
RGBW and TW version))
DIP 11 – has to be switched to OFF position to receive DMX 512 and DALI,
position ON=0-10V control
Note: If DIP 11=OFF (fixture is controlled by DMX and DALI), the last coming
command switches the fixture to the corresponding operation mode (DMX
operation by a DMX command, DALI operation by a DALI command). E.g. the
fixture stays in a DALI operation and last coming command is a DMX command
which switches the fixture to DMX operation. Next command is a DALI command
and switches the fixture to the DALI operation etc.
If you need the permanent DALI operation, you have to send a DALI command 8 to
the fixture.
DMX control
The DMX start address, is the first channel used to receive instructions from
the DMX controller. The address may be any channel from 1 to 512. DMX address
can be set either by DIP switch or by RDM. DMX address set by RDM overwrites
address set by DIP switch and vice versa. The green LED on PCB signals way of
DMX address setting:
LED lights-DMX address is set by means of the DIP switch.
LED does not light-DMX address is set by means of RDM.
The DIP 11 has to be set to OFF position. Example of DMX addresses:
DALI control
Addressing of the fixture has to be made by means of an external DALI
controller.
If you need to start the permanent DALI control of the fixture (fixture will
not respond to DMX commands), the external DALI controller has to send
activating command (8=ON).
If you need to stop the permanent DALI control of the fixture, the external
DALI controller has to send deactivating command (0=OFF).
10V control
DIP 11 has to be set in ON position. 0-10V operation has priority to DALI and
DMX commands. The option is applicable for the PW and TD version of the
Ambiane MP111 Pendant Remote only.
RDM
This fixture supports RDM operation. RDM (Remote Device Management) is a bi-
directional communication protocol for use in DM X512 control systems, it is
the new open standard for DMX512 device configuration and status monitoring.
RDM allows you to set a DMX address, select DMX mode, readout software version
of the fixture etc. It is also used for fixture software update by means of
the Robe Uploader.
RDM model ID for the Ambiane MP111 Pendant Remote is: 0x0140.
Parameter ID | Discovery command | SET command | GET command |
---|---|---|---|
DISC_UNIQUE_BRANCH | * | ||
DISC_MUTE | * | ||
DISC_UN_MUTE | * | ||
DEVICE_INFO | * | ||
SUPPORTED_PARAMETERS | * | ||
SOFTWARE_VERSION_LABEL | * | ||
DMX_START_ADDRESS | * | * | |
IDENTIFY_DEVICE | * | * | |
DEVICE_MODEL_DESCRIPTION | * | ||
MANUFACTURER_LABEL | * | ||
DEVICE_LABEL | * | * | |
DMX_PERSONALITY | ***** | ***** | |
DMX_PERSONALITY_DESCRIPTION | ***** | ||
SENSOR_VALUE | * | * | |
SENSOR_DEFINITION | * | ||
SLOT_INFO | * | ||
SLOT_DESCRIPTION | * | ||
DEFAULT_SLOT_VALUE | * | ||
PARAMETER_DESCRIPTION | * |
Example of Control panel in RDM manager
Manufacturer PIDs
- DMX hold [00]- last received DMX values are held in case of DMX signal lost.
- DMX hold [01]- option “DMX lost“ is activated and influences behaviour of the fixture at DMX signal lost. Default value is [00].
- DMX lost [00]- the fixture lights on full power (dimmer open) at DMX signal lost.
- DMX lost [01]- the fixture close light output at DMX signal lost.
- Default value is [00].
- Power Switch [00]- the fixture uses primary power.
- Power Switch [01]- the fixture uses secondary power.
- Default value is [00].
DMX protocols
Variant RGBW, version 1.1
Mode 1
Channel
| Mode 2
Channel
| Mode 3
Channel
| Mode 4
Channel
| Mode 5
Channel
| DMX
value
| Function| Type of control
---|---|---|---|---|---|---|---
1| 1| 1| –| 1|
0-255
| Red
Red LEDs saturation control (0–>100%)
|
proportional
–| –| 2| –| –|
0-255
| Red Fine
Red LEDs saturation control (0–>100%)
|
proportional
2| 2| 3| –| 2|
0-255
| Green
Green LEDs saturation control (0-100%)
|
proportional
–| –| 4| –| –|
0-255
| Green Fine
Green LEDs saturation control (0–>100%)
|
proportional
3| 3| 5| –| 3|
0-255
| Blue
Blue LEDs saturation control (0 –>100%)
|
proportional
–| –| 6| –| –|
0-255
| Blue Fine
Blue LEDs saturation control (0–>100%)
|
proportional
4| –| 7| –| 4|
0-255
| White
White LEDs saturation control (0–>100%)
|
proportional
–| –| 8| –| –|
0-255
| White Fine
White LEDs saturation control (0–>100%)
|
proportional
–| –| 9| 1| | | Green correction|
| | | | 0| Uncorrected white| step
| | | | 1-127
128
129-
255
| Minus green –> uncorrected white Uncorrected white (128=default) Uncorrected white –> Plus green| proportional
step
proportional
–| –| 10| 2| | | Colour temperature correction (CTC)|
| | | | 0| No function (0=default)| step
| | | | 1-10| Tungsten dimming 2700 K| step
| | | | 11-20| Tungsten dimming 3200 K| step
| | | | 21-255| Colour temperature changing 2700 K–> 6500 K| proportional
–| –| 11| 3| 5|
0-255
| Dimmer
Light intensity coarse (0–>100%)
|
proportional
–| –| 12| –| 6|
0-255
| Dimmer Fine
Light intensity fine (0–>100%).
