GRANDSTREAM GCC601X UC/Networking Convergence User Manual

August 17, 2024
GRANDSTREAM

GRANDSTREAM GCC601X UC/Networking Convergence

Technical Specifications
GCC6010 Technical Specifications

Network Ports 2 x 2.5 Gigabit SFP ports and 5 x Gigabit Ethernet ports
Auxiliary Ports 1xMicro-SD, 1xUSB 3.0, 1xReset
Memory 2GB RAM, 32GB eMMC Flash
External Storage N/A
Router IPsec VPN Throughput 2.5Gbps
NAT Sessions 160K
IDS/IPS 900Mbps
PBX Up to 100 users/25 concurrent calls (default 12/4)
Mounting Desktop/Wall-mounting Metal

GCC6010W Technical Specifications

Wi-Fi Standards IEEE 802.11 a/b/g/n/ac/ax
Antennas 3 individual internal antennas (2 x dual band + 1 x Single band

5G)

Product Usage Instructions

Setup and Installation

  1. Connect the appropriate network cables to the designated ports on the device.
  2. If wall-mounting, use the provided mounting material to securely attach the device.

Frequently Asked Questions (FAQ)
Q: How do I reset the device to factory settings?
A: To reset the device, locate the reset button on the device and press it for at least 10 seconds until the LEDs indicate a reset process. Grandstream Networks, Inc.
GCC601X
User Manual
GCC601X – User Manual GCC601X(W) series are defined as mid-range all- in-one convergence devices. Integrates VPN Router, NGFW, Switch or Wi-Fi AP, and IP PBX, covering the collaborative office capabilities of data communication and UC audio and video service. Featuring GbE RJ-45 and SFP ports, it enables high-speed multi-WAN port connectivity for enterprises. This series is convenient and fast to deploy and manage through the local simple Web UI, GDMS, mobile APP, or console. Support unified management and centralized control of Grandstream terminal devices including APs, Switches, and UC endpoints. It is also a security firewall that provides excellent performance and defenses against the most advanced network attacks while achieving unified management and consistent security in complex hybrid environments. Ideal for small and medium enterprises, campuses, government, hotels, remote offices/SOHO, etc. The GCC601x(W) combines the following modules:

  • UHome
  • Networking
  • Firewall
  • Network Nodes
  • PBX
  • UC Endpoints

PRODUCT OVERVIEW

Technical Specifications
The following tables resume all the technical specifications including the hardware and the software specifications.

GCC6010 Technical Specifications


Network Ports

| 2 x 2.5 Gigabit SFP ports and 5 x Gigabit Ethernet ports

*All ports are WAN/LAN configurable, max 3 x WAN

---|---
Auxiliary Ports| 1xMicro-SD, 1xUSB 3.0, 1xReset
Memory| 2GB RAM, 32GB eMMC Flash
External Storage| N/A
Router| 2.5Gbps
IPsec VPN Throughput| 1Gbps
NAT Sessions| 160K
IDS/IPS| 900Mbps
PBX| Up to 100 users/25 concurrent calls (default 12/4)
Mounting| Desktop/Wall-mounting
Material| Metal
LEDs| 7 x single LEDs and 1 x RGB LED for device tracking and status indication
---|---
Connection Type| DHCP, Static IP, PPPoE, PPTP, L2TP


Network Protocols

| IPv4, IPv6, IEEE802.1Q,IEEE 802.1p, IEEE802.1x, IEEE802.3, IEEE 802.3u, IEEE 802.3x,IEEE802.3ab
QoS| VLAN, TOS

Support multiple traffic classes, filter by port, IP address, DSCP, and policing App QoS: Application/protocol monitoring and traffic statistics

VoIP Prioritization

Firewall| DDNS, Port Forwarding, DMZ, UPnP, DoS & Spoofing defense, traffic rules, NAT, ALG DPI, Anti-Virus, IPS/IDS, SSL deep inspection

Content Control: DNS Filtering, Web url/class/content filtering, Application identification and control

VPN| • IPsec VPN Client-to-Site / Si

  • t-to-Site / Site-to-Site
  • IPSec Encryption: 3DES, AES
  • IPSec Authentication: MD5, SHA-1, SHA2-256
  • IPSec Key Exchange: Main/Aggressive Mode, Pre-shared Key, DH Groups 1/2/5/14
  • IPSec Protocols: ESP
  • IPSec NAT Traversal
  • PPTP VPN Server / Client
  • PPTP Encrpytion: MPPE 40-bit, 128-bit
  • PPTP/L2TP Authentication: MS-CHAPv1/2
  • L2TP Client-to-Site
  • OpenVPN® Server / Client
  • OpenVPN® Encryption: AES, DES
  • OpenVPN® Authentication: MD5, SHA-1, SHA2-256, SHA2-384, SHA2-512
  • OpenVPN® Certificate: RSA
  • WireGuard®

Network Management| GDMS, Local Web GUI, CLI (Console, Telnet) and SNMP (v1/ v2c/v3)
Max AP/Clients| Up to 150 GWN APs; Up to 500 Clients




Power and Green Energy Efficiency

| Universal power adaptor included: Input 100-240VAC 50-60Hz Output: 48VDC 1A (48W);

4 x PoE out ports IEEE802.3af/at

Max. PoE Wattage : 36W



Environmental

| Operation: 0°C to 45°C Storage: -30°C to 60°C

Humidity: 5% to 95% Non-condensing



Physical

| Unit Dimension: 191x 101 x 29mm

Unit Weight: 520g

Entire Package Dimension: 300 x 130 x 53 mm

Entire Package Weight: 835g


Package Content

| GCC6010/GCC6011, Universal Power Supply, Rack mount kit (Only GCC6011), Quick Installation Guide
Compliance| FCC, CE, RCM, IC
Wi-Fi Standards| IEEE 802.11 a/b/g/n/ac/ax
---|---



Antennas

| 3 individual internal antennas ( 2 x dual band + 1 x Single band 5G)

2.4GHz: maximum gain 4.5dBi 5 GHz: maximum gain 5dBi

Wi-Fi Data Rates| 5G:

IEEE 802.11ax: 7.3 Mbps to 3603 Mbps IEEE 802.11ac: 6.5 Mbps to 2600 Mbps IEEE 802.11n: 6.5 Mbps to 450 Mbps

IEEE 802.11a: 6, 9, 12, 18, 24, 36, 48, 54 Mbps

2.4G:

IEEE 802.11ax: 7.3 Mbps to 573.5 Mbps IEEE 802.11n: 6.5 Mbps to 300 Mbps IEEE 802.11b: 1, 2, 5.5, 11 Mbps

IEEE 802.11g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps

*Actual throughput may vary depending on many factors including environmental conditions, distance between devices, radio interference in the operating environment and mix of devices in the network



Frequency Bands

| 2.4GHz radio: 2400 – 2483.5 MHz

(2412-2472MHz are channel central frequency range; 2400-2483.5MHz is Frequency band) 5GHz radio: 5150 – 5895 MHz

*Not all frequency bands can be used in all regions


Channel Bandwidth

| 2.4G: 20 and 40 MHz

5G: 20, 40, 80, 160 MHz


Wi-Fi and System Security

| WPA/WPA2-PSK, WPA/WPA2 Enterprise (TKIP/AES); WPA3, anti-hacking secure boot and critical data/control lockdown via digital signatures, unique security certificate and random default password per device
MU- MIMO| 2×2 2G/3×3 5G
Maximum TX Power| 5G: 25.5dBm

2.4G: 24dBm

*Maximum power varies by country, frequency band and MCS rate

Receiver Sensitivity| 2.4G

802.11b: -97dBm@1Mbps, -89dBm@11Mbps; 802.11g: -93dBm @6Mbps, -75dBm@54Mbps;

802.11n 20MHz: -73dBm @MCS7; 802.11n 40MHz: -70dBm @MCS7;

802.11ax 20MHz: -64dBm @ MCS11; 802.11ax 40MHz: -63dBm @MCS11

5G

802.11a: -93dBm @6Mbps, -75dBm @54Mbps;

802.11n: 20MHz: -73dBm @MCS7; 802.11n 40MHz: -70dBm @MCS7

802.11ac 20MHz: -70dBm@MCS8; 802.11ac: HT40:- 66dBm @MCS9; 802.11ac 80MHz: -62dBm @MCS9;

802.11ax 20MHz: -64dBm @ MCS11; 802.11ax 40MHz: -61dBm @MCS11;802.11ax 80MHz:

-58dBm @MCS11

Network Ports| 5 x Gigabit Ethernet ports
*All ports are WAN/LAN configurable, max 3 x WAN
Auxiliary Ports| 1xMicro-SD, 1xUSB 3.0, 1xReset
Memory| 2GB RAM, 32GB eMMC Flash
---|---
External Storage| N/A
Router| 3Gbps
IPsec VPN Throughput| 1Gbps
NAT Sessions| 160K
IDS/IPS| 900Mbps
PBX| Up to 100 users/25 concurrent calls (default 10/4)
Mounting| Desktop
Material| Plastic Mini-Tower
LEDs| 9 x LEDs for device tracking and status indication
Connection Type| DHCP, Static IP, PPPoE, PPTP, L2TP


Network Protocols

| IPv4, IPv6, IEEE802.1Q,IEEE 802.1p, IEEE802.1x, IEEE802.3, IEEE 802.3u, IEEE 802.3x,IEEE802.3ab



QoS

| VLAN, TOS

Support multiple traffic classes, filter by port, IP address, DSCP, and policing App QoS: Application/protocol monitoring and traffic statistics

VoIP Prioritization

Firewall| DDNS, Port Forwarding, DMZ, UPnP, DoS & Spoofing defense, traffic rules, NAT, ALG DPI, Anti-Virus, IPS/IDS, SSL deep inspection

Content Control: DNS Filtering, Web url/class/content filtering, Application identification and

control

VPN|

  • IPsec VPN Client-to-Site / Site-to-Site
  • IPSec Encryption: 3DES, AES
  • IPSec Authentication: MD5, SHA-1, SHA2-256
  • IPSec Key Exchange: Main/Aggressive Mode, Pre-shared Key, DH Groups 1/2/5/14
  • IPSec Protocols: ESP
  • IPSec NAT Traversal
  • PPTP VPN Server / Client
  • PPTP Encrpytion: MPPE 40-bit, 128-bit
  • PPTP/L2TP Authentication: MS-CHAPv1/2
  • L2TP Client-to-Site
  • OpenVPN® Server / Client
  • OpenVPN® Encryption: AES, DES
  • OpenVPN® Authentication: MD5, SHA-1, SHA2-256, SHA2-384, SHA2-512
  • OpenVPN® Certificate: RSA
  • WireGuard®

Network Management| GDMS, Local Web GUI, CLI (Console, Telnet) and SNMP (v1/v2c/v3)
Max AP/Clients| Up to 150 GWN APs; Up to 500 Clients
Power and Green Energy Efficiency| Universal power adaptor included: Input 100-240VAC 50-60Hz

Output: 48VDC 1A (48W)

| PoE: N/A
---|---


**Environmental**

| Operation: 0°C to 45°C Storage: -30°C to 60°C

Humidity: 5% to 95% Non-condensing

Physical| Unit Dimension: 95 x 95 x 193 mm

Unit Weight: 565g

Entire Package Dimension: 186 x 127 x 105 mm

Entire Package Weight: 920g

Package Content| GCC6010W, Universal Power Supply, Quick Installation Guide
Compliance| FCC, CE, RCM, IC

GCC6011 Technical Specifications


Network Ports

| 2 x 2.5 Gigabit SFP port and 10 x Gigabit Ethernet ports

*Fixed 3 x WAN

---|---
Auxiliary Ports| 1xMicro-SD, 1xUSB 3.0, 1xReset
Memory| 2GB RAM, 32GB eMMC Flash
External Storage| Optional, up to 1T M.2 SSD
Router| 2.5Gbps
IPsec VPN Throughput| 1Gbps
NAT Sessions| 160K
IDS/IPS| 900Mbps
PBX| Up to 100 users/25 concurrent calls (default 12/4)
Mounting| Desktop/Wall/Rack-mounting
Material| Metal
LEDs| 12 x single LEDs and 1 x RGB LED for device tracking and status indication
Connection Type| DHCP, Static IP, PPPoE, PPTP, L2TP


Network Protocols

| IPv4, IPv6, IEEE802.1Q,IEEE 802.1p, IEEE802.1x, IEEE802.3, IEEE 802.3u, IEEE 802.3x,IEEE802.3ab
QoS| VLAN, TOS

Support multiple traffic classes, filter by port, IP address, DSCP, and policing App QoS: Application/protocol monitoring and traffic statistics

VoIP Prioritization

Firewall| DDNS, Port Forwarding, DMZ, UPnP, DoS & Spoofing defense, traffic rules, NAT, ALG DPI, Anti-Virus, IPS/IDS, SSL deep inspection
| Content Control: DNS Filtering, Web url/class/content filtering, Application identification and control
---|---




VPN

|

  • IPsec VPN
  • N Client-to-Site / Site-to-Site
  • IPSec Encryption: 3DES, AES
  • IPSec Authentication: MD5, SHA-1, SHA2-256
  • IPSec Key Exchange: Main/Aggressive Mode, Pre-shared Key, DH Groups 1/2/5/14
  • IPSec Protocols: ESP
  • IPSec NAT Traversal
  • PPTP VPN Server / Client
  • PPTP Encrpytion: MPPE 40-bit, 128-bit
  • PPTP/L2TP Authentication: MS-CHAPv1/2
  • L2TP Client-to-Site
  • OpenVPN® Server / Client
  • OpenVPN® Encryption: AES, DES
  • OpenVPN® Authentication: MD5, SHA-1, SHA2-256, SHA2-384, SHA2-512
  • OpenVPN® Certificate: RSA
  • WireGuard

Network Management| GDMS, Local Web GUI, CLI (Console, Telnet) and SNMP (v1/ v2c/v3)
Max AP/Clients| Up to 150 GWN APs; Up to 500 Clients
Power and Green Energy Efficiency| Universal power adaptor included: Input 100-240VAC 50-60Hz Output: 48VDC 1A (48W)

4 x PoE out ports IEEE802.3af/at

Max. PoE Wattage : 36W

Environmental| Operation: 0°C to 45°C Storage: -30°C to 60°C

Humidity: 5% to 95% Non-condensing

Physical| Unit Dimension: 280 x 180 x 44 mm

Unit Weight: 1200g

Entire Package Dimension: 366 x 211 x 53 mm

Entire Package Weight: 1600g


Package Content

| GCC6010/GCC6011, Universal Power Supply, Rack mount kit (Only GCC6011), Quick Installation Guide
Compliance| FCC, CE, RCM, IC

INSTALLATION

Before deploying and configuring the GCC601X(W) device, the device needs to be properly powered up and connected to the network. This section describes detailed information on the installation, connection, and warranty policy of the GCC601X(W) device.

Package Content

GCC601X(W) 1
Power Adaptor 1
Ethernet Cable With GCC6010W only.
Rack Mount Kit with GCC6011 only.
Simplified Quick Installation Guide 1
--- ---

GCC6010/GCC6011 Package Content

GCC6010W Package Content

Note:
Check the package before installation. If you find anything missing, contact your system administrator.

Connect Your GCC601X(W) Device

Safety Compliances

The GCC601X(W) complies with FCC/CE and various safety standards. The GCC601X(W) power adapter is compliant with the UL standard. Use the universal power adapter provided with the GCC601X(W) package only. The manufacturer’s warranty does not cover damages to the device caused by unsupported power adapters.

Warranty

If the GCC601X(W) device was purchased from a reseller, please contact the company where the device was purchased for replacement, repair, or refund. If the device was purchased directly from Grandstream, contact our Technical Support Team for an RMA (Return Materials Authorization) number before the product is returned. Grandstream reserves the right to remedy the warranty policy without prior notification.

Warning
Use the power adapter provided with the GCC601X(W) device. Do not use a different power adapter as this may damage the device. This type of damage is not covered under warranty.

Connecting GCC601X

1 2.5G SFP Port
2 USB 3.0
3 Ethernet Port
4 DC48V
5 RESET
6 Micro SD
7 Ground Terminal
8 Kensington Lock

Connecting GCC601XW

1 LED Indicators
2 NET Ports
3 USB 3.0 Port
4 Micro SD
5 Sync APs Button
6 DC12V
7 RESET Button

HOME

Overview
In this section, the user can view general information about the GCC60XX device. The information displayed includes basic information like the device name, hardware version, firmware version, MAC address, IP address, part number, serial number, boot version, uptime, and system time.
It also shows the firmware version of each module and whether a new firmware update for a module is detected.
In addition to that, it shows the general system performance of the device by displaying the CPU load rate, the storage performance rating, the percentage of the memory utilized.

Topology
In this section, the administrator can view the topology of the Grandstream networking device connected to the GCC device.

When clicking on the highlighted icon below, the user can view the device details and settings

To filter the types of devices that are shown on the topology click on

System Settings
In this section, the user can configure settings related to the general operations of the device.

Basic Settings
In this configuration tab, the user can define certain information about the GCC device. This includes device name, country/region, time zone, NTP server, and language.

Manager Server Settings

Security Settings
In this section, the user will be able to configure different security-related settings. These settings are mainly related to securing user access to the device either locally or remotely.

Account Settings
This tab allows the user to configure his/her username, password, email, and mobile phone number.

Web Access
On this page, the administrator can configure to allow or prevent web access through the WAN port. The administrator can also configure the HTTPS port number used for web access.

SSH Access
In this section, the user can enable SSH remote access to the device, this includes SSH remote access as well.

Remote Access without Password
Enabling passwordless remote access allows you to access the device through the GDMS management platform without having to provide a username and password for authentication.

Schedule
This feature allows the creation of schedules that can be applied as rules to various components of the GCC device. This includes the Wi-Fi-embedded controller.
When the user creates a new schedule, this schedule can be used for, e.g., to determine when a Wi-Fi SSID is broadcasted and when it is not.

User Management
User Management allows the user to create users with various roles and privileges.

User Information
In this section, the user can create new users by clicking on the button.

__Username| Enter the username.

The username can consist of 4-64 characters, including letters, digits, and underscores.

---|---
Password| Enter the password.

The password can consist of 8-32 characters, need to contain 2 types of numbers/letters/special characters

__Email| Enter the email of the user.

The email entered should be limited between 1-64 characters

__Mobile Number| Enter the mobile number of the user.

The phone number is limited between 2-18 digits

__Role| Select the role of this user.

__

The role must be created first, before it’s assigned to the user under

Role
In this section, the user can create roles that can be assigned to different users. By default, the SuperAdmin role is pre-created and assigned to the default administrator account of the device. To create more roles, click on button.

Note
Please note that the SuperAdmin role cannot be assigned to other users. It’s an exclusive role for the default user of the device.

Email Settings
Setting the email client on the GCC60XX device allows the device to send emails directly to users and administrators. For example, when an extension is created on the PBX module and the email is entered in the extension’s user information, the user will receive an email stating the information that he/she can use to log into his/her extension.
The email feature is used to send emails for the following types of information:

  • Extension information
  • Remote registration of an extension
  • Wave welcome message
  • Missed calls notifications
  • Scheduled multimedia meetings
  • Scheduled meeting reports
  • Alert events
  • Emergency calls
  • Password reset emails

Email Settings
Configuring email settings on the GCC device allows the sending of notification emails. This deployment of a third-party SMTP server to transfer the emails to the configured email addresses.

TLS Toggle TLS On/Off
Email Template Sending Forma __
  • HTML: The emails will be sent in HTML format.
  • Plain Text: The emails will be sent as plain text.

SMTP Server| Enter the address of the SMTP server. The address can be either an IP address or a FQDN.
SASL Authentication| Enable Simple Authentication and Security Layer. When this option is disabled, the device will not try to use the username and password for mail client authentication. Most of the mail servers require authentication while some other private mail servers allow anonymous login, which requires disabling this option to send email as normal. For Microsoft Exchange Server, please disable this option.
Username| Enter the username created for the SMTP client.
Password| Enter the username created for the SMTP client.
Email To Fax| Monitors the inbox of the configured email address for the specified subject. If enabled, the IPPBX will get a copy of the attachment from the email and send it to the XXX extension by fax. The attachment must be in PDF/TIF/TIFF format.
Email-to-Fax Blacklist/Whitelist| The user can enable the Email-to- Fax Blacklist or Email-to-Fax Whitelist.
Email-to-Fax Subject Format| Select the email subject format to use for emails to fax. XXX refers to the extension that the fax will be sent to. This extension can only contain numbers.
Fax Sending Success/Failure Confirmation| Email address blacklist/whitelist for local extensions.
POP/POP3 Server Address/Port| Configure the POP/POP3 server address and port for the configured username

Example: pop.gmail.com

Display Name Specify the display name in the FROM header in the Email.
__Sender Specify the sender’s Email address.

For example: pbx@example.mycompany.com

Email Template
The user can customize the layout of the emails sent by the device to the various users. The device already provides a pre-configured layout that can be modified.

The user can click on the edit button to edit a specific template.

The user can use the text editor to change the layout, once that is done, the user can view the new layout by clicking on

Email Footer Hyperlink
The customize the links that are included in the footers, please navigate to System Settings > Email Settings > Email Footer Hyperlink
On the page, you can edit the text and the URL of each footer. You can add 3 additional footers if needed.

Email Send Log
Email send log is used to keep records of all the emails that have been sent from the GCC device.

SMS Settings
The SMS feature allows the user to send information over SMS to mobile numbers. Currently, the information which can be sent over SMS are the following:

  • Profile Code:
  • Verification Code:
  • Alarm Notification:

SMS Settings

Twilio

Enable SMS Toggle the slider to enable/disable SMS service.
SMS Carrier Select Twilio as the SMS Carrier.
Username Enter the username of the account of the carrier.
Auth Token Enter the authentication token generated on the carrier’s

site.
Message Server ID| Enter the ID of the message server of the carrier.
From| Configure the source number of the outgoing messages.

Amazon

Enable SMS Toggle the button to enable/disable SMS feature.
SMS Carrier Choose Amazon as the SMS carrier.
Region Choose your region.
  • **** US East (N. Virginia)
  • US East (Ohio)
  • US West (N. California)
  • US West (Oregon)
  • EU (Ireland)
  • EU (London)
  • EU (Paris)
  • EU (Frankfurt)
  • EU (Stockholm)
  •  EU (Milan)
  • Asia Pacific (Hong Kong)
  • Asia Pacific (Mumbai)

|

  • Asia Pacific (Singapore)
  • Asia Pacific (Sydney)
  • Asia Pacific (Jakarta)
  • Asia Pacific (Tokyo)
  • Asia Pacific (Seoul)
  • Asia Pacific (Osaka)
  • South America (Sao Paulo)
  • China (Beijing)
  • China (Ningxia)
  • Canada (Central)
  • Middle East (Bahrain)
  • Middle East (UAE)
  • Africa (Cape Town)
  • AWS GovCloud (US-West)
  • AWS GovCloud (US-East)
  • US ISO East
  • US ISOB East (Ohio)
  • US ISO West
  • New List Item

---|---
Username| Configure your Amazon account ID.
Password| Configure your Amazon account password.

SMS Template
In the “SMS Template” tab, the user can view and edit templates of the SMS messages sent by the GCC device.

SMS Delivery Log
The “SMS Delivery Log” tab displays information about all the SMS messages that have originated from the GCC device.

PBX Upgrades
On this page, the user can manage the various licenses which can be uploaded to the GCC device.

