Specifications

  • Product Name : LPD – Low Profile Directional Recessed 6 LED Downlight MRI Compatible
  • Model Numbers: 1-07-000027, 1-07-000035, 1-07-000105, 1-07-000106
  • Light Engine Replacement Part Numbers: 5-07-000009, 5-07-000017

Product Usage Instructions

Installation

LPD Recessed Can Installation – Suspended Ceiling

  1. Turn off the power supply and remove the ceiling tile.
  2. Extend bar hangers to fit between the T-Grid and snap/screw into place.
  3. To secure the recessed can position it on bar hangers and squeeze tabs to lock in place.
  4. Wire the luminaire per the Electrical Connections section.
  5. Locate the center of the proposed opening in the ceiling tile and mark the intended location of the luminaire. Cut appropriate 6 1/2 diameter opening in the ceiling tile.
  6. Place ceiling tile in the T-bar grid.
  7. Connect the light engine to the recessed can housing.
  8. Secure the Quick Connect connector onto the top of the luminaire to the connector inside the recessed can.
  9. Pinch the torsion spring clips into a V shape and slide the luminaire into the recessed can securing the clips into the brackets located inside the can.

Recessed Can Installation – New Construction (Wood)

  1. Turn off the power supply.
  2. Extend bar hangers to fit between joists and secure with appropriate hardware.
  3. Wire luminaire per Electrical Connections section.
  4. Position recessed can on hanger bars. To secure the fixture position in the ceiling, squeeze tabs into hanger bars to lock fixture in place on bars.
  5. Secure the Quick Connect connector onto the top of the luminaire to the connector inside the recessed can.
  6. Pinch the torsion spring clips into a V shape and slide the luminaire into the recessed can securing the clips into the brackets located inside the can.

FAQ

  • Q: Can this luminaire be used with emergency exits?
  • A: No, this device is not intended for use with emergency exits.

Important Safety Instructions

When using electrical equipment, basic safety precautions should always be followed including the following:
Read And Follow All Safety Instructions

  1. Warning: This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and require-ments, consult a qualified electrician. Attention:
  2. Warning: This equipment is not for use in hazardous combustible atmospheres as defined by the National Electrical Code.
  3. Danger: Risk of shock – Disconnect power before installation.
  4. This device is not intended for use with emergency exits.
  5. Use only with a Class 2 power unit.
  6. Type IC.
  7. Inherently protected.

Save These Instructions For Future Reference

Installation:

LPD Recessed Can Installation

  • Step 1:
    Turn off the power supply and remove the ceiling tile.

  • Step 2:
    Extend bar hangers to fit between the T-Grid and snap/screw into place. See Diagram 1.

  • Step 3:
    To secure the recessed can position it on bar hangers and squeeze tabs to lock in into place. See Diagram 1.

  • Step 4:
    Wire the luminaire per the Electrical Connections section.

  • Step 5:
    Locate the center of the proposed opening in the ceiling tile and mark the intended location of the luminaire. Cut an appropriate 6 1/2” diameter opening in the ceiling tile.

  • Step 6:
    Place ceiling tile in the T-bar grid.

  • Step 7:
    Connect the light engine to the recessed can housing.

  • Step 8 :
    Secure the Quick Connect connector on to the top of the luminaire to the connector inside the recessed can. See Diagram 2.

  • Step 9:
    Pinch the torsion spring clips into a “V” shape and slide the luminaire into the recessed can securing the clips into the brackets located inside the can. See Diagram 3.

Recessed Can Installation – New Construction (Wood)

  • Step 1:
    Turn off the power supply.

  • Step 2:
    Extend bar hangers to fit between joists and secure with appropriate hardware (not provided). Hangers should be level with the bottom of the joists. See Diagram 1.

  • Step 3:
    Wire luminaire per Electrical Connections section.

  • Step 4:
    Position recessed can on hanger bars. To secure the fixture position in the ceiling, squeeze tabs into hanger bars to lock the fixture in place on bars. See Diagram 1.

  • Step 5:
    Secure the Quick Connect connector onto the top of the luminaire to the connector inside the recessed can. See Diagram 2.

  • Step 6:
    Pinch the torsion spring clips into a “V” shape and slide the luminaire into the recessed can securing the clips into the brackets located inside the can. See Diagram 3.

Electrical Connections

Step 1:
Using customer-supplied conduit, cord, or Ethernet cable make the following connections with 90°C minimum-rated wire connectors.
DC Wiring

  1. Connect + 36 VDC supply lead to the Red positive lead
  2. Connect – 36 VDC supply lead to the Black negative lead.

Diagram 4 – Electrical Connections – 1-07-000006 and 1-07-000037

Ethernet Wiring

  1. Connect the CAT5, CAT5E or CAT6 Ethernet Cable from the 12/16 Channel Driver to the “In” port in the Luminaire 1.
  2. Connect the CAT5, CAT5E or CAT6 Ethernet Cable from the “Parallel Out” port of Luminaire 1 to the “Parallel In” port of Luminaire 2.
  3. All wires must be terminated to Standard T568B on both ends.
  4. Two (2) luminaires maximum per single output from 12/16 Channel Driver

Diagram 5 – Electrical Connections – 1-07-000005 and 1-07-000039

Directive 2012/19/EU (WEEE – Waste Electrical and Electronic Equipment): Information for Users
This product complies with EU Directive 2012/19/EU. The crossed-out wheeled bin symbol on the article means that at the end of its useful lifespan, this product must not be disposed of with your other household or municipal waste. This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment if not properly disposed of. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on natural resources, the user is responsible for delivering the appliance to an appropriate collection facility at the end of its useful lifespan. The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information on available collection facilities contact your local waste collection service or the place of purchase.

CONTACT

  • Amico Lights Corporation
  • 122-B East Beaver Creek Road, Richmond Hill, ON L4B 1G6, Canada
  • www.amico.com Toll-Free
  • Tel : 1.877.462.6426
  • Toll Free Fax :1.866.440.4986
  • Tel : 905.764.0800
  • Fax : 905.764.0862

ALT-INSTALL-MRI-LPD-DOWNLIGHT-RECESSED 01.18.2021