ecoer Morley Associates Downflow Kit Installation Guide

August 20, 2024
ecoer

ecoer Morley Associates Downflow Kit

Product Specifications:

  • Product Name: Downflow Kit
  • Material: Metal
  • Application: Configuring airflow direction downward or horizontally left
  • Components: Sheet metal bar x 2, Installation Guide x 1

Product Usage Instructions

Installation Guide:

AIRFLOW WARNING: Disconnect all power to the unit before installing or servicing to avoid hazardous voltage that can cause severe personal injury or death.

  • All phases of this installation must comply with NATIONAL, STATE, AND LOCAL CODES.
  • Refer to the user manual and information pack upon completion of work.

Downflow Kit Installation Steps:

  • Step 1: Preparation
    Prepare two Downflow kits. Remove the coil and insert the Downflow Kit between the coil and the drain pan.

  • Step 2: Apply Sealant
    Apply sealant to the four corners of the drain pan and coil. Squeeze sealant into the inner part of the bulge in the drain pan.

  • Step 3: Reassembly
    Reassemble the coil back into the unit.

Horizontal Left Air Flow Configuration:
The Downflow Kit can also be used to achieve airflow direction in a horizontal left application. Install a Downflow Kit on the top and apply sealant to the two corners of the drain pan and coil on the side where the Downflow Kit is installed.

Frequently Asked Questions (FAQ):

  • Q: Can the Downflow Kit be used for upward airflow configuration?
    A: No, the Downflow Kit is specifically designed for downward or horizontal left airflow configurations.

  • Q: Is additional sealant required for reassembling the coil?
    A: Yes, sealant should be applied to the four corners of the drain pan and coil during reassembly.

WARNING

Disconnect all power to unit before installing or servicing. More than one disconnecting switch may be required to de-energize the equipment. Hazardous voltage can cause server personal injury or death.

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.

DESCRIPTION

The Downflow kit is a metal component installed between the coil and the water tray. By installing the Downflow kit, the airflow direction of the unit can be configured to be downward or horizontal left.
The Downflow kit is depicted below.

PARTS LIST FOR KITS

Item/Qty.

  • Sheet metal bar 2
  • Installation Guide 1

Down Air Flow Diagram

Horizontal Left Air Flow Diagram

Downflow Kit

Downflow Kit Installation

The steps for installing the kit are as follows

  • Step 1: Prepare two Downflow kits. Remove the coil and insert the Downflow Kit between the coil and the drain pan
  • Step 2: Apply sealant to the four corners of the drain pan and coil.
  • Step 3: Reassemble the coil back into the unit.

The Downflow Kit can also be used to achieve the airflow direction in a horizontal left application. Simply install a Downflow Kit on the top, and apply sealant to the two corners of the drain pan and coil on the side where the Downflow Kit is installed.