NORA LIGHTING NM2-2RTLDC Trimless Mud Ring Owner’s Manual

August 5, 2024
NORA LIGHTING

NM2-2RTLDC

2″ M2 Trimless LED Downlight
Source: 8W or 10W LED
750lm or 900lm

Type
———————————————————
Project
———————————————————
Catalog No.
———————————————————
Notes


PRODUCT DESCRIPTION

2″ M2 trimless downlights features quality and convenience with easy installation for insulated or non-insulated applications. Each installation requires a mud plate that mounts to drywall and hold LED luminaire to ceiling without any housing.

FEATURES
  • No housing required – IC Air-Tight rated
  • Easy installation for remodel or new construction applications
  • Trimless mud plate required (NM2-TLMR-R)
  • Quick disconnect allows for extended lengths
  • Delivering up to 900 lumens
  • 2700K, 3000K or 4000K @ 90+ CRI
  • Triac or ELV dimming
  • 5-year limited warranty
  • ENERGY STAR certified
  • cETLus Listed for Damp Locations
SPECIFICATION

Construction: Die-cast aluminum trims available in matte black or matte powder white finish.

Air Flow Restriction: Luminaire has factory installed gasket to restrict airflow from room into ceiling plenum to <2CFM (cubic feet per minute) in accordance with ASTM-283 Air-Tight requirements.

Clearance: IC rated luminaires are rated for direct contact with insulation (not spray foam insulation), no minimum clearance is required.

Junction Box: Pre-wired junction box includes quick connect to LED fixtures for ease of installation. Junction box includes two 1/2″ trade size knockout and snap on cover with 18″ quick connect wire. Luminaire includes 6″ quick connect wire.
Maximum length between luminaire and driver is 40′. For longer remote driver remote run length, consult factory.

Mounting: No housing is required, patent pending mud plate (ordered separately) secures luminaire to ceiling.

ELECTRICAL

Input Voltage: 120V
Lumens / Wattage: 750lm / 8W or 900lm / 10W
Color Temperature: 2700K, 3000K or 4000K
Color Rendering Index: 90+ CRI
Operating Temperature: 0-30°C
Dimming: Triac or ELV
Click Here or check complete dimmer list at www.NoraLighting.com in the “Compatibility” page under “Resources” tab

ACCESSORIES

NM2-TLMR-R: Trimless Mud Plate (required)
NF-R246: Universal New Construction Frame-In (optional)
NFC-R275: New Construction Frame-In with Collar (optional)
NMA-EW-4: 4′ Quick Connect Linkable Extension Cable (optional)
NMA-EW-10: 10′ Quick Connect Linkable Extension Cable (optional)

LABELS AND LISTINGS
  • cETLus Listed for Damp Locations

  • ENERGY STAR certified

  • 5-Year Limited Warranty

  • FCC compliant

  • Certified to the high efficacy requirements of California Title 24 JA8-2022

Performance Data

Part Number

| Lumens| CCT
NM2-2RTLDC6027MPW| 700lm|

2700K

NM2-2RTLDC8527MPW

| 817lm| 2700K
NM2-2RTLDC6030MPW| 746lm|

3000K

NM2-2RTLDC8530MPW

| 843lm| 3000K
NM2-2RTLDC6040MPW| 774lm|

4000K

NM2-2RTLDC8540MPW

| 935lm|

4000K

Delivered lumens will vary depending on finish

PRODUCT IMAGES AND DIMENSIONS

NM2-2RTLDC60               NM2-2RTLDC60
Matte Black                       Matte Powder White

Cut out: 2-¾”

NM2-2RTLDC85             NM2-2RTLDC85
Matte Black                     Matte Powder White

Cut out: 2-¾”

NM2-TLMR-R
Trimless Mud Plate


2″ M2 Trimless LED Downlight

Description Lumens / Wattage Color Temperature Finish
NM2-2RTLDC = 2″ M2 Trimless 60 = 750lm / 8W
85 = 900lm / 10W 27 = 2700K

30 = 3000K
40 = 4000K| BB = Matte Black
MPW = Matte Powder White


2″ M2 Trimless Mud Plate (Required)

Description

NM2-TLMR-R = Trimless Mud Plate


Optional Extension Cables

Description

NF-R246 = Universal New Construction Frame-In
NFC-R275 = New Construction Frame-In with Collar
NMA-EW-4 = 4′ Quick Connect Extension Cable
NMA-EW-10 = 10′ Quick Connect Extension Cable


Example: NM2-2RTLDC6030MPW / NM2-TLMR-R = 2″ M2 Trimless LED Downlight, 750lm / 8W, 3000K, Matte Powder White


013124P1

2″ M2 Trimless LED Downlight Accessories

Trimless Mud Plate

NM2-TLMR-R
Mounts trimless downlight with no exposed flange and no extension beyond ceiling plane.

Universal New Construction Frame-In

NF-R246
Universal new construction frame-in can be used to assist installing can-less recessed downlighting.

New Construction Frame-In with Collar

NFC-R275
New construction frame-in can be used to assist installing can-less recessed downlighting.

Quick Connect Extension Linkable Cables

NMA-EW-4                                  4’ Cable
NMA-EW-10                              10’ Cable
Use to extend the length between luminaire and driver enclosure. Can be connected together to create custom lengths. Maximum length between luminaire and driver is 40’. For longer remote driver remote run length, consult factory.


013124P2

PHOTOMETRICS

2″ M2 Trimless LED Downlight , 750lm / 8W

Test Information
Test Number: NTR2004R1
Part Number: NM2-2RTLDC6027MPW
Beam Spread: 42° Narrow Flood
Lumens: 700lm
Wattage: 7.86W
Efficacy: 89lpw
CCT / CRI: 2700K / 90 CRI
Spacing Criteria (0°-180°): 0.7
Spacing Criteria (90°-270°): 0.68

Polar Curve

Illuminance at a Distance

Distance from Luminaire

| FC at Nadir| Beam Diameter
---|---|---
4′| 74.4fc |

3′-1″

6′

| 33fc | 4′-7″
8′| 18.6fc |

6′-2″

10′

| 11.9fc | 7′-8″
12′| 8.3fc |

9′-4″

Zonal Lumen Summary

Zone

| Lumens| % Luminaire
---|---|---
0-30| 543|

77.7

0-40

| 617| 88.1
0-60| 679|

97.1

0-90

| 700| 100
90-180| 0|

0

0-180

| 700|

100

Candela Table

Vertical Angles

| Candela
---|---
0|

1190

5

| 1163
15|

873

25

| 422
35|

109

45

|

43


Test Information
Test Number: NTR2005R1
Part Number: NM2-2RTLDC6030MPW
Beam Spread: 43° Narrow Flood
Lumens: 746lm
Wattage: 7.83W
Efficacy: 95lpw
CCT / CRI: 3000K / 90 CRI
Spacing Criteria (0°-180°): 0.7
Spacing Criteria (90°-270°): 0.7

Polar Curve

Illuminance at a Distance

Distance from Luminaire

| FC at Nadir| Beam Diameter
---|---|---
4′| 77.9fc |

3′-1″

6′

| 34.6fc | 4′-8″
8′| 19.5fc |

6′-2″

10′

| 12.5fc | 7′-10″
12′| 8.7fc |

9′-4″

Zonal Lumen Summary

Zone

| Lumens| % Luminaire
---|---|---
0-30| 578|

77.5

0-40

| 657| 88.1
0-60| 725|

97.2

0-90

| 746| 100
90-180| 0|

0

0-180

| 746|

100

Candela Table

Vertical Angles

| Candela
---|---
0|

1246

5

| 1216
15|

938

25

| 455
35|

120

45

|

47


Test Information
Test Number: NTR2006R1
Part Number: NM2-2RTLDC6040MPW
Beam Spread: 44° Narrow Flood
Lumens: 774lm
Wattage: 7.76W
Efficacy: 100lpw
CCT / CRI: 4000K / 90 CRI
Spacing Criteria (0°-180°): 0.72
Spacing Criteria (90°-270°): 0.72

Polar Curve

Illuminance at a Distance

Distance from Luminaire

| FC at Nadir| Beam Diameter
---|---|---
4′| 79.3fc |

3′-2″

6′

| 35.3fc | 4′-10″
8′| 19.8fc |

6′-6″

10′

| 12.7fc | 8′-1″
12′| 8.8fc |

9′-8

Zonal Lumen Summary

Zone

| Lumens| % Luminaire
---|---|---
0-30| 605|

78.3

0-40

| 686| 88.6
0-60| 752|

97.2

0-90

| 774| 100
90-180| 0|

0

0-180

| 774|

100

Candela Table

Vertical Angles

| Candela
---|---
0|

1269

5

| 1245
15|

990

25

| 481
35|

126

45

|

46


Lumen Output Multipliers
Finish: Matte Black (0.86), Matte Powder White (1.00)


013124P3

2″ M2 Trimless LED Downlight , 900lm / 10W

Test Information
Test Number: NTR2127R1
Part Number: NM2-2RTLDC8527MPW
Beam Spread: 43° Narrow Flood
Lumens: 817lm
Wattage: 9.63W
Efficacy: 85lpw
CCT / CRI: 2700K / 90 CRI
Spacing Criteria (0°-180°): 0.7
Spacing Criteria (90°-270°): 0.7

Polar Curve

Illuminance at a Distance

Distance from Luminaire

| FC at Nadir| Beam Diameter
---|---|---
4′| 85.8fc |

3′-2″

6′

| 38.1fc | 4′-10″
8′| 21.4fc |

6′-4″

10′

| 13.7fc | 7′-11″
12′| 9.5fc |

9′-6″

Zonal Lumen Summary

Zone

| Lumens| % Luminaire
---|---|---
0-30| 642|

78.6

0-40

| 735| 90.0
0-60| 796|

97.3

0-90

| 816| 100
90-180| 0|

0

0-180

| 817|

100

Candela Table

Vertical Angles

| Candela
---|---
0|

1372

5

| 1341
15|

1029

25

| 511
35|

136

45

|

47


Test Information
Test Number: NTR2128R1
Part Number: NM2-2RTLDC8530MPW
Beam Spread: 43° Narrow Flood
Lumens: 843lm
Wattage: 9.52W
Efficacy: 89lpw
CCT / CRI: 3000K / 90 CRI
Spacing Criteria (0°-180°): 0.7
Spacing Criteria (90°-270°): 0.7

Polar Curve

Illuminance at a Distance

Distance from Luminaire

| FC at Nadir| Beam Diameter
---|---|---
4′| 88.4fc |

3′-2″

6′

| 39.3fc | 4′-10″
8′| 22.1fc |

6′-4″

10′

| 14.1fc | 7′-11″
12′| 9.8fc |

9′-5″

Zonal Lumen Summary

Zone

| Lumens| % Luminaire
---|---|---
0-30| 662|

78.6

0-40

| 758| 90.0
0-60| 820|

97.3

0-90

| 841| 99.8
90-180| 2|

0.2

0-180

| 843|

100

Candela Table

Vertical Angles

| Candela
---|---
0|

1415

5

| 1382
15|

1061

25

| 526
35|

140

45

|

48


Test Information
Test Number: NTR2129R1
Part Number: NM2-2RTLDC8540MPW
Beam Spread: 43° Narrow Flood
Lumens: 935lm
Wattage: 9.55W
Efficacy: 98lpw
CCT / CRI: 4000K / 90 CRI
Spacing Criteria (0°-180°): 0.7
Spacing Criteria (90°-270°): 0.7

Polar Curve

Illuminance at a Distance

Distance from Luminaire

| FC at Nadir| Beam Diameter
---|---|---
4′| 98.0fc |

3′-2″

6′

| 43.6fc | 4′-10″
8′| 24.5fc |

6′-3″

10′

| 15.7fc | 7′-11″
12′| 10.9fc |

9′-5″

Zonal Lumen Summary

Zone

| Lumens| % Luminaire
---|---|---
0-30| 734|

78.6

0-40

| 841| 90.0
0-60| 910|

97.3

0-90

| 933| 99.8
90-180| 2|

0.2

0-180

| 935|

100

Candela Table

Vertical Angles

| Candela
---|---
0|

1569

5

| 1533
15|

1176

25

| 584
35|

156

45

|

53


Lumen Output Multipliers
Finish: Matte Black (0.87), Matte Powder White (1.00)


013124P4

6505 Gayhart Street, Commerce, CA 90040
Tel 800.686.6672 | www.noralighting.com | e-mail: nora@noralighting.com
© 2024 Nora Lighting, Inc. All rights reserved. Specifications subject to change without notice.