ADS ECHO Level Monitoring System Installation Guide
- June 12, 2024
- aDS
Table of Contents
IMPORTANT – Read entire document and watch all associated videos before installing the ECHO™!
ECHO QUICK INSTALLATION GUIDE
Complete STEP 1: INITIAL SETUP from the document “ECHO Start-Up Guide”
before installing the ADS® ECHO in the field.
The ADS ECHO is a level monitoring system for use in overflow prevention. It measures flow depth in the manhole with echo ranging technology. It reliably reads up to 20 feet (6.1 m) from the bottom of the reflector. Its press sure sensor measures depths above the ECHO up to and including the manhole rim.
CHECKLIST! Required installation supplies:
ECHO monitor Blue magnet Antenna **** Mounting bar
J-hook Rubber splicing tape Carpenter’s rule Grade pole
- Pressure Sensor
- Ultrasonic Sensor
- Manhole Depth
Watch ADS ECHO Start-up Videos
“How to install the ADS ECHO Level Monitor”
“How to install an antenna for use with ADS Monitors”
“How to configure and activate an ADS ECHO with Q start™XML“
Scan the QR code to access our instructional videos or enter
https://www.adsenv.com/echo
Follow the steps below to complete the ECHO installation.
1. Measure the Manhole Depth
1.1 Measure Distance from the Bottom of the Invert …
1.2 …to the Manhole Rim, and Record the Manhole Depth Value
2. Install the Mounting Bar
IMPORTANT: Install mounting bar at least 14 inches (355 mm) below the
manhole rim to prevent the manhole lid from dislodging the bar and monitor.
2.1 Pass Mounting Bar Tether Behind Top Rung
2.2 Use J-Hook to Pull Tether up from Top Rung
2.3 Pass Untethered End Through Large Loop
2.4 Pull Tether Tight, Cinching to the Top Rung
2.5 Ensure Bar Installation Gives Clear Line of Sight to the Invert
2.6 Expand, Level, and Confirm Secure Positioning of Bar
3. Install the ECHO Monitor
3.1 Attach
Antenna to ECHO and Wrap Connection with Rubber Splicing Tape
3.2 Lower and Place ECHO on Mounting Bar
3.3 Level the ECHO and Tighten the Mounting Clamp
3.4 ECHO
Fully Installed
3.5 Ensure Installation of the ECHO Places the Effective Section of the
Sensor Directly Over the Channel
3.6 Measure Distance from the Rim of the Manhole to the Face of the
Sensor, Record the Physical Offset Value
4. Install the Antenna
The ADS ECHO 9000-ECHO-4VZ and 9000-ECHO-4WW communications often provide enough wireless signal strength to install the antenna in the manhole with the monitor. The following instructions are applicable when the monitor wireless signal strength is between -50 and -85 dB while the antenna is inside the manhole with the lid closed. Install the antenna in the manhole as described below. If the signal strength is not sufficient, remove the antenna and install it outside the manhole. Watch the “ How to Install an Antenna for use with ADS Monitors ” instructional video using the QR code on the front page to assist in the installation or refer to the ADS ECHO Operations and Maintenance Manual , Chapter 3 for additional detail.
Option 1. Antenna Cabled Tied to Bar, Logo Facing Up
Option 2. Antenna on top of ECHO , Logo Facing Up
Use a cable tie to secure the antenna to the Mounting Bar (Option 1) or place it between the Mounting Bar and the top of the ECHO (Option 2). Position the antenna as flat and parallel to the manhole lid as possible with the ADS logo facing up. Loop the antenna cable around the ECHO handle. The antenna should be within 14 to 18″ (350 and 460 mm) of the manhole lid for optimal signal strength.
Download Documents fromhttps://www.adsenv.com/ads-product-manuals/ to help install the ECHO.
“ECHO Quick Installation Guide” to share this document with co-workers.
“ADS ECHO Qstart XML Quick Reference Guide” to configure and activate the
ECHO.
“ADS ECHO Installation, Operation, and Maintenance Manual” for detailed
information regarding installation, Intrinsically Safe (IS) certifications and
maintenance restrictions.
IMPORTANT! Manhole and sewer system work involves confined space entry and is inherently dangerous. Installers and technicians should comply with all federal, state, and municipal regulations concerning confined space entry.
For Further Assistance Call
1-877-237-9585
or Email adssupportcenter@idexcorp.com
© 2023 ADS LLC. All Rights Reserved.
www.adsenv.com/echo
QR 775032 A2