SALTO WRD Series Glass XS Reader Installation Guide
- July 27, 2024
- SALTO
Table of Contents
Installation guide
Glass XS Reader
Installation guide
x1 x4 x4
Installation
[1]
[2]
[3]
[4]
[5]
The device can be installed in solid walls, such as masonry or concrete, or also in cavity walls using a suitable 60mm built-in mounting box. The mounting box must be mounted level and flush with the wall surface.
Use corresponding mounting holes (1) or (2) depending on the type of box.
[6]
[7]
Electrical characteristics
Operation conditions
| Min.| Max.| Unit
---|---|---|---
Temperature WRDM0M| -30| 70| ⁰C
Humidity| 35| 85| %
RF characteristics
| Min| Cen.| Max.| Unit
---|---|---|---|---
RFID frequency| | 13.56| | Mhz
Bluetooth Smart frequency| 2.4| 2.445| 2.4835| Ghz
Power Consumption Note1
| Min| Max| Unit
---|---|---|---
Reader| | 