Ecoer EBAC02DFA Downflow Kit Installation Guide

August 21, 2024
ecoer

Ecoer EBAC02DFA Downflow Kit

Product Information

Specifications

  • Product Name: Downflow Kit
  • Material: Metal
  • Usage: Configuring airflow direction downward or horizontally left

Product Usage Instructions

Installation Guide

  1. Disconnect all power to the unit before installation.
  2. Prepare two Downflow kits.
  3. Remove the coil and insert the Downflow Kit between the coil and the drain pan.
  4. Apply sealant to the four corners of the drain pan and coil.
  5. Reassemble the coil back into the unit.

The Downflow Kit can also be used for horizontal left airflow direction:

  1. Install a Downflow Kit on the top.
  2. Apply sealant to the two corners of the drain pan and coil on the side where the Downflow Kit is installed.

FAQ

  • Q: Can the Downflow Kit be used for both downward and horizontal left airflow?
    A: Yes, the Downflow Kit can be used to configure airflow in both downward and horizontal left directions.

  • Q: Is it necessary to apply sealant during installation?
    A: Yes, sealant should be applied to ensure proper sealing of the components.

WARNING

Disconnect all power to unit before installing or servicing. More than one disconnecting switch may be required to de-energize the equipment. Hazardous voltage can cause severe personal injury or death.

ALL phases of this installation must comply with NATIONAL, STATE, AND LOCAL CODES

IMPORTANT
This Document is customer property and is to remain with this unit. Please return to the service information pack upon completion of work

DESCRIPTION

The Downflow kit is a metal component installed between the coil and the water tray. By installing the Downflow kit, the airflow direction of the unit can be configured to be downward or horizontally left.
The Downflow kit is depicted below

Down Air Flow Diagram

Horizontal Left Air Flow Diagram

Downflow Kit

PARTS LIST FOR KITS

Item/Qty.

  • Sheet metal bar 2
  • Installation Guide 1

Installation

The steps for installing the kit are as follows

  • Step 1: Prepare two Downflow kits. Remove the coil and insert the Downflow Kit between the coil and the drain pan.
  • Step 2: Apply sealant to the four corners of the drain pan and coil
  • Step 3: Reassemble the coil back into the unit.
    The Downflow Kit can also be used to achieve the airflow direction in a horizontal left application. Simply install a Downflow Kit on the top, and apply sealant to the two corners of the drain pan and coil on the side where the Downflow Kit is installed.

©2024 ECOER INC.
43671 Trade Center Place, Suite 100Dulles, VA 20166 USA
Tel : 703-348-2538
www.ecoer.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals