COMMSCOPE FDH-3000 Enhanced Mini FDH Installation Drawing Instruction Manual

August 16, 2024
CommScope

FDH-3000 Enhanced Mini FDH Installation Drawing

Product Information

Specifications:

  • Model: Mini FDH
  • Size: A2 0.100
  • Material: See Notes
  • Finish: See Notes

Product Usage Instructions:

Installation:

  1. Mount the Mini FDH on a wall or pole using the provided
    wall/pole mounting bracket.

  2. Ensure the grounding lug is properly connected.

Cable Routing:

Refer to the splitter chassis and swing frame for proper cable
routing. Use distribution strain relief for cables within the
specified diameter range.

Feeder and Distribution Trays:

  • Mount up to five splice trays for both feeder and distribution
    at the top of the cabinet.

  • Mount up to six distribution splice trays in the lower splice
    tray holder. Refer to the identification label on each splice tray
    for details.

FAQ:

Q: How many splice trays can be mounted in the Mini FDH?

A: Up to five splice trays for both feeder and distribution can
be mounted at the top of the cabinet. Additionally, up to six
distribution splice trays can be mounted in the lower splice tray
holder.

Q: How should I route cables in the Mini FDH?

A: Proper cable routing guidance can be found in the splitter
chassis and swing frame sections of the user manual. Use
distribution strain relief for cables within the specified diameter
range.

1

2

3

4

5

6

7

8

9

10

REVISIONS

REV

CMO

DATE

APPROVED

A

40177787CMO 22-AUG-2023 A.MAYA

A

A

12.51 REF

B

B

155 $REF

25.30 REF

C

C

7.93 REF

8.50 REF

D

D

9.17 REF WITH MOUNTING
BRACKET

13.00 REF

E

E

F

F

23.98 REF

25.98 REF

TOLERANCES

COMMSCOPE, INC.
SAP MATERIAL MASTER
SEE TABLE

FINISH

MATERIAL

G

G

SEE NOTES

SEE NOTES

SYMBOLOGY AGREES WITH ASME Y14.5M – 2009. ALL SHEETS
ARE THE SAME REVISION AND STATUS.

DRAFTER
O.BARRIENTOS

CHECKER

A. MAYA

TITLE

MINI FDH, INSTALLATION DRW

ENGINEER

SIZE

SCALE DOCUMENT NO.

H

A. MAYA

A2 0.125 860638095 H

CMO 40177787CMO

© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of COMMSCOPE, INC. and may be used only for the specific purpose authorized in writing by COMMSCOPE, INC.

ALL SURFACES WORK AREA: NCC

MODEL

DRAWING

SHEET

VERSION STATUS REVISION VERSION STATUS REVISION 1 OF 4

00

00

RE

A

1

2

3

4

5

6

7

8

9

10

SAP-ENTERPRISE-A2-2016-3RD.FRM

1

2

3

4

54 INCH SPLITTER CABLE ROUTING

A

SPLITTER CHASSIS

B

C

D

E SWINGFRAME
F

PARKING LOT PANEL

G SPLICE TRAYS

H

SAP-ENTERPRISE-A2-2016-3RD.FRM

1

DETAIL A (SPLICE VERSION CABINET SHOWN WITH OPENED
SWINGFRAME FOR REFERENCE ONLY)

2

3

4

5

6

7

8

9

10

FEEDER CABLE ASSIGNMENTS

FIBERS 1-8 FIBERS 9-12 FIBERS 13-36 (IF APPLICABLE)

SPLITTER SLOTS 1-8 SPLITTER SLOTS 5-8 (SECOND COLUMN OF SPLITTER INPUTS) A
PASS-THROUGH PORTS 13-36

SPLITTER SLOT 8

DETAIL A

B

SPLITTER SLOT 1

C

D PASS-THROUGH PORTS
E

F

DISTRIBUTION STRAIN RELIEF FOR CABLES THAT ARE 0.51 TO 0.71 INCHES IN DIAMETER

DISTRIBUTION STRAIN RELIEF FOR CABLES THAT ARE 0.35 TO 0.63 INCHES IN
DIAMETER

G
COMMSCOPE, INC.
TITLE
MINI FDH, INSTALLATION DRW

SIZE

SCALE DOCUMENT NO.

A2 0.100 860638095 H

© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of COMMSCOPE, INC. and may be used only for the specific purpose authorized in writing by COMMSCOPE, INC.

DRAWING

SHEET

VERSION STATUS REVISION 2 OF 4

00

RE

A

5

6

7

8

9

10

1

2

3

4

5

6

7

8

9

10

COMMON

TIE

A

POINT

SPLITTER INPUT FIBERS

B 2

HOOK AND PILE STRAP
MAKE TWO LOOPS AROUND TRAY HOLDER

COMMON TIE
POINT
DISTRIBUTION PORT FIBERS

FEEDER SPLICE TRAY

DISTRIBUTION SPLICE TRAYS

A
MAKE TWO LOOPS AROUND TRAY HOLDER
B
HOOK AND PILE STRAP

C

1

C

FEEDER CABLE

FIBERS

D

D

DISTRIBUTION CABLE FIBERS

E

E

F

F

G

H

SAP-ENTERPRISE-A2-2016-3RD.FRM

1

NOTES:
1 UP TO FIVE SPLICE TRAYS FOR BOTH FEEDER AND DISTRIBUTION ARE MOUNTED IN THE SPLICE TRAY HOLDER AT THE TOP OF THE CABINET. UP TO SIX DISTRIBUTION SPLICE TRAYS ARE MOUNTED IN THE LOWER SPLICE TRAY HOLDER. REFER TO IDENTIFICATION LABEL ON EACH SPLICE TRAY.

2

3

4

5

6

© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of COMMSCOPE, INC. and may be used only for the specific purpose authorized in writing by COMMSCOPE, INC.

7

8

G
COMMSCOPE, INC.
TITLE
MINI FDH, INSTALLATION DRW

SIZE

SCALE DOCUMENT NO.

A2 0.100 860638095 H

DRAWING

SHEET

VERSION STATUS REVISION 3 OF 4

00

RE

A

9

10

1

2

3

4

5

6

7

8

9

10

4.82 REF

.21 REF
1.24 REF

A

A

1.50 REF

1.25 REF

1.50 REF

B

6.00 REF

8.50

REF

B

14.06 REF

C

C

D

E GROUNDING LUG
F

SCREW PROVIDED AS ACCESORY
G
WALL/POLE MOUNTING BRACKET

H INSTALL WALL/POLE MOUNTING BRACKET ON POLE OR WALL

1

2

3

SAP-ENTERPRISE-A2-2016-3RD.FRM

2.30 REF

1.24 REF

D

1.15 REF

.90 REF

MOUNTING BRACKET

E

F

SLOT FOR BELT INSTALLATION

G
COMMSCOPE, INC.
TITLE
MINI FDH, INSTALLATION DRW

SIZE

SCALE DOCUMENT NO.

A2 0.250 860638095 H

© 2024 CommScope, Inc. Confidential
NOTICE: These drawings and specifications are the proprietary property of COMMSCOPE, INC. and may be used only for the specific purpose authorized in writing by COMMSCOPE, INC.

DRAWING

SHEET

VERSION STATUS REVISION 4 OF 4

00

RE

A

4

5

6

7

8

9

10

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CommScope User Manuals

Related Manuals