|
proportional
Variant TW, version 1.2
Mode 1
Channel
| Mode 2
Channel
| Mode 3
Channel
| Mode 4
Channel
| DMX
value
| Function| Type of
control
---|---|---|---|---|---|---
1| –| 1| –|
0-255
| White colour selection
White from 2700K–>4000K
|
proportional
–| 1| –| 1|
0-255
| Warm White
Warm white LEDs saturation control (0–>100%)
|
proportional
–| 2| –| 2|
0-255
| Cool White
Cool white LEDs saturation control (0–>100%)
|
proportional
2| 3| 2| 3|
0-255
| Dimmer
Light intensity (0–>100%)
|
proportional
–| –| 3| 4|
0-255
| Dimmer Fine
Light intensity fine (min–>max)
|
proportional
Variant TD, PW version 1.1
Mode 1
Channel
| Mode 2
Channel
| DMX
value
| Function| Type of
control
---|---|---|---|---
1| 1|
0-255
| Dimmer
Light intensity coarse (0–>100%)
|
proportional
–| 2|
0-255
| Dimmer Fine
Light intensity (0–>100%)
|
proportional
Technical specifications
- Nominal input voltage: 48V DC
- Input voltage range: 44-50V DC
- Max. power consumption (primary power): 42W
- Max. power consumption (secondary power): 20W
- Max. operating time for secondary power: 3 hours
- Light source: High Power LED module
- Beam angle: 20°, 40°,60°, 80°
- Projected Lumen Maintenance: L90B10 >90.000 hrs, Ta = 25°C / 77°F °F)
- Colour Variants: RGBW (W – 2700K or 4000K), PureWhite, Tunable White, Tungsten Dim
- Colour Temperature of White: PW 2700 K or 4000K, TW 2700 – 4000K, TD 3200K
- CRI: 90+
- Control: DMX, DALI 2 , RDM, 0-10V
- Settings/Addressing: DIP Switch, RDM
- DMX channels (RGBW variant): 4 (Mode 1), 3 (Mode 2), 12 (Mode 3), 3 (Mode 4), 6 (Mode 5)
- DMX channels (TW variant): 2 (Mode 1), 3 (Mode 2), 3 (Mode 3), 4 (Mode 4)
- DMX channels (TD, PW variant): 2 (Mode 1), 2 (Mode 2)
- Power supply (CE): Ambiane Power HP (48V/100W), Ambiane Power Rack
- Power supply (US): Ambiane Power HP (48V/100W), Ambiane Power Rack US
- Operating ambient temp. range: -20 °C / +40 °C (-4 °F / +104 °F)
- Operating Temperature (LED unit): +75 °C @ Ambient +40 °C (167 °F @ Ambient 104 °F)
- Total heat dissipation: 107 BTU/h (calculated)
- Cooling: convection
- Housing: High Pressure Die-Cast Aluminium Body
- Weight (without control unit) :
- Ambiane MP111 Pendant Remote 20° 2.3 kg/ 5.07 lbs
- Ambiane MP111 Pendant Remote 40° 2.3 kg/ 5.07 lbs
- Ambiane MP111 Pendant Remote 60° 2.2 kg/ 4.85 lbs
- Ambiane MP111 Pendant Remote 80° 2.2 kg/ 4.85 lbs
- Mounting Method: Pendant with 1 adjustable hanging wire
- IC rating: Non-IC rated
- Power connection Connectors
- DMX connection: Connectors
- DALI connection: Connectors
- LED unit connection: Connector
- Protection factor (CE): IP20
- Protection factor (US): Dry location only
Dimensions
mm [inch]
- Ambiane MP111 Pendant Remote 20° H = 271 mm [10 5/8 inch]
- Ambiane MP111 Pendant Remote 40° H = 275 mm [10 13/16 inch]
- Ambiane MP111 Pendant Remote 60° H = 257 mm [10 10/18 inch]
- Ambiane MP111 Pendant Remote 80° H = 241 mm [9 1/12 inch]
Control unit
Included items
- 1 x Ambiane MP111 Pendant Remote
- 1 x Control unit
- 1 x Set of cable connectors
- 1 x User manual
Optional accessories
- Ambiane Power HP (MeanWell ELG-100-48-3Y) (P/N 10064073)
- Ambiane Power Rack (P/N 10063951), black colour
- Ambiane Power Rack US (P/N 10063873), black colour
Cleaning and maintenance
Keep the fixture clean, especially light source and the ribbed ribbed heat sink. Maintenance and service operations are only to be carried out by a qualified person. Should you need any spare parts, please use ROBE OEM parts.
Software update
The fixture has to be connected to power during software update.
Software update by means of the Robe Uploader
The ROBE Uploader is a software for automatized software update of Robe and
Anolis fixtures. It can take advantage of RDM support.
The fixtures have to be connected in a daisy-chain (max. 32 fixtures) and via
the Robe Universal Interface/Robe Universal Interface WTX and a USB cable
connected to the control PC with the Robe Uploader running.
The fixtures have to be connected to power. The control PC should be connected
to the Internet.
Ambiane MP111 Pendant Remote
The Robe Uploader software and user manual is available at https://www.robe.cz
/robe-uploader/
If you do the software update by means of the Robe Uploader, switching
fixtures to the update mode (and from the update mode) is made automatically.
Note: The Robe Uploader software cannot be used if fixtures are connected by means of DALI connection.
Disposing of the product
To preserve the environment please dispose or recycle this product at the end
of its life according to the local regulations and codes.
ChangeLog
This section summarizes changes in the user manual.
Version of manual | Date of issue | Description of changes |
---|---|---|
1.1 | 28/11/2023 | Power supply changed to 42W |
1.2 | 16/02/2024 | Notice about Protection class III added to Safety instructins |
February 16, 2024
Copyright © 2024 Robe Lighting – All rights reserved
All Specifications subject to change without notice
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701