AROHA SM11 Smoke Detector User Manual

June 16, 2024
AROHA

AROHA SM11 Smoke Detector

AROHA-SM11-Smoke-Detector-PRODUCT

Product Information

Specifications

  • Brand: Aroha Electronics
  • Model: Aroha SM11
  • Country of Origin: Netherlands
  • Power Source: Lithium battery (non-replaceable)
  • Alarm Sound Level: 85dB

FAQs

  • How can I install my Aroha SM11 detector safely?

    • Please refer to the step-by-step instructions and installation  video available at www.invisionretail.com/manual for detailed guidance on safely installing your detector.
  • Can I replace the battery of the Aroha SM11 detector?

    • No, the battery of the Aroha SM11 detector is non-replaceable.
      Attempting to replace the battery may render the detector unuseableV and can cause a fire due to the high-capacity lithium battery.
  • How often should I test my Aroha SM11 detector?

    • It is recommended to test your Aroha SM11 detector at least once a month to ensure proper operation.
  • Can I use an open flame to test the detector?

    • No, using an open flame to test the detector may damage it or ignite combustible materials, potentially causing a structural fire. Please use the test button provided for testing purposes.

Introduction

Dear customer,

  • Thank you for choosing Aroha, a Dutch brand bringing safety in your home.
  • Scan the QR-code or visit www.invisionretail.com/manual for the step-by-step instructions to safely install your detector, see the installation video’s and read the FAQ.
  • Please read the manual carefully before operating the detector and to ensure safe and proper use.
  • Feel free to contact us with your problems, concerns and suggestions on contact@invisionretail.com.

Aroha

Instructions, video & FAQ

AROHA-SM11-Smoke-Detector-FIG-1

Visit our online store to see the full collection of design, smart and/or interlinked smoke alarms, carbon monoxide (CO) alarms, and combination 2-in-1 smoke and carbon monoxide alarms. WWW.INVISIONRETAIL.COM

AROHA-SM11-Smoke-Detector-FIG-2

Aroha SM11 User manual

  • Please read the manual carefully to ensure safe, proper use and store it in a safe place for future reference.
  • Scan the QR-code or visit www.invisionretail.com/manual for the step-by-step instructions with video to safely install your detector and consult the FAQ.

Activate/Deactivate the detector

The device is deactivated by default before leaving our factory. Beforethe detector can be used, it must be activated.

  • Power on: Press and hold the test button (= centre front of detector) until the red LED indicator lights up and a beep sounds; this takes at least 10 seconds. After you release the test button the detector is activated and can be used.
  • Power off: Press and hold the test button (= centre front of detector) until the red LED indicator lights up twice and a beep sounds twice; this takes at least 10 seconds. After you release the test  button the detector is deactivated and cannot be used.

CAUTION

  • The installation instructions must be followed strictly to avoid unsafe conditions.
  • Do not paint your detector.
  • The battery cannot be replaced; do not try to replace the battery as this will render the detector unuseable and can cause a fire due to the high-capacity lithium battery.

Test your alarm

  • Test the detector to ensure proper operation  by pressing the test button (= centre front of  detector).
  • The alarm will sound if the  detector is working well. If there is no sound, refer to the “Trouble shooting” section.

CAUTION

  • DO NOT test your detector using an open flame. This may damage the detector or ignite  combustible materials and start a structural fire.
  • DO NOT stand close to the detector when the alarm is sounding. Exposure at close range may  be harmful to your ears.
  • Test the detector at least once a month.

LED indicators And Silence mode

LED indicators

  • Normal status: Green LED flashes once every 60 seconds.
  • Test status: Red LED flashes once every second.
  • Silence mode: Red LED flashes once every 8 seconds.
  • Low battery status: Red LED flashes once every 60 seconds and 1 beep every 60 seconds.
  • Fault status: Red LED flashes once every 40 seconds and 1 beep every 40 seconds.

Silence mode

Silence mode should only be used if the source of the alarm is known and safe. Press the test  button (= centre front of detector) to set the silence mode. During silence mode, the red LED light  flashes once every 8 seconds. The detector is automatically reset after 10 minutes.

CAUTION: Before using the silence mode, identify the source of the smoke and be certain a safe condition exists.

Mount the detector

Determine correct mounting location

AROHA-SM11-Smoke-Detector-FIG-6

  • Check figure 3, 4 and 5 for correct mounting locations. Most EU countries require smoke detectors on all floors and escape routes.
  • Smoke spreads horizontally after rising to the ceiling, so install the detector in middle of the ceiling.
  • If the length of the room or the hall is beyond 10 meters, you need to install multiple alarms.

Do not mount detector on these locations

  • Areas with high-humidity (e.g. kitchens, bathrooms), insects, dust/dirt, easily polluted and high-temperature.
  • Within 1.5 meters of lamps, next to air outlets (e.g. doors/windows), fans and central heating.
  • In top of room with sloping roofs, in the corner of the room or other dead-air spaces.
  • Places with difficult access, making it difficult to operate the test function.

Mounting instructions

  • Step 1: Twist the mounting bracket counterclockwise off the detector.
  • Step 2: Put the bracket on the mounting position and mark the 2 screw holes.
  • Step 3: Drill two 5mm mounting holes and insert the two plastic anchor plugs by hammer.
  • Step 4: Screw the mounting bracket to the ceiling or the wall.
  • Step 5: Attach the detector to the mounting bracket and turn clockwise to lock the detector.

Maintenance and cleaning

There are a few steps you need do to keep it working properly:

  • Test the detector at least once a month.
  • Do not paint the detector. Paint will seal the vents and interfere with the sensor’s ability to detect smoke.
  • Never attempt to disassemble the detector to clean inside. This will damage the detector and possibly render it unuseable.
  • Clean the detector at least once a month to remove dust, dirt or debris. Use a vacuum cleaner with a soft brush and vacuum all sides and covers of the detector.

Trouble shooting

  • The detector does not sound when testing: Check whether the smoke detector is activated.
  • The detector beeps every 60 seconds and red LED flashes: The battery is low; the detector needs to be replaced. Contact us on contact@invisionretail.com to replace it if the warranty is still in place.
  • The detector beeps every 40 seconds: Clean the smoke detector, by using a vacuum cleaner with a soft brush and vacuum all sides and covers of the smoke detector. If the issue continues, the detector is malfunctioning. Contact us on contact@invisionretail.com to replace it if the warranty is still in place.
  • False alarms triggered intermittently or when residents are cooking, taking showers, etc: Check whether there is any danger from smoke and/or fire nearby. Once danger has been ruled out, press the test button to set the silent mode. To prevent future false alarms, clean and maintain the smoke detector as directed. Also consider installing the smoke detector in a different location if it gives a false alarm due to water vapor, for example.

Warranty

Two years of warranty

During the specified warranty period of 2 years after purchase, we will repair or replace any defective detector that is returned. This warranty shall not apply to the detector if it has been damaged, modified, neglected, abused or altered after the date of purchase or if it fails to operate due to improper maintenance, and the unit will not be replaced or repaired. Please contact us at contact@invisionretail.com regarding the warranty. The manufacturer shall have no liability for any personal injury, property damage or any special,  incidental, contingent or consequential damage of any kind resulting from gas leakage, smoke, fire or explosion.

Product specifications

Package contents

AROHA-SM11-Smoke-Detector-FIG-7

  • Photoelectric smoke detector(s)
  • Mounting bracket
  • Screw kit
  • User manual

Product specifications

  • Power: 3V DC
  • Battery: CR14505 Lithium Battery 1600mAh (Included)
  • Operation Current: <30uA (standby) <70mA (alarm)
  • Alarm Volume: >85 dB(A) at 3 meters
  • Alarm Sensitivity: 0.09 – 0.17 dB/m
  • Low Battery: 2.6 ± 0.1 V
  • Silence Time: Approx. 10 minutes
  • Comply to Standard: EN14604:2005/AC:2008

Product certifications

CE: 1008
DOP: INV-SM11-Rev0

Comply to Standard EN14604:2005/AC:2008

References