COMMSCOPE P040-0097 Top Mounting Kits Instructions

June 1, 2024
CommScope

COMMSCOPE logo P040-0097 Revision A,
October 2023
Mounting Kits For
Small cell Antennas

P040-0097 Top Mounting Kits

MC-MNT-SIDE-370: Mounting systems for cylindrical pipe installations (50-250mm pipe diameter)
Suitable for small cell cylindrical antennas with a weight less than 20KG and dimensions less than diameterheight: 370610mm.

Installation Preparations

All fasteners must be tightended to the defined torque value after onsite installation, see mounting kit installation diagrams on following pages for correct torque recommendations.
Figure 1 Installation tools lists
Installation tools listCOMMSCOPE P040 0097 Top Mounting Kits -
PreparationsTable 1 Installation tools lists

Tool Size Torque Range
Torque wrench 10mm 14Nm (11ft.lbs)
Socket 10mm 14Nm (11ft.lbs)
Torque wrench 19mm 58Nm (43ft.lbs)
Socket 19mm 58Nm (43ft.lbs)
Torque wrench 36mm 100Nm (74ft.lbs)
Socket 36mm 100Nm (74ft.lbs)
ITEM NO. DESCRIPTION QTY
--- --- ---
1 MOUNTING BRACKET,W/GASKET 1
2 POLE CLAMP,MAIN BODY 1
3 POLE CLAMP,MAIN BODY 1
4 SCR,HCS,HEX,M24X80,STL,GALV 1
5 SCR,HCS,HEX,M6X40,SST,PASS 2
6 BOLT,CARRIAGE,M12X270,STL,GALV 2
7 BOLT,CARRIAGE,M12X45,STL,GALV 4
8 WSHR,FLT,M24,25X44X4,STL,GALV 1
9 WSHR,FLAT,M6,6.4x12x1.6,SST,PASS 4
10 WSHR,FLAT,M12,13X40X6,STL,GALV 2
11 WSHR,FLT,M12,13X24X2.5,STL,GALV 4
12 NUT,HEX,M24,STL,GALV 2
13 NUT,HEX,M6-1,SST,PASS 4
14 NUT,HEX,M12,STL,GALV 12
15 WSHR,FLAT,M24,25X100X5 STL,GALV 1

Part Lists

COMMSCOPE P040 0097 Top Mounting Kits - Part ListsCOMMSCOPE P040 0097 Top Mounting Kits - Part Lists
1COMMSCOPE P040 0097 Top Mounting Kits - PIPE
DIAMETER GENERAL INFORMATION
After removing the antenna from its shipping container carefully inspect it to ensure there is no shipping damage. If the antenna is to be hoisted into position, ensure the lifting eye bolt is correctly installed. Ensure the antenna is securely held during hoisting to avoid rotation on the lifting eye bolt.
INSTALLATION INSTRUCTIONS
Refer to Figures 2 and 3 for mounting and arrow direction. It is recommended that the mounting holes be marked and made ready in the mounting surface prior to installing the antenna.
The arrow of each antenna is shown on brakcet one side. The direction of each antenna must be considered prior to mounting to ensure desired performance.
COMMSCOPE P040 0097 Top Mounting Kits - PIPE DIAMETER
1COMMSCOPE P040 0097 Top Mounting Kits -
PIPE DIAMETER 2COMMSCOPE P040 0097 Top Mounting Kits - PIPE DIAMETER
3COMMSCOPE P040 0097 Top Mounting Kits -
PIPE DIAMETER 4MC-MNT-SIDE-370
SAFETY NOTICE
The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment.
CommScope disclaims any liability or responsibility for the results of improper or unsafe installation practices.
It is recommended that transmit power be turned off when the field installation is performed. Follow all applicable safety precautions as shown on this page.
Do not install near power lines.
Power lines, telephone lines, and guy wires look the same.
Assume any wire or line can electrocute you.
Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use metal ladder.
COMMSCOPE P040 0097 Top Mounting Kits - SAFETY NOTICE
2Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves.
Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

www.commscope.com
© 2023 CommScope, Inc. All rights reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CommScope User Manuals

Related Manuals