PBX Upgrades

Maintenance

Upgrade
When a new firmware is released for the GCC device, the user can use the “Upgrade” page to update the firmware of the GCC device using different methods of updating the firmware.
There are three methods of upgrading the firmware which are listed below.

  • Official Online Upgrade: This method allows upgrading directly from the Grandstream firmware server. The administrator can click “Detect New Version” to check for any new firmware releases. When a new firmware version is available, the administrator can proceed with upgrading the device.
  • Allow DHCP Options 43 and 66 to Override Server: If enabled, DHCP options 66 and 43 will override the upgrade and provisioning settings, if disabled, use the configured server path to request firmware information by default. Note: In the official online upgrade mode, “Detect New Version” uses the official default address, and this configuration does not take effect.
  • Check/Download New Firmware at Bootup: When it is turned on, firmware detection will be performed every time the device is started. If a new firmware version is detected, it will automatically download and upgrade
  • Scheduled Upgrade: Specifies a specific schedule for the device to check for new firmware and install them.
  • Upgrade via Network: Using this method, the user can choose a specific upgrade method and configure a server address that hosts the firmware files.
  • Upgrade via Manual Upload: Using this method, the user can upload the firmware file directly on the web UI of the device.

Important

  • When uploading the firmware image to the device, please ensure that you are using the correct firmware image.
  • Before upgrading the firmware of the device, please perform a full backup of the configuration of the device to avoid any configuration loss after the upgrade.

Backup & Restore
On the “Backup & Restore” page, the user can back up the data of the GCC device. When backing up the data, the user can choose the data of the GCC modules to be backed up.

Factory Reset
On this page, the user can factory reset the GCC unit

Factory Reset
Notification Center
The Notification Center allows the user to view and configure notifications of the events that occur on the GCC device. To access the notification center, please access the main page of the GCC web UI and then click on the Notification Center tab.

Notification Settings
To set the notifications of the GCC device, click on .
On this page, the user can enable notifications for certain events on the GCC. In addition to generating the notification on the web UI, the user can configure an email address to which email notifications are sent.

Note
To use the email notification feature, please ensure that the Email Settings on the GCC are configured successfully.

NETWORKING
The Networking module of GCC601X(W) includes network-related configuration mainly VPN, Multi-WAN, and traffic management. It also allows users to configure all the standard routing configurations such as VLAN, port forwarding, etc.

Click on the icon to access.

FIREWALL
The firewall module of GCC601X(W) is a Next-Generation Firewall (NGFW) that secures users’ network environment by providing defense against the most advanced network attacks as it supports anti-virus and intrusion prevention (IDS/IPS) with frequent signature library updates and also supports SSL proxy to filter HTTPS URL.

Click on the icon to access.

NETWORK NODES
Network nodes refer to individual devices or components such as switches and access points that form the interconnected infrastructure of the network. These nodes provide data points for analysis, which helps centralize the monitoring and configuration of the device performance, security, and overall network features. The GCC601X(W) offers an embedded controller for both the wireless access points and the GWN-managed network switches to provide the user with a global overview of his network infrastructure.

Click on the icon to access.

PBX
The integrated IPPBX module in the all-in-one convergence device the GCC601X(W) provides a communication and collaboration solution for enterprises that do not require expanded telephony capabilities. It offers the same features that are provided by Grandstream IPPBX solution, the UCM6300, to ensure cost-effective and efficient collaboration among professionals.

Click on the icon to access.

UC ENDPOINTS
The UC endpoints configuration module contains all the settings and tools to manage and control the unified communication endpoints, including devices ranging from IP phones, Video phones, and Wi-Fi phones, to security facility access devices such as the IP cameras and the door systems. The GCC601X(W) with its VoIP devices and IPC devices management modules offers a centralized way to manage, provision, and control all your on-premise UC endpoint devices.

Click on the icon to access.

CHANGELOG
This section documents significant changes from previous versions of user manuals for GCC601x. Only major new features or major document updates are listed here. Minor updates for corrections or editing are not documented here.

Firmware version 1.0.1.8 (PBX version 1.0.25.11)
This is the initial version.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GRANDSTREAM User Manuals