SLC 200-210 Alasvalo Shift Instruction Manual

June 7, 2024
SLC

SLC 200-210 Alasvalo Shift

Product Information

Specifications :

  • Height Clearance to Building Element (HCB): 25mm
  • Side Clearance to Insulation (SCI): 72.5Wmam
  • Side Clearance to Auxiliary Equipment (SCB): 25mm
  • Minimum Insulation Clearance (MIC): 20mm

Product Usage Instructions

Installation Procedure:

  1. Switch off before installation.
  2. Switch on only after complete installation and examination of the circuit.

Installation Spacing:
Ensure the following clearance distances are maintained:

  • HCB: Height clearance to building element = 25mm
  • SCI: Side clearance to insulation = 72.5Wmam
  • SCB: Side clearance to auxiliary equipment = 25mm

Important Notes:
Product modification and improper installation are not valid for warranty. The light source of the luminaire is non-user-replaceable; if damaged, the luminaire should be destroyed to avoid risk

Caution :
Risk of electric shock and overheating/fire if clearance distances are compromised. Please adjust sensor settings according to installation requirements.

FAQ

FAQ – Frequently Asked Questions:

  1. Q: Can the product be used with any dimmer?
    A: No, the product cannot be used with any dimmer. Please refer to the dimmer selection table for compatible dimmers and their  dimming ranges.

  2. Q: How should I choose the right place to install the PIR sensor?
    A: Check the IP label on the luminaire to select the appropriate PIR sensor place for installation.

  3. Q: What is the wire stripping length required for installation?
    A: The wire stripping length should be between 8-10mm for proper installation.

Only to be installed by an authorized electrician

Surface mounted

PIR Sensor

Sensor datasheet

Wiring diagram

Detection range diagram

Settings

  • Detection area: The detection area can be adjusted by the knob, clockwise adjustment increases the sensitivity, counterclockwise adjustment reduces the sensitivity, the maximum detection distance is 6 meters, the minimum detection distance is 2 meters. Notice 1:The distance test is carried out under Ta25°C, 1.8 meters wall mounting installation height. The test result is based on the movement along the tangential direction of the sensor, and the detect distance can be adjusted by the dial switch. Notice 2: Infrared sensor will be affected by temperature. Too high or too low temperature may affect the detect distance or even cause failure to sensor.
  • Hold time: The hold time can be adjusted by the knob. Clockwise adjustment increases the hold time, counterclockwise adjustment reduces the hold time, the maximum hold time is 7 min, and the minimum hold time is 105. Notice 1: The hold time counting should be started after the sensor is powered on and initialized.
  • Daylight sensor : The light threshold can be selected through the Knob. Clockwise adjustment increases the light threshold, counterclockwise adjustment reduces the light threshold, the maximum light threshold is 2000lux, and the minimum light threshold is 10lux. Notice 1: The light threshold may cause a large deviation in different lamps.
  • THE LIGHT GROUP AS
    • Tif.: +47 38 00 21 01
    • E-Mail: post@tig.no Mjavannsvegen 175
    • 4628 Kristiansand S Norway
  • THE LIGHT GROUP GmbH
  • Phone: +49 511 807 486 10
  • E-Mail: info@tig.no Am Schafhrinke 60 | 20510 1 Hannover | Carmany

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals