COMMSCOPE FDH-3000 Enhanced Mini FDH Installation Drawing Instruction Manual
- August 16, 2024
- CommScope
Table of Contents
FDH-3000 Enhanced Mini FDH Installation Drawing
Product Information
Specifications:
- Model: Mini FDH
- Size: A2 0.100
- Material: See Notes
- Finish: See Notes
Product Usage Instructions:
Installation:
-
Mount the Mini FDH on a wall or pole using the provided
wall/pole mounting bracket. -
Ensure the grounding lug is properly connected.
Cable Routing:
Refer to the splitter chassis and swing frame for proper cable
routing. Use distribution strain relief for cables within the
specified diameter range.
Feeder and Distribution Trays:
-
Mount up to five splice trays for both feeder and distribution
at the top of the cabinet. -
Mount up to six distribution splice trays in the lower splice
tray holder. Refer to the identification label on each splice tray
for details.
FAQ:
Q: How many splice trays can be mounted in the Mini FDH?
A: Up to five splice trays for both feeder and distribution can
be mounted at the top of the cabinet. Additionally, up to six
distribution splice trays can be mounted in the lower splice tray
holder.
Q: How should I route cables in the Mini FDH?
A: Proper cable routing guidance can be found in the splitter
chassis and swing frame sections of the user manual. Use
distribution strain relief for cables within the specified diameter
range.
1
2
3
4
5
6
7
8
9
10
REVISIONS
REV
CMO
DATE
APPROVED
A
40177787CMO 22-AUG-2023 A.MAYA
A
A
12.51 REF
B
B
155 $REF
25.30 REF
C
C
7.93 REF
8.50 REF
D
D
9.17 REF WITH MOUNTING
BRACKET
13.00 REF
E
E
F
F
23.98 REF
25.98 REF
TOLERANCES
COMMSCOPE, INC.
SAP MATERIAL MASTER
SEE TABLE
FINISH
MATERIAL
G
G
SEE NOTES
SEE NOTES
SYMBOLOGY AGREES WITH ASME Y14.5M – 2009. ALL SHEETS
ARE THE SAME REVISION AND STATUS.
DRAFTER
O.BARRIENTOS
CHECKER
A. MAYA
TITLE
MINI FDH, INSTALLATION DRW
ENGINEER
SIZE
SCALE DOCUMENT NO.
H
A. MAYA
A2 0.125 860638095 H
CMO 40177787CMO
© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of
COMMSCOPE, INC. and may be used only for the specific purpose authorized in
writing by COMMSCOPE, INC.
ALL SURFACES WORK AREA: NCC
MODEL
DRAWING
SHEET
VERSION STATUS REVISION VERSION STATUS REVISION 1 OF 4
00
00
RE
A
1
2
3
4
5
6
7
8
9
10
SAP-ENTERPRISE-A2-2016-3RD.FRM
1
2
3
4
54 INCH SPLITTER CABLE ROUTING
A
SPLITTER CHASSIS
B
C
D
E SWINGFRAME
F
PARKING LOT PANEL
G SPLICE TRAYS
H
SAP-ENTERPRISE-A2-2016-3RD.FRM
1
DETAIL A (SPLICE VERSION CABINET SHOWN WITH OPENED
SWINGFRAME FOR REFERENCE ONLY)
2
3
4
5
6
7
8
9
10
FEEDER CABLE ASSIGNMENTS
FIBERS 1-8 FIBERS 9-12 FIBERS 13-36 (IF APPLICABLE)
SPLITTER SLOTS 1-8 SPLITTER SLOTS 5-8 (SECOND COLUMN OF SPLITTER INPUTS) A
PASS-THROUGH PORTS 13-36
SPLITTER SLOT 8
DETAIL A
B
SPLITTER SLOT 1
C
D PASS-THROUGH PORTS
E
F
DISTRIBUTION STRAIN RELIEF FOR CABLES THAT ARE 0.51 TO 0.71 INCHES IN DIAMETER
DISTRIBUTION STRAIN RELIEF FOR CABLES THAT ARE 0.35 TO 0.63 INCHES IN
DIAMETER
G
COMMSCOPE, INC.
TITLE
MINI FDH, INSTALLATION DRW
SIZE
SCALE DOCUMENT NO.
A2 0.100 860638095 H
© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of
COMMSCOPE, INC. and may be used only for the specific purpose authorized in
writing by COMMSCOPE, INC.
DRAWING
SHEET
VERSION STATUS REVISION 2 OF 4
00
RE
A
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
COMMON
TIE
A
POINT
SPLITTER INPUT FIBERS
B 2
HOOK AND PILE STRAP
MAKE TWO LOOPS AROUND TRAY HOLDER
COMMON TIE
POINT
DISTRIBUTION PORT FIBERS
FEEDER SPLICE TRAY
DISTRIBUTION SPLICE TRAYS
A
MAKE TWO LOOPS AROUND TRAY HOLDER
B
HOOK AND PILE STRAP
C
1
C
FEEDER CABLE
FIBERS
D
D
DISTRIBUTION CABLE FIBERS
E
E
F
F
G
H
SAP-ENTERPRISE-A2-2016-3RD.FRM
1
NOTES:
1 UP TO FIVE SPLICE TRAYS FOR BOTH FEEDER AND DISTRIBUTION ARE MOUNTED IN THE
SPLICE TRAY HOLDER AT THE TOP OF THE CABINET. UP TO SIX DISTRIBUTION SPLICE
TRAYS ARE MOUNTED IN THE LOWER SPLICE TRAY HOLDER. REFER TO IDENTIFICATION
LABEL ON EACH SPLICE TRAY.
2
3
4
5
6
© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of
COMMSCOPE, INC. and may be used only for the specific purpose authorized in
writing by COMMSCOPE, INC.
7
8
G
COMMSCOPE, INC.
TITLE
MINI FDH, INSTALLATION DRW
SIZE
SCALE DOCUMENT NO.
A2 0.100 860638095 H
DRAWING
SHEET
VERSION STATUS REVISION 3 OF 4
00
RE
A
9
10
1
2
3
4
5
6
7
8
9
10
4.82 REF
.21 REF
1.24 REF
A
A
1.50 REF
1.25 REF
1.50 REF
B
6.00 REF
8.50
REF
B
14.06 REF
C
C
D
E GROUNDING LUG
F
SCREW PROVIDED AS ACCESORY
G
WALL/POLE MOUNTING BRACKET
H INSTALL WALL/POLE MOUNTING BRACKET ON POLE OR WALL
1
2
3
SAP-ENTERPRISE-A2-2016-3RD.FRM
2.30 REF
1.24 REF
D
1.15 REF
.90 REF
MOUNTING BRACKET
E
F
SLOT FOR BELT INSTALLATION
G
COMMSCOPE, INC.
TITLE
MINI FDH, INSTALLATION DRW
SIZE
SCALE DOCUMENT NO.
A2 0.250 860638095 H
© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of
COMMSCOPE, INC. and may be used only for the specific purpose authorized in
writing by COMMSCOPE, INC.
DRAWING
SHEET
VERSION STATUS REVISION 4 OF 4
00
RE
A
4
5
6
7
8
9
10