Specifications

  • Model: CPS815RMS/CPS1615RMS
  • Manufacturer: Cyber Power Systems (USA), Inc.
  • Location: Indoor use only, in dry locations
  • Installation: Vertical or Horizontal
  • Power Cord: AC Power Cord included

Product Usage Instructions

Safety Precautions

  • Before installing or operating the RackBar Surge, please read and follow these safety precautions.
  • Install in a dry indoor location free of conductive contaminants.
  • Avoid excessive moisture or heat during installation.
  • Do not use for medical or life support equipment.

Installation

  1. Mounting Bracket Installation:
    • Install the screws (M4X4) in holes diagonal from each other on the mounting bracket.
  2. Electrical Installation:
  3. Receptacle Evaluation:
  * Ensure the plug type of your RackBar unit matches the wall receptacle type being used.
  * RackBar must be plugged into a three-wire grounded wall receptacle only.
2. Plug the RackBar into the wall receptacle.
3. Attach equipment, making sure not to exceed the unit’s maximum current load.

Horizontal Installation

  1. Mounting Bracket Installation:
    • Install the screws (M4X4) in holes diagonal from each other on the mounting bracket.

Verify Protection

After installation, verify that both the Grounded and Protected LED indicators are illuminated. This indicates proper grounding and surge protection.

FAQ

Q: Can I use the RackBar Surge Protector outdoors?

A: No, the product is designed for indoor use only in dry locations to ensure safety and performance.

Q: How do I register my product for warranty?

A: To register your product and avail benefits like warranty certification and free technical support, visit www.CyberPowerSystems.com/registration.

OVERVIEW

Front View

Rear View

  1. Mounting Bracket
  2. Circuit Breaker
  3. Front Outlets (CPS1615RMS)
  4. Grounded LED Indicator
  5. Protected LED Indicator
  6. Rear Outlets
  7. AC Power Cord

PRODUCT REGISTRATION

  • Thank you for purchasing a CyberPower product. This product is designed to provide unsurpassed power protection, operation, and performance during the lifetime of the product.
  • Please take a few minutes to register your product at: www.CyberPowerSystems.com/registration.
  • Registration certifies your product’s warranty, confirms your ownership in the event of a product loss or theft, and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.

TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Use only in dry locations and only indoors.
  • DO NOT plug into another relocatable power tap.
  • DO NOT “daisy chain” surge protectors.
  • DO NOT use any aquarium equipment.
  • DO NOT use if properly grounded outlets are not available.
  • DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and the electrical service panel.
  • DO NOT use for medical or life support equipment. This device features internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.
  • WARNING To prevent the risk of fire or electric shock, this RKBS should be installed in a temperature and humidity-controlled indoor area free of conductive contaminants. Do not install this RackBar where excessive moisture or heat is present.

SAFETY PRECAUTIONS

Read the following before installing or operating the RackBar Surge:

  • ONLY use the supplied hardware to attach the mounting brackets.
  • The RackBar must only be plugged into a three-wire, grounded outlet on a circuit protected by a fuse or circuit breaker. Connection to any other type of power outlet may result in a shock hazard.
  • DO NOT use extension cords or adapters with this RackBar.
  • NEVER install a RackBar, or associated wiring or equipment, during a lightning storm.
  • Ensure that the power cord, plug, and socket are in good condition.
  • This device features internal protection that will disconnect the surge protective component at the end of its useful life but will maintain power to the load —now unprotected.
  • If this situation is undesirable for the application, follow the manufacturer’s instructions for replacing the device.
  • CAUTION! Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and the electrical service panel.
  • CAUTION! To prevent the risk of fire or electric shock, this RackBar should be installed in a temperature and humidity-controlled indoor area free of conductive contaminants. Do not install this RackBar where excessive moisture or heat.

INTRODUCTION

Unpacking

Inspect the RackBar surge upon receipt.

The box should contain the following:

  • (a) RackBar Surge Unit
  • (b) Mounting Brackets: (1) Horizontal set, (1) Vertical set
  • (c) Bracket Mounting Screws (4) Flat Head M4
  • (d) User Manual

INSTALLATION

Vertical Installation

  1. Mounting Bracket Installation – Install the screws (M4 X 4) in holes diagonal from each other.
  2. RackBar Mounting – Install the RackBar using the fasteners that are compatible with the rack.

Horizontal Installation

  1. Mounting Bracket Installation – Install the screws (M4 X 4) in holes diagonal from each other.
  2. Mounting – Install the RackBar using the fasteners that are compatible with the rack.

ELECTRICAL INSTALLATION

  1. Receptacle evaluation
    • Ensure that the plug type of your RackBar unit (e.g. NEMA 5-15P) matches the wall receptacle type that you are using.
    • RackBar must be plugged into a three-wire, grounded wall receptacle only.
    • The wall receptacle must also be connected to an appropriate branch circuit/main with fuse or circuit breaker protection.
    • Connection to any other type of wall receptacle may result in a shock hazard.
  2. Plug the RackBar into the wall receptacle.
  3. Attach equipment
    • Before attaching equipment, it is important to calculate the total load that you will be placing on the RackBar. It is extremely important not to exceed the RackBar’s maximum current load (as outlined in the Specifications section).
    • To determine your total load, simply add up the amperage of your devices and ensure that it does not exceed the unit’s capacity.
  4. Verify protection
    • Verify that both the Grounded and Protected LEDs are illuminated. This means that the RackBar is properly grounded and is protecting the equipment from surges.

TECHNICAL SPECIFICATIONS

Model Name CPS815RMS / CPS1615RMS

Input
Voltage| 125 V
Frequency| 60 Hz
Maximum Current| 15 A
Circuit Breaker| 15 A
Plug Type| NEMA 5-15P
Power Cord Length| 15 ft. / 4.6 m
Output
Voltage| 125 V
Maximum Current| 15 A
Outlet Type| NEMA 5-15R
Surge Protection & Filtering
EMI / RFI Filtration| Yes
Surge Suppression| 1800 J
Management & Communications
** LED Indicators| Grounded (green) Protected (green)
Physical**
Dimensions Height/Width/Depth| 19.0 x 1.75 x 4.6 in.

483 x 44 x 117 mm

Environmental
Operating Relative Humidity| 0 to 95% Non-condensing
Operating Elevation| 9,843 ft. / 3,000 m
Operating Temperature| 32°F to 95°F / 0°C to 35 °C
Safety Approvals
Certifications| UL 1363 / UL 1449 / RoHS

TROUBLESHOOTING

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Canadian Compliance Statement

CAN ICES-3 (B)/NMB-3(B)

LIMITED WARRANTY

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE

Where Can I Get More Information?

  • The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.
  • For further information please feel free to contact CyberPower at: Cyber Power Systems (USA), Inc.
  • 4241 12th Ave E., STE 400, Shakopee, MN 55379; call us at 877-297-6937; or submit a web ticket online at cyberpowersystems.com/support.
  • WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
  • ©2024 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners.
  • CyberPower reserves the right to change, without notice, marketing programs, product offerings, and specifications. www.cyberpowersystems.com

Documents / Resources

| CyberPower CPS815RMS CPS1615RMS Rack Bar Surge Protectors [pdf] User Manual
CPS815RMS, CPS1615RMS, CPS815RMS CPS1615RMS Rack Bar Surge Protectors, CPS815RMS CPS1615RMS, Rack Bar Surge Protectors, Bar Surge Protectors, Surge Protectors, Protectors
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals