WARNING
This Quick Start Guide is not a substitute for reading the operator’s
manual. To reduce the risk of injury or death, user must read and understand
operator’s manual before using this product.
TOOLS YOU WILL NEED
Fresh clean unleaded gasoline (not included)
Funnel (included)
4-stroke engine oil (included)
BEFORE STARTING
Add engine oil.
a. Remove the oil service door to access the oil dipstick.
b. Remove oil dipstick.
c. Using the supplied 4-cycle engine oil and funnel, slowly add engine
oil to the engine until full.
d. Do not overfill. If oil level is too high, oil will drain out through the fill plug.
Add unleaded gasoline to gas tank.
a. Unscrew gas cap on top of tank
b. Slowly add gasoline into the fuel tank. The gasoline level should NOT be higher than the red maximum fill ring.
c. Secure gas cap
Connect LPG tank.
a. Connect included LPG hose to standard LPG tank and hand tighten.
b. Connect other end of LPG hose to generator and hand tighten.
c. Test connections with soapy water to make sure there are no leaks.
DANGER
Using a generator indoors
CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or
smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.|
Only use OUTSIDE and far away from windows, doors, and vents.
Avoid other generator hazards.
READ MANUAL BEFORE USE.
STARTING PROCEDURE
Make sure all loads are disconnected from the generator and the ECO mode
switch is in the OFF position.
Select fuel source.
3a. For manual start, place the battery switch in the on position (I). Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling out from the inverter
3b. For electric start, place the battery switch in the on position (I). Press the start button until the engine starts
3c. For remote start, place the battery switch in the on position (I). Press the ON button on the remote until the engine starts
Connect loads to the control panel receptacles
SHUTDOWN PROCEDURE
- Make sure all loads are disconnected from the generator
- Put the engine run/stop switch in the RUN position and pull choke
NOTE: This unit has a GASOLINE OFF (PROPANE) setting that can be used before storing the unit for long periods of time. Refer to the user manual for details.
INVERTER MECHANICAL SPECIFICATIONS
Model Number| Running Watts| Peak Watts| Fuel Tank Size(L/G)| Rated
Speed(RPM)| Ignition Type| Engine Dips (cc)| Oil Capacity (L)| Oil Type| THD
---|---|---|---|---|---|---|---|---|---
iGen5000DF/ iGen5000DFc| 3900 gas/3500 LPG| 5000 gas/4500 LPG| 12.8/3.4| 3600|
TCI| 224| 0.6| 10W30| £ 3%
MAINTENANCE SCHEDULE
Following the maintenance schedule is important to keep the inverter in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals. Refer to the Maintenance section in the Owners Manual to find out how to properly perform maintenance.
TABLE 1: MAINTENANCE SCHEDULE
Maintenance Item| Before Every Use| After First 25 Hours or First Month of
Use| After 50 Hours of Use or Every 6 Months| After 100 Hour of Use or Every 6
Months| After 300 Hours of Use or Every Year
---|---|---|---|---|---
Engine Oil| Check Level| Change1| Change| –| –
Air Filter| –| –| Clean2| –| Replace
Air Filter| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
Fuel Filter| –| –| –| Replace3| –
Valve Clearance| –| –| –| Inspect/Adjust3| –
- Change oil every month when operating under heavy load or in high temperatures.
ENGINE OIL | ACEITE DEL MOTOR | HUILE POUR MOTEURS
Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is an acceptable substitute for conventional oil.
SPARK PLUG REPLACEMENT
Westinghouse Model Westinghouse No de pièce Westinghouse|
**Torch| ****Bosch| ****NGK| ****Autolyze**
---|---|---|---|---
iGen5000DF/ iGen5000DFc| F7RTC| WR7BC| BPR6HS| 284