AJAX Socket Type F User Manual

July 31, 2024
ajax

Socket Type F

Specifications:

  • Type: Wireless Indoor Smart Plug
  • Plug Type: European plug adapter (Type F)
  • Max Load: 2.5 kW
  • Communication: Jeweller radio protocol
  • Communication Distance: Up to 1,000 m in line of sight
  • Compatibility: Ajax hubs only
  • Operating Modes: Pulse or Bistable
  • Firmware Version: 5.54.1.0 and higher

Product Usage Instructions:

Functional Elements:

  • Two-pin socket
  • LED border
  • QR Code
  • Two-pin plug

Operating Principle:

The maximum resistive load is 2.5 kW. When using inductive or
capacitive loads, the maximum switching current is reduced to 8 A
at 230 V~.

Socket (type F) with firmware version 5.54.1.0 and higher can
operate in pulse or bistable mode. Users can select the relay
contact status:

  • Normally closed – Stops supplying power when activated, and
    resumes when turned off.

  • Normally open – Supplies power when activated, and stops
    feeding when turned off.

For Socket (type F) with firmware version below 5.54.1.0, it
only works in bistability mode with a normally open contact.

How to Find Out the Firmware Version:

In the Ajax app, users can check the power or amount of energy
consumed by electrical appliances connected via Socket (type
F).

Connecting:

Before connecting the device:

  1. Switch on the hub and check its Internet connection (the logo
    glows white or green).

  2. Install the Ajax app. Create the account, add the hub to the
    app, and create at least one room.

  3. Ensure that the hub is not armed and not updating by checking
    its status in the Ajax app.

FAQ:

Q: Can Socket (type F) be used with ocBridge Plus or uartBridge

integration modules?

A: No, Socket (type F) operates with Ajax hubs only and does not
support connecting via ocBridge Plus or uartBridge integration
modules.

Q: How can users check the firmware version of Socket (type

F)?

A: In the Ajax app, users can find the firmware version
information for Socket (type F).

Socket (type F) User manual
Updated July 15, 2024
Socket (type F) is a wireless indoor smart plug with the power-consumption meter for indoor use. Designed as a European plug adapter (type F), Socket (type F) controls the power supply of electrical appliances with a load of up to 2.5 kW. Socket (type F) indicates the load level and is protected from overload. Connecting to the Ajax system via a secured Jeweller radio protocol, the device supports communication at a distance of up to 1,000 m in line of sight.
Socket (type F) operates with Ajax hubs only and does not support connecting via ocBridge Plus or uartBridge integration modules.
Use scenarios to program actions of automation devices (Relay, WallSwitch, LightSwitch, WaterStop or Socket (type F)) in response to an alarm, Button press, a schedule or temperature, humidity, CO2 concentration levels change. A scenario can be created remotely in the Ajax app.

Scenarios by the Button pressing are created in the Button settings, scenarios by the humidity and CO2 concentration levels are created in the LifeQuality settings.
If the device is offline, it will not execute the scenario as it misses the scenario trigger (e.g., during a power outage or when the connection between the hub and device is lost). Use case: The automated action is scheduled for 10 a.m., so it must start at 10 a.m. The electrical power goes out at 9:55 a.m. and is restored ten minutes later. The automation scenario won’t start at 10 a.m. and will not start immediately after the power is back on. This scheduled action is missed.
How to create and configure a scenario in the Ajax system
Three Socket models are available: with a UK plug Socket (type G) and Socket Plus (type G) with an European plug Socket (type F).
Buy smart plug Socket (type F)
Functional Elements
1. Two-pin socket.

2. LED border. 3. QR Code. 4. Two-pin plug.
Operating Principle

00:00

00:04

Socket (type F) switches on/off the 110­230 V~ power supply, opening one pole by the user command in the Ajax app or automatically according to a scenario, Button press, a schedule.

Socket (type F) is protected against voltage overload (exceeding the range of 184­253 V~) or overcurrent (exceeding 11 A). In case of overload, the power supply switches off, resuming automatically when voltage restored to normal values. In case of overcurrent, the power supply switches off automatically, but can only be restored manually by the user command in the Ajax app.

The maximum resistive load is 2.5 kW. When using inductive or capacitive loads, the maximum switching current is reduced to 8 A at 230 V~.

Socket (type F) with firmware version 5.54.1.0 and higher can operate in pulse or bistable mode. With this firmware version you can also select the relay contact status:

Normally closed — Socket (type F) stops supplying power when activated, and resumes when turned off. Normally open — Socket (type F) supplies power when activated, and stops feeding when turned off. Socket (type F) with firmware version below 5.54.1.0 only works in bistability mode with a normally open contact. How to find out the firmware version of the device? In the app, users can check the power or amount of energy consumed by electrical appliances connected via Socket (type F).
At low loads (up to 25 W), current and power consumption indications may be displayed incorrectly due to hardware limitations.
Connecting
Before connecting the device
1. Switch on the hub and check its Internet connection (the logo glows white or green).
2. Install the Ajax app. Create the account, add the hub to the app, and create at least one room.
3. Make sure that the hub is not armed, and it does not update by checking its status in the Ajax app.
Only users with administrator rights can add a device to the app.
To pair Socket (type F) with the hub
1. Click Add device in the Ajax app.

2. Name the device, scan it, or enter the QR code manually (located on the case and packaging), select the room.
3. Plug the Socket (type F) into a power outlet and wait 30 seconds — the LED frame will flash green.
4. Click Add — the countdown will begin. 5. Socket (type F) will appear in the list of hub devices. The device statuses update depends on the ping interval set in the hub settings. The default value is 36 seconds. If the device failed to pair, wait 30 seconds and then retry. For detection and pairing to occur, the device should be located in the coverage area of the hub’s wireless network (at the same object). A connection request is transmitted only at the moment of switching on the device. When pairing the hub with the smart plug that was previously paired with another hub, make sure that it was unpaired with a former hub in the Ajax app. For correct unpairing, the device should be in the coverage area of the hub’s wireless network (at the same object): when unpaired correctly, the Socket (type F) LED frame continuously blinks green. If the device has not been correctly unpaired, do the following to connect it to the new hub: 1. Make sure that Socket (type F) is outside the coverage area of the former
hub’s wireless network (the indicator of the communication level between the device and the hub in the app is crossed out).

2. Select the hub with which you want to pair Socket (type F). 3. Click Add Device. 4. Name the device, scan or enter the QR code manually (located on the case
and packaging), select the room. 5. Click Add — the countdown will begin.
. During the countdown, for a few seconds, give Socket (type F) at least 25 W load (by connecting and disconnecting a working kettle or lamp).
7. Socket (type F) will appear in the list of hub devices.
Socket (type F) can be connected to one hub only.

Icons
The icons show some of the Socket (type F) states. You can view them in the Ajax app on the Devices tab.

Icon

Meaning

Jeweller signal strength — displays the signal strength between the hub and the smart plug.

The device is connected via a radio signal range extender.

Current protection is activated. Voltage protection is activated. Temperature protection is activated. The device was not transferred to the new hub.

Learn more

States

The states include information about the device and its operating parameters. Socket (type F) states are available in the Ajax app. To access them:
1. Go to the Devices tab. 2. Select Socket (type F) in the list.

Parameter Jeweller Signal Strength Connection via Jeweller ReX Active

Value Jeweller is a protocol for the transmission of events and alarms. The field displays the Jeweller signal strength between a hub or a range extender and Socket (type F). Recommended values: 2­3 bars.
More about Jeweller
Connection status between a hub or a range extender and a smart plug:
Online — the smart plug is connected.
Offline — no connection with the smart plug.
Displays the connection status of the plug to
the radio signal range extender:
Online — the smart plug is connected.
Offline — no connection with the smart plug. The field is displayed if the plug is operated via the radio signal range extender.
The smart plug state:
Yes — plug contacts are closed. The electrical appliance connected to the plug is energized.
No — plug contacts are open. No current is being supplied to the appliance connected

Current
Voltage Current Protection Voltage Protection Power

to the plug.
The field is displayed if Socket (type F) operates in the bistable mode.
The value of current commuted by Socket (type F).
The frequency of value updates depends on the Jeweller settings. The default value is 36 seconds.
Values of current are displayed in increments of 10 mA.
The value of voltage commuted by Socket (type F).
The frequency of value updates depends on the Jeweller settings. The default value is 36 seconds.
Values of voltage are displayed in increments of 1 V AC.
Indicates whether the overcurrent protection is enabled. Voltage protection state:
On — voltage protection is enabled. The plug switches off automatically when the power supply voltage exceeds 184­253 V~.
Off — voltage protection is disabled.
The smart plug will automatically continue to operate when the voltage returns to normal.
We recommend deactivating this protection if the Socket is connected to 110 V~ mains.
The power consumption of an appliance connected to the smart plug.
The frequency of value updates depends on the Jeweller settings. The default value is 36 seconds.

Electric Energy Consumed
Permanent Deactivation
One-Time Deactivation Firmware Device ID Device No.

The power consumption values are displayed in increments of 1 W.
The electric power consumed by the device connected to the Socket (type F).
The frequency of value updates depends on the Jeweller settings. The default value is 36 seconds.
The counter is reset when the Socket (type F) lose the power.
Shows the state of the device deactivation function:
No — the device operates normally, responds to commands, executes scenarios, and transmits all events.
Entirely — the device is excluded from the system operation. The smart plug doesn’t respond to commands, doesn’t run scenarios, and doesn’t transmit events.
Learn more
The status of the device one-time deactivation setting:
No — the device operates in normal mode.
Entirely — the device is completely excluded from system operation until the first disarm. It does not execute system commands or report alarms and other events.
Learn more
Smart plug firmware version. Device ID/serial number. It can be found on the plug box and its body. The number of the smart socket loop (zone).

Settings
To change the smart plug settings in the Ajax app:
1. Go to the Devices tab. 2. Select Socket (type F) in the list. 3. Go to Settings by clicking on the gear icon . 4. Set the required parameters. 5. Click Back to save the new settings.

Setting Name
Room Notifications

Value Socket (type F) name. It is displayed in SMS and notifications in the event feed.
To change the name, click on the text field.
The name can contain 12 Cyrillic characters or up to 24 Latin characters.
Selection of Socket (type F) virtual room.
The room name is displayed in SMS and notifications in the event feed.
Selecting the plug notifications:
When switched on/off — the user receives notifications from the device switching its state.
When scenario executed — the user receives notifications about the execution of scenarios involving this device.
The setting is available when Socket (type F) is connected to all hubs (except for the Hub model) with firmware version OS Malevich 2.15 or higher and in apps of the following versions or higher:
Ajax Security System 2.23.1 for iOS

Current Protection Voltage protection Operating Mode
Contact State

Ajax Security System 2.26.1 for Android
Ajax PRO: Tool for Engineers 1.17.1 for iOS
Ajax PRO: Tool for Engineers 1.17.1 for Android
Ajax PRO Desktop 3.6.1 for macOS
Ajax PRO Desktop 3.6.1 for Windows
If enabled, power supply switches off if the current load exceeds 11A, if disabled the threshold is 16A (or 13A for 5 seconds).
When this option is active, the power of the appliance connected to the plug will be cut off if voltage exceeds 184­253 V~.
We recommend deactivating this protection if the Socket is connected to 110 V~ mains.
Selecting Socket (type F) operation mode:
Pulse — when activated, Socket (type F) generates a pulse of a given duration.
Bistable — Socket (type F), when activated, changes the state of contacts to the opposite (e.g., closed to open) when activated.
Settings are available with firmware version 5.54.1.0 and higher.
Selection of the normal state of the plug contacts:
Normally closed (NC) — the plug contacts are closed in the normal state. The electric appliance connected to the plug is supplied with current.
Normally open (NO) — the plug contacts are open in the normal state. The electric appliance connected to the plug is not supplied with current.

Pulse Duration, sec Indication LED Brightness
Scenarios
Jeweller Signal Strength Test User Guide Permanent Deactivation

Selection of the pulse duration: 1 to 255 seconds.
The setting is available when Socket (type F) operates in the pulse mode.
The option of disabling the LED frame of the device.
The option of adjusting the brightness of the LED frame of the device (max or low).
Opens the menu for creating and configuring automation scenarios.
Scenarios offer a brand-new level of property protection. With them, the security system not only notifies about a threat but also actively resists it.
Use scenarios to automate security. For example, switch on lighting in the facility when an opening detector raises an alarm.
Learn more
Starts Jeweller signal strength test for Socket (type F).
The test allows checking the Jeweller signal strength and the stability of the connection between a hub or a range extender and a smart plug to choose the best place for installing the device.
Learn more
Opens Socket (type F) user manual in the Ajax app.
Allows disable the device without removing it from the system.
Two options are available:
No — the device operates normally, responds to commands, executes scenarios, and transmits all events.

One-Time Deactivation
Delete Device
Indication

Entirely — the device is excluded from the system operation. The smart plug doesn’t respond to commands, doesn’t run scenarios, and doesn’t transmit events.
Socket will retain its state at the time of deactivation: on/off.
Learn more
Allows disabling events of the device until the first disarm.
Two options are available:
No — the device operates in normal mode.
Entirely — the device is completely excluded from system operations until the first disarm. The device does not execute system commands or report alarms and other events.
Socket will retain its state at the time of deactivation: on/off.
Learn more
Disconnects the device from the hub and deletes its settings.

00:00

00:12

Socket (type F) informs the user of the power level consumed by connected appliances using the LED.
If the load is more than 3 kW (purple), the current protection activates.

Load level No power on the Socket (type F) Socket (type F) turned off Socket (type F) turned on, no load ~550 W ~1250 W ~2000 W ~2500 W ~3000 W One or more types of protection triggered Hardware failure

Indication Don’t have any indication Blue Green Yellow Orange Red Dark red Purple Smoothly lights up and goes out red Quick red flashes

The exact power can be seen in the Ajax application.

Functionality Testing
Socket (type F) functionality tests do not begin immediately, but not later than over a single hub ­ smart plug polling period (36 seconds with the Jeweller standard settings). You can change the ping period of devices in the Jeweller menu of the hub settings.
To run a test, in the Ajax app:
1. Select a hub if you have several or use a PRO app. 2. Go to the Devices tab.

3. Select Socket (type F) in the list. 4. Go to Settings . 5. Select and run the Jeweller Signal Strength Test.
Selection of the installation site
When choosing where to install Socket (type F), take into account the Jeweller signal strength and the distance between the device and the hub or the presence of objects that obstruct the radio signal: walls, inter-floor slabs or large structures located at the premises.
Socket (type F) must be installed with a stable Jeweller signal level of 2 to 3 bars.
To roughly calculate the signal strength at the place of installation, use our radio communication range calculator. Use a radio signal range extender if the signal strength is less than 2 bars at the intended installation location.
Do not place Socket (type F):
1. Outdoors. Doing so may cause the device to malfunction or not work correctly.
2. Near metal objects or mirrors (e.g., in a metal cabinet). They can shield and attenuate the radio signal.
3. Inside any premises with the temperature and humidity beyond permissible limits. Doing so may cause the device to malfunction or not work correctly.
4. Close to radio interference sources: less than 1 meter away from the router and power cables. This can cause a loss of connection between a hub or a range extender and the smart plug.
5. In places with low or unstable signal strength. This can cause a loss of connection between a hub or a range extender and the smart plug.
Installation

Before installing the smart plug, make sure that you have selected the optimal location and that it complies with the requirements of this manual.
When installing and operating the device, follow the general electrical safety rules for using electrical appliances and the requirements of electrical safety regulations.
To install Socket (type F):
1. Select the plug into which you want to install the Socket (type F). 2. Plug the Socket (type F) in.
Socket (type F) will turn on within 3 seconds after connection. The device indication will inform you that it is on.
Maintenance
The device does not require maintenance.
Technical specifications

Actuating element Service life

Electromagnetic relay At least 200,000 switches

Voltage and type of external power supply Voltage protection for 230 V mains

110­230 V~, 50/60 Hz Yes, 184­253 V~
We recommend deactivating this protection if the Socket is connected to 110 V~ mains.

Maximum load current Operating modes

11 A (continuous), 13A (up to 5 s)
Pulse and bistable (firmware version is 5.54.1.0 or higher. Manufacture date from March 4, 2020)
Only bistable (firmware version under 5.54.1.0)

Pulse duration
Maximum current protection
Maximum temperature protection Electric shock protection class Energy consumption parameter check Load indicator Output power (resistive load at 230 V) Average energy consumption of the device on standby
Radio communication protocol

1 to 255 seconds (firmware version is 5.54.1.0 or higher) Yes, 11 A if the protection is turned on, up to 13 A if the protection is turned off Yes, +85°. The socket turns off automatically if the temperature is exceeded Class I (with grounding terminal) Yes (current, voltage, power consumption) Yes Up to 2.5 kW
Less than 1 Wh
Jeweller
Learn more

Radio frequency band
Compatibility Maximum radio signal power

866.0 ­ 866.5 MHz 868.0 ­ 868.6 MHz 868.7 ­ 869.2 MHz 905.0 ­ 926.5 MHz 915.85 ­ 926.5 MHz 921.0 ­ 922.0 MHz Depends on the region of sale.
Operates with all Ajax hubs, and radio signal range extenders
8,97 mW (limit 25 mW)

Radio signal modulation Radio signal range Installation method Operating temperature range Operating humidity Protection class Overall dimensions Weight Service life

GFSK Up to 1000 m (when there are no obstacles) In power outlet From 0° to +40° up to 75% IP20 65.5 × 45 × 45 mm (with plug) 58 g 10 years

In case of using inductive or capacitance load, the maximum switched current is reduced to 8 A at 230 V~!
Compliance with standards
Complete Set
1. Socket (type F). 2. Quick start guide.
Warranty
Warranty for the Limited Liability Company “Ajax Systems Manufacturing” products is valid for 2 years after the purchase. If the device does not work correctly, you should first contact the support service–in half of the cases, technical issues can be solved remotely!
The full text of the warranty User Agreement

Customer support: support@ajax.systems

Subscribe to the newsletter about safe life. No spam

Email

Subscribe

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals