S G TORRICE TEM4A0B31M31SB Convertible Air Handler
Product Information
- Product Name: Air Handler Model A TEM4A0B31M31SB
- Manufacturer: Not specified
- Model Number: TEM4A0B31-SUB-1D-EN
- Dimensions: Crated (In.) HxWxD 48-1/4 x 22-1/2 x 25-1/2, Uncrated 46-3/4 x 18-1/2 x 21-1/8
- Weight: Shipping (Lbs.) / Net (Lbs.) 145/138
- Rated Voltage/Phase/Hertz: 208-230/1/60
- Refrigerant: R-410A
- Heater Model Numbers: BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG, BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG, BAYHTR1517BRK, BAYHTR3517LUG, BAYHTR3510LUG, BAYHTR1523, BAYHTR1525
Product Usage Instructions
To install and use the Air Handler Model A TEM4A0B31M31SB:
- Ensure that the unit is approved for installation clearances to combustible material as stated on the unit rating nameplate.
- Refer to the Split System Outdoor Unit Product Data Guides for performance data and approved combinations of Air Handlers and Heaters.
- Install the air handler according to the outline drawing provided in the user manual.
- Connect the refrigerant line using a 3/8-inch coupling or connection size for the liquid line and a 3/4-inch coupling or connection size for the gas line.
- Connect the ducts to the indoor fan, which is a centrifugal type with a diameter width of 11 x 8 inches and one direct drive at five speeds. Refer to the fan performance table for more information.
- Install the heater racks and connect them to the appropriate heater model number as listed in the user manual.
- Turn on the air handler and adjust the airflow speed according to your needs using the minimum heat speed tap. Refer to the heater pressure drop table for more information.
Outline Drawing
PRODUCT DIMENSIONS
Air Handler Model| A| B| C| D| E| F| H| Flow Control| Gas Line Braze
TEM4A0B31M31SB| 46.77| 18.50| 16.50| 16.75| 4.68| 7.33| 20.09| TXV| 3/4
All dimensions are in inches
Product Specifications
MODEL | TEM4A0B31M31SB |
---|---|
RATED VOLTS/PH/HZ | 208-230/1/60 |
RATINGS (a) | See O.D. Specifications |
INDOOR COIL — Type | Plate Fin |
Rows — F.P.I. | 4 – 14 |
Face Area (sq. ft.) | 3.44 |
Tube Size (in.) | 3/8 |
Refrigerant Control | TXV |
Drain Conn. Size (in.)(b) | 3/4 NPT |
DUCT CONNECTIONS | See Outline Drawing |
INDOOR FAN — Type | Centrifugal |
Diameter-Width (In.) | 11 X 8 |
No. Used | 1 |
Drive – No. Speeds | Direct – 5 |
CFM vs. in. w.g. | See Fan Performance Table |
No. Motors — H.P. | 1 – 1/3 |
Motor Speed R.P.M. | 1050 |
Volts/Ph/Hz | 208-230/1/60 |
F.L. Amps | 2.8 |
FILTER | |
Filter Furnished? (c) | No |
REFRIGERANT | R-410A |
Ref. Line Connections | Brazed |
Coupling or Conn. Size — in. Gas | 3/4 |
Coupling or Conn. Size — in. Liq. | **** |
3/8
---|---
DIMENSIONS| H x W x D
Crated (In.)| 48-1/4 x 22-1/2 x 25-1/2
Uncrated| 46-3/4 x 18-1/2 x 21-1/8
WEIGHT|
Shipping (Lbs.) / Net (Lbs.)| 145/138
- These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
- 3/4” Male Plastic Pipe (Ref: ASTM 1785–76)
- Remote filter required.
Minimum Airflow CFM
TEM4A0B31M31SB
Heater| Minimum Heat Speed Tap
| With Heat Pump| Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG| ****
Low
| ****
Low
BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG| ****
Med-High
| ****
Med-Low
BAYHTR1517BRK, BAYHTR3517LUG, BAYHTR3510LUG| ****
High
| ****
Med
Heater Pressure Drop Table TEM Air Handler Models
Airflow CFM
| Number of Racks| | Heater Racks
---|---|---|---
1| 2| 3| 4| Heater Model| No. of Racks
Air Pressure Drop — Inches W.G.| BAYHTR1504| 1
1800| 0.02| 0.04| 0.06| 0.14| BAYHTR1505| 1
1700| 0.02| 0.04| 0.06| 0.14| BAYHTR1508| 2
1600| 0.02| 0.04| 0.06| 0.13| BAYHTR1510| 2
1500| 0.02| 0.04| 0.06| 0.12| BAYHTR3510| 3
1400| 0.02| 0.04| 0.06| 0.12| BAYHTR1517| 3
1300| 0.02| 0.04| 0.05| 0.11| BAYHTR3517| 3
1200| 0.01| 0.04| 0.05| 0.10| BAYHTR1523| 4
1100| 0.01| 0.03| 0.05| 0.09| BAYHTR1525| 4
1000| 0.01| 0.03| 0.04| 0.09| |
900| 0.01| 0.03| 0.04| 0.08| |
800| 0.01| 0.03| | | |
700| 0.01| 0.02| | | |
600| 0.01| 0.02| | | |
Performance and Electrical Data
- See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters.
- Heater model numbers may have additional suffix digits.
Table 1. Air Flow Performance
TEM4A0B31M31SB (a)
EXTERNAL STATIC
(in w.g)
| AIRFLOW
Speed Taps: 208 – 230 VOLTS
| High| Med-High| Med †| Med-Low| Low
0.1| 1192| 1127| 1070| 995| 940
0.2| 1148| 1079| 1021| 943| 885
0.3| 1103| 1031| 971| 890| 828
0.4| 1057| 980| 919| 834| 767
0.5| 1009| 929| 865| 775| 702
0.6| 961| 875| 810| 714| 635
0.7| 911| 820| 753| 651| 564
1. Values are with wet coil, no filter, and no heaters
2. CFM Correction for dry coil = Add 3%
3. † = Factory Setting
4. Low = Tap 1, Med-Low = Tap 2, Med = Tap 3, Med-High= Tap 4, High = Tap 5
- For the TEM4A0B31M31SB in downflow applications, airflow must not exceed 1200 cfm due to condensate blow off.
Table 2. Electrical Data
TEM4A0B31M31SB
Heater Model No.
| No. of Circuits/ Phases| 240 Volt| 208 Volt
Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload
Protection| Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity|
Maximum Overload Protection
kW| BTUH| kW| BTUH
No Heater| | | | 2.8 | 4| 15| | | 2.8 | 4| 15
BAYHTR1504BRK BAYHTR1504LUG| 1/1| 3.8| 13100| 16.0| 24| 25| 2.9| 9800| 13.8|
21| 25
BAYHTR1505BRK BAYHTR1505LUG| 1/1| 4.8| 16400| 20.0| 29| 30| 3.6| 12300| 17.3|
25| 25
BAYHTR1508BRK BAYHTR1508LUG| 1/1| 7.7| 26200| 32.0| 44| 45| 5.8| 19700| 27.7|
38| 40
BAYHTR1510BRK BAYHTR1510LUG| 1/1| 9.6| 32800| 40.0| 54| 60| 7.2| 24600| 34.6|
47| 50
BAYHTR1517BRK-
Circuit 1 (a)
| ****
2/1
| 9.6| 32800| 40.0| 54| 60| 7.2| 24600| 34.6| 47| 50
BAYHTR1517BRK-
Circuit 2
| 4.8| 16400| 20.0| 25| 25| 3.6| 12300| 17.3| 22| 25
BAYHTR3510LUG| 1/3| 9.6| 32800| 23.1| 32| 35| 7.2| 24600| 20.0| 28| 30
BAYHTR3517LUG| 1/3| 14.4| 49100| 34.6| 46| 50| 10.8| 36900| 30.0| 41| 45
BAYHTR1517BRK
with single circuit power source kit
BAYSPEKT201A
| ****
1/1
| ****
14.4
| ****
49100
| ****
60.0
| ****
83
| ****
90
| ****
10.8
| ****
36900
| ****
51.9
| ****
73
| ****
80
-
= Motor Amps
- MCA and MOP for circuit 1 contain the motor amps.
Features and Benefits
- Painted metal cabinet with captured foil face insulation
- 2% or less air leakage
- R-4.2 Insulating Value
- Multi-Position UP/Down Flow, Horizontal Left /Right
- ALL Aluminum Coil
- Electric Heaters with polarized plug connections (sold as accessories)
- R-410A Thermal Expansion Valve
- ECM Motor ((33..55 –– 55 TToonn MMooddeellss ))
- Low Voltage Pigtail Connections
- Draw Through Design
- Horizontal Drain pan
- Fused 24V Power
- 33-year warranty
- 1100–year warranty registered
- Optional extended warranty available
Important: Condensate management kit is required for all 5-ton air handler models installed in downflow applications. About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
- TEM4A0B31-SUB-1D-EN 16 Sep 2022 Supersedes TEM4A0B31-SUB-1C-EN (March 2022)