Ecoer EBAC02DFA Downflow Kit Installation Guide
- August 21, 2024
- ecoer
Table of Contents
Ecoer EBAC02DFA Downflow Kit
Product Information
Specifications
- Product Name: Downflow Kit
- Material: Metal
- Usage: Configuring airflow direction downward or horizontally left
Product Usage Instructions
Installation Guide
- Disconnect all power to the unit before installation.
- Prepare two Downflow kits.
- Remove the coil and insert the Downflow Kit between the coil and the drain pan.
- Apply sealant to the four corners of the drain pan and coil.
- Reassemble the coil back into the unit.
The Downflow Kit can also be used for horizontal left airflow direction:
- Install a Downflow Kit on the top.
- Apply sealant to the two corners of the drain pan and coil on the side where the Downflow Kit is installed.
FAQ
-
Q: Can the Downflow Kit be used for both downward and horizontal left airflow?
A: Yes, the Downflow Kit can be used to configure airflow in both downward and horizontal left directions. -
Q: Is it necessary to apply sealant during installation?
A: Yes, sealant should be applied to ensure proper sealing of the components.
WARNING
Disconnect all power to unit before installing or servicing. More than one disconnecting switch may be required to de-energize the equipment. Hazardous voltage can cause severe personal injury or death.
ALL phases of this installation must comply with NATIONAL, STATE, AND LOCAL CODES
IMPORTANT
This Document is customer property and is to remain with this unit. Please
return to the service information pack upon completion of work
DESCRIPTION
The Downflow kit is a metal component installed between the coil and the water
tray. By installing the Downflow kit, the airflow direction of the unit can be
configured to be downward or horizontally left.
The Downflow kit is depicted below
Down Air Flow Diagram
Horizontal Left Air Flow Diagram
Downflow Kit
PARTS LIST FOR KITS
Item/Qty.
- Sheet metal bar 2
- Installation Guide 1
Installation
The steps for installing the kit are as follows
- Step 1: Prepare two Downflow kits. Remove the coil and insert the Downflow Kit between the coil and the drain pan.
- Step 2: Apply sealant to the four corners of the drain pan and coil
- Step 3: Reassemble the coil back into the unit.
The Downflow Kit can also be used to achieve the airflow direction in a horizontal left application. Simply install a Downflow Kit on the top, and apply sealant to the two corners of the drain pan and coil on the side where the Downflow Kit is installed.
©2024 ECOER INC.
43671 Trade Center Place, Suite 100Dulles, VA 20166 USA
Tel : 703-348-2538
www.ecoer.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>