SHIFT SLC MEK LED 19cm Ceiling Down Light Installation Guide

July 30, 2024
SLC

SHIFT SLC MEK LED 19cm Ceiling Down Light

INSTALLATION GUIDE

SHIFT

WARNING: Only to be installed by an authorized electrician

WARNING: Power off before installing

Surface Mounted

PIR Sensor

Sensor datasheet

Wiering diagram

Detection range diagram

Settings

Detection area:

The detection area can be adjusted by the knob, clockwise adjustment increases the sensitivity, counterclockwise adjustment reduces the sensitivity, the maximum detection distance is 6 meters, the minimum detection distance is 2 meters.

Notice 1: The distance test is carried out under la25°C, 1.8 meters wall mounting installation height. The test result is based on the movement along the tangential direction of the sensor, and the detect distance can be adjusted by the dial switch.

Notice 2: Infrared sensor will be affected by temperature. bo high or too low temperature may affect the detect distance or even cause failure to sensor.

Hold Time:
The hold time can be adjusted by the knob. Clockwise adjustment increases the hold time, counterclockwise adjustment reduces the hold time, the maximum hold time is 7min, and the minimum hold time is 1 OS.
Notice 1: The hold time counting should be started after the sensor is powered on and initialized .

Daylight sensor:

The light threshold can be selected through the Knob. Clockwise adjustment increases the light threshold, counterclockwise adjustment reduces the light threshold, the maximum light threshold is 2000Iux. and the minimum light threshold is 1 Olux. Notice 1 :The light threshold may cause a large deviation in different lamps.

Specifications:

  • Height Clearance to Building Element (HCB): 25mm
  • Minimum Insulation Clearance (MIC): 20mm
  • Side Clearance to Insulation (SCI): 44mm
  • Side Clearance to Auxiliary Equipment (SCB): 25mm

Installation Procedure:

  1. Switch off power before installation.
  2. Switch on only after complete installation and circuit examination.

Caution:

Product modification and improper installation are not covered under warranty. The light source of the luminaire is non-user-replaceable; if damaged, the luminaire must be destroyed to avoid risks.

Risk Warning:

Risk of electric shock and overheating/fire if clearance distances are compromised. Select preferred color and adjust sensor settings accordingly.

Cutout:

Refer to the cutout table for installation requirements.

Sensor Setting:

Please adjust sensor settings according to the installation requirements. Choose the right PIR sensor place as indicated by the label on the luminaire.

Switched Installation:

For switched installation, ensure proper wire stripping length (8-10mm) and follow the wire connection instructions.

THE LIGHT GROUP AS | Tlf.: +47 38 00 21 01 | E-Mail: post@tlg.no
Mjavannsvegen 175 | 4628 | Kristiansand S | Norway

THE LIGHT GROUP GmbH I Phone: +49 511 807 486 10 I E-Mail: info@tlg.no

Am Schafbrinke 62 I 30519 I Hannover I Germany


FAQ:

Q: Can the product be used with any dimmer?

A: No, this product cannot be used with any dimmer. Refer to the dimmer selection table for compatible options.

Q: What is the recommended dimming range?

A: The dimming range is 8-100% when using compatible dimmers.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals