COMMSCOPE TC-96368-IPrC Mass Fusion Splice Cassette For CHD Panel User Guide

August 23, 2024
CommScope

COMMSCOPE TC-96368-IPrC Mass Fusion Splice Cassette For CHD Panel

Specifications

  • Product Name : MPO Splice Cassette for Propel Panel
  • Included Materials: Splice Protectors (45 mm Long), Cable Ties (30-40 mm)
  • Tools Required: Marker, Small Side Cutter, Fiber Scissors, Stripper, Tape Measure, Fiber Fusion Splicer and Cleaver, Isopropyl Alcohol

Product Usage Instructions

  • Step 1: Prepare Cable for Single Fiber Splice Cassette Installation
  • Refer to Table 1 for Feeder and Pigtail Lengths. Ensure the Feeder Initial Length, Feeder Cut Length, and Pigtail Cut Length are as recommended. Only one rework per splice is allowed.
  • Step 2: Remove Cassette Cover Using your thumb and finger, disengage the rear tab by lifting and pulling backward to remove the cover.
  • Step 3: Prepare to Place Feeder Fiber in Cassette (a) Remove the spool and splice holder from the cassette. Discard foam blocks. (b) Locate the ends of the pigtail marked with tape. Unspool and extend the fiber beyond the front of the cassette.
  • Step 4: Install Feeder Fiber in Splice Cassette (a) Insert plastic sleeves into mesh sleeve and secure using tape. Insert feeder fiber into the sleeve. (b) Secure feeder fiber using two cable ties. (c) Trim off excess cable tie ends. (d) Push the head downward until it is below the top of the cassette wall.
  • Step 5 : Remove the Splice Spool from the Splice Cassette Extend feeder fibers beyond the base front, then measure and trim the pigtail and feeder to specified cut lengths per Table 1.
  • Step 6 : Install Splice Protectors on All Fibers to be Spliced Use the provided Splice Protectors. Ensure the splice protector length does not exceed 45mm.
  • Step 7 : Preparing to Load Splice Protectors Locate P and F markings on the spool. Load splice protectors ensuring pigtail exits through the side marked with P and feeder exits through the side marked with F.
  • Step 8: Splice Feeder and Pigtail Fibers Strip, clean, and splice fibers following the recommended method. Note the MPO positions indicated on the pigtail labels.
  • Step 9 : Load Splice Protectors into Splice Holder Load the splice protectors into the splice holder.

Prepare cable for single fiber splice cassette installation
Refer to Table 1 for Feeder and Pigtail Lengths. “Feeder Initial Length” is the recommended length of fiber to bring into the cassette. “Feeder Cut Length” and “Pigtail Cut Length” are measured from the front of the cassette and are the recommended cut lengths for the initial splices. A maximum of (1) rework is allowed per splice.

Remove cassette cover
Using thumb and finger, disengage rear tab by lifting and pulling backward to remove the cover.

Prepare to place feeder fiber in casette
(a) Remove spool and splice holder from cassette. Then, remove and discard foam blocks. (b) Locate ends of pigtail marked with tape, then unspool and extend fiber beyond front of cassette.

Install feeder fiber in splice cassette
(a) Insert plastic sleeves into mesh sleeve and secure using tape. Insert feeder fiber into sleeve.(b) Secure feeder fiber using two cable ties. (c) Snip off ends of cable ties close to head. (d) Push the head downward until it is below the top of the cassette wall, and push cable ties towards the back of the cassette.

Remove splice spool from splice cassette
Extend feeder fibers beyond the front of the base, then measure and trim pigtail and feeder to specified cut length per Table 1.

Install splice protectors on all fibers to be spliced
Use provided splice protectors. Splice protector length should be 45mm maximum.

Preparing to load splice protectors
Locate “P” and “F” marking on spool. When loading splice protectors, ensure pigtail is exiting spool through the side with “P” marking and the feeder is existing through the side with “F” marking.

Splice feeder and pigtail fibers
Strip, clean, and splice fibers following recommended method. Note the labels on the pigtail indicating MPO positions.

Load splice protectors into splice holder
(a) Load splice protectors into splice holder (b) Utilizing the spool fiber fingers, route pigtail fibers counterclockwise until feeder and pigtail fibers converge.

Wrap ribbon into spool
(a) Position spool to prepare for routing. (b) Route pigtail and feeder fibers counterclockwise starting along the outer walls and working towards the center of the cassette. (c) Line up the pegs on the cassette base with the mounting holes on the spool to finish routing. (d) Insert spool into the base and ensure all fibers are under retaining fingers.

Apply Cover

  • (a) Line the tabs on the cover with the slot near the front of the cassette base.
  • (b) Lay the cover flat on the base and ensure all the tabs on the side of the cover and bases are lined up. With one hand holding the cassette base, push the cover forward with the other hand to engage the tabs. Double-check check the rear tab is also engaged to prevent the cover from sliding off.

scanner

© 2023, CommScope, Inc. All Rights Reserved.
Product Patents: http://www.cs-pat.com

FAQ

  • Q: What should I do if I encounter difficulties during the installation process?
    • A: If you face any challenges during installation, refer to the product manual for detailed instructions. If issues persist, contact customer support for assistance.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CommScope User Manuals

Related Manuals