cell2 150629M60 6 Inch LED Single Colour Lighthead Instruction Manual

July 30, 2024
Cell2

150629M60
6 Inch LED Single Colour Lighthead

Instruction Manual

Surface Mount

For Synchronisation:
Connect YELLOW wires of all heads together for synchronisation
(All heads should be set at the same Flash Pattern)

For Simultaneous or Alternating Flash:

  1. Apply +VDC to RED and YELLOW wires simultaneously to enter Grouping mode; lighthead will display short (single or double) flashes:
    • Single flash = Group1
    • Double flash = Group2

  2. Remove YELLOW wire from +VDC and momentarily apply to +VDC to change Groups:
    • Heads in the same Group flash together.
    • Group1 Heads alternate with Group2 heads.

For Flash Pattern, momentarily apply +VDC to YELLOW wire:

  • once for next pattern
  • quick three times to reset to FP#1 (see flash pattern chart)

Flash Patterns

1| Double(R65)| 9| Double (SAE)
2| Single(2Hz)| 10| Triple (SAE)
3| Triple(2Hz)| 11| Quad (SAE)
4| Quad(2Hz)| 12| Quint (SAE)
5| Random| 13| Ultra (SAE)
6| Steady| 14| Single-Quad
7| Single(SAE)(CA13)| 15| Single H/L
8| Mega| 16| Singe-Triple-Quint