Amico DL6 Recessed 6 Inch Downlight Installation Guide
- August 6, 2024
- Amico
Table of Contents
Amico DL6 Recessed 6 Inch Downlight
Specifications
- Model : DL6 Recessed 6 Downlight
- MRI Compatible
- Variants:
- 1-07-000158 – 30K Ethernet
- 1-07-000159 – 30K DC Wiring
- 1-07-000160 – 35K Ethernet
- 1-07-000161 – 35K DC Wiring
- 1-07-000162 – 40K Ethernet
- 1-07-000163 – 40K DC Wiring
Product Usage Instructions
Installation – Suspended Ceiling:
- Turn off the power supply and remove the ceiling tile.
- Remove the reflector from the luminaire housing by removing the two screws from the inner flange and gently pulling the reflector straight down.
- Extend bar hangers to fit between the T-Grid and snap/screw into place. See Diagram 1. Note: Bar Hangers for this luminaire are of interlocking design to allow positioning of housing along entire length of bars.
- To secure the luminaire mounting frame, position on bar hangers and squeeze tabs to lock into place. See Diagram 1.
- Locate the center of the proposed opening in the ceiling tile and mark the intended location of the luminaire. Cut an appropriate 6 1/2” diameter opening in the ceiling tile.
- Wire the luminaire per the Electrical Connections section.
- Adjust the tabs to be flush with the ceiling tile and secure using the thumb screws as shown in Diagram 2.
- Place ceiling tile in T-bar grid aligning the hole of the luminaire with the cut out hole in the ceiling tile.
- Replace the reflector removed in Step 2.
Recessed Can Installation – New Construction (Wood):
- Turn off the power supply.
- Remove the reflector from the luminaire housing by removing the two screws from the inner flange and gently pulling the reflector straight down.
- Extend bar hangers to fit between joists and secure with appropriate hardware (not provided). Hangers should be level with the bottom of the joists. See Diagram 1.
- To secure the luminaire mounting frame, position on bar hangers and squeeze tabs to lock in to place. See Diagram 1.
- Adjust the tabs to be flush with the bottom of the proposed drywall and secure using the thumb screws.
- Wire luminaire per Electrical Connections section.
- Complete the drywall surface as intended.
- Replace the reflector removed in Step 2.
Electrical Connections:
Refer to Diagram 4 for specific electrical connections based on the variant of
the product you have.
Step 1:
Using customer-supplied conduit, cord, or Ethernet cable make the following
connections with 90°C minimum-rated wire connectors.
DC WHITE LIGHT WIRING – 1-07-000006 and 1-07-000037
- Connect + 24 VDC supply lead to the Red Positive lead.
- Connect – 24 VDC supply lead to the Black negative lead.
ETHERNET WIRING – 1-07-000005 and 1-07-000039
- Connect the CAT5, CAT5E or CAT6 Ethernet Cable from the 12/16 Channel Driver to the “In” port in the junction box.
- Connect the CAT5, CAT5E or CAT6 Ethernet Cable from the “Out” port of the first luminaire to the “In” port of the next Ethernet luminaire.
- All wires must be terminated to Standard T568B on both ends.
- Four (4) luminaires maximum per CAT output from 12/16 Channel Driver.
Important Safety Instructions
When using electrical equipment, basic safety precautions should always be followed including the following:
Read And Follow All Safety Instructions
-
Warning : This luminaire must be installed in accordance with the NEC or
your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. -
Warning : This equipment is not for use in hazardous combustible atmospheres as defined by the National Electrical Code.
-
Danger : Risk of shock – Disconnect power before installation.
-
Type IC
-
Inherently protected.
-
Use only with a Class 2 power unit.
Save These Instructions For Future Reference
DL6 Recessed Luminaire
- 1-07-000158 – 30K Ethernet
- 1-07-000160 – 35K Ethernet
- 1-07-000162 – 40K Ethernet
- 1-07-000159 – 30K DC Wiring
- 1-07-000161 – 35K DC Wiring
- 1-07-000163 – 40K DC Wiring
Directive 2012/19/EU (WEEE – Waste Electrical and Electronic Equipment):
Information for Users
This product complies with EU Directive 2012/19/EU. The crossed-out wheeled
bin symbol on the article means that at the end of its useful lifespan, this
product must not be disposed of with your other household or municipal waste.
This product has required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health and
the environment if not properly disposed. In order to avoid the dissemination
of those substances in our environment and to diminish the pressure on natural
resources, the user is responsible for delivering the appliance to an
appropriate collection facility at the end of its useful lifespan. The
separate collection and recycling of your waste equipment at the time of
disposal will help conserve natural resources and ensure that it is recycled
in a manner that protects human health and the environment. For more
information on available collection facilities contact your local waste
collection service or the place of purchase.
- Amico Lights Corporation
- 122-B East Beaver Creek Road, Richmond Hill, ON L4B 1G6, Canada
- www.amico.com
For informational purposes only. Content is subject to change.
ALT-INSTALL-MRI-DL6-DOWNLIGHT-RECESSED 01.22.2021
FAQ
Q: Is this product suitable for MRI environments?
A: Yes, this product is MRI-compatible, ensuring safe use in such
environments.
Q: Do I need any special tools for installation?
A: Basic tools such as a screwdriver may be needed for installation, but no
special tools are required.
References