AROHA SM03 Safety Pro Mini Smoke Detector Instruction Manual
- August 2, 2024
- AROHA
Table of Contents
AROHA SM03 Safety Pro Mini Smoke Detector
Product Information
- Brand: Aroha Electronics
- Model: Aroha SM03
- Type: Safety Pro Mini Smoke Detector
- Country of Origin : The Netherlands
- Power Source: Lithium Battery (non-replaceable)
- Sound Level : 85 dB
Product Usage Instructions
A. Activate/Deactivate the Detector
The device is deactivated by default. To activate, follow these steps:
- Twist the mounting bracket counterclockwise off the detector by aligning the lines.
- Power on: Set the switch on the back of the detector to use the supplied stick.
- Power off : Set the switch on the back of the detector to use the supplied stick.
B. Test Your Alarm
To test the alarm:
- Press the test button.
- The alarm should sound if working correctly.
- If no sound, refer to the troubleshooting section.
C. LED Indicators
Interpret LED indicators as follows:
- Test status: Red LED flashes once every second.
- Silence mode: Red LED flashes once every 8 seconds.
- Low battery status: Red LED flashes once every 60 seconds and 1 probe every 60 seconds.
- Fault status: Red LED flashes once every 40 seconds and 1 beep every 40 seconds.
D. Silence Mode
To use silence mode:
- Identify the source of the alarm.
- Press the test button to activate silence mode.
- The red LED flashes once every 8 seconds during silence mode.
- The detector resets automatically after 10 minutes.
Dear customer,
- Thank you for choosing Aroha, a Dutch brand bringing safety to your home.
- Scan the QR code or visit www.aroha.nl/manual for step-by-step instructions to safely install your detector, see the installation videos and read the FAQ. Please read the manual carefully before operating the detector to ensure safe and proper use.
- Feel free to contact us with your problems, concerns, and suggestions at contact@aroha.nl.
Aroha
- ADDRESS: Postbus 135, 4900AC Oosterhout, The Netherlands
- www.aroha.nl
- contact@aroha.nl
Visit our online store to see the full collection of design, mini, smart, and/or interlinked smoke alarms, carbon monoxide (CO) alarms, and combination 2-in-1 smoke and carbon monoxide alarms: WWW.AROHA.NL
Aroha Safety Pro Mini Smoke Detector manual
Please read the manual carefully to ensure safe, proper use and store it in
a safe place for future reference. Scan the QR-code or visit
www.aroha.nl/manual for step-by-step
instructions with video to safely install your detector and consult the FAQ.
A. Activate/Deactivate the detector
The device is deactivated by default before leaving our factory. Twist the
mounting bracket counterclockwise off the detector by aligning the lines
(Figure 1).
- Power on: Set the switch on the back of the detector to “ON” using the supplied stick (Figure 2).
- Power off: Set the switch on the back of the detector to “OFF” using the supplied stick (Figure 2).
CAUTION
- The installation instructions must be followed strictly to avoid unsafe conditions.
- Do not paint your detector.
- The battery cannot be replaced; do not try to replace the battery as this will render the detector unusable and can cause a fire due to the high-capacity lithium battery.
B. Test your alarm
- The detector is tested before leaving the factory to ensure proper operation.
- You may test the detector yourself by pressing the test button. The alarm will sound if the detector is working well. If there is no sound, refer to the “Trouble shooting” section.
CAUTION
- DO NOT test your detector using an open flame. This may damage the detector or ignite combustible materials and start a structural fire.
- DO NOT stand close to the detector when the alarm is sounding. Exposure at close range may be harmful to your ears.
- Test the detector at least once a month.
C. LED indicators
- Test status: Red LED flashes once every second.
- Silence mode: Red LED flashes once every 8 seconds.
- Low battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.
- Fault status: Red LED flashes once every 40 seconds and 1 beep every 40 seconds.
D. Silence mode
Silence mode should only be used if the source of the alarm is known and
safe. Press the test button to set the silence mode. During silence mode, the
red LED light flashes once every 8 seconds. The detector is automatically
reset after 10 minutes.
CAUTION
Before using the silence mode, identify the source of the smoke and be certain
a safe condition exists.
E. Mount the detector Determine correct mounting location
- Check Figures 3, 4, and 5 for correct mounting locations. Most EU countries require smoke detectors on all floors and escape routes.
- Smoke spreads horizontally after rising to the ceiling, so install the detector in the middle of the ceiling.
- If the length of the room or the hall is beyond 10 meters, you need to install multiple alarms.
Do not mount detectors on these locations
- Areas with high humidity (e.g. kitchens, bathrooms), insects, dust/dirt, easily polluted and high temperature.
- Within 1.5 meters of lamps, next to air outlets (e.g. doors/windows), fans, and central heating.
- In the top of a room with sloping roofs, in the corner of the room or in other dead-air spaces.
- Places with difficult access, making it difficult to operate the test function.
Mounting instructions
- Step 1 : Twist the mounting bracket counterclockwise off the detector. Step 2: Put the bracket on the mounting position and mark the 2 screw holes.
- Step 3 : Drill two 5mm mounting holes and insert the two plastic anchor plugs with a hammer.
- Step 4 : Screw the mounting bracket to the ceiling or the wall.
- Step 5: Attach the detector to the mounting bracket and turn clockwise to lock the detector.
F. Maintenance and cleaning
There are a few steps you need do to keep it working properly:
- Test the detector at least once a month.
- Do not paint the detector. Paint will seal the vents and interfere with the sensor’s ability to detect smoke.
- Never attempt to disassemble the detector to clean inside. This will damage the detector and possibly render it unuseable.
- Clean the detector at least once a month to remove dust, dirt or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the detector.
G. Trouble shooting
- The detector does not sound when testing: Check whether the smoke detector is activated.
- The detector beeps every 60 seconds and red LED flashes: The battery is low; the detector needs to be replaced. Contact us on contact@aroha.nl to replace it if the warranty is still in place.
- The detector beeps every 40 seconds : Clean the smoke detector, by using a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke detector. If the issue continues, the detector is malfunctioning. Contact us on contact@aroha.nl to replace it if the warranty is still in place.
- False alarms triggered intermittently or when residents are cooking, taking showers, etc.: Check whether there is any danger from smoke and/or fire nearby. Once the danger has been ruled out, press the test button to set the silent mode. To prevent future false alarms, clean and maintain the smoke detector as directed. Also consider installing the smoke detector in a different location if it gives a false alarm due to water vapor, for example.
Product specifications
A. Package contents
- Photoelectric smoke detector(s)
- Mounting bracket
- Screw kit
- User manual
- Stick to flip the switch
B. Product specifications
- Battery: 3VDC CR123A Li-Ion
Battery 1600mAh (Included & Non-replacable)
- Alarm Volume: >85 dB(A) at 3 meters
- Alarm Sensitivity: 0.17 dB/m
- Low Battery: 2.6 ± 0.1 V
- Silence Time: Approx. 10 minutes
- Comply to Standard: 14604:2005/AC:2008
C.Product certifications
Download DOC/DOP at www.aroha.nl.
1008
DOP: INV-SM03-Rev0
Comply to Standard EN14604:2005/AC:2008
Warranty
Two years of warranty
- During the specified warranty period of 2 years after purchase, we will repair or replace any defective detector that is returned. This warranty shall not apply to the detector if it has been damaged, modified, neglected, abused or altered after the date of purchase or if it fails to operate due to improper maintenance, and the unit will not be replaced or repaired. Please contact us at contact@aroha.nl regarding the warranty.
- The manufacturer shall have no liability for any personal injury, property damage or any special, incidental, contingent or consequential damage of any kind resulting from gas leakage, smoke, fire or explosion.
Visit www.aroha.nl/manual for step-by-step instructions to safely install your detector, see the installation videos and read the FAQ.
Frequently Asked Questions
- Q: Can the battery be replaced?
- A: The battery in the detector is non-replaceable. Attempting to replace it can render the detector unusable and pose a fire hazard due to the high-capacity lithium battery.
- Q: How often should I test the detector?
- A: It is recommended to test the detector at least once a month to ensure proper functionality.
References
Read User Manual Online (PDF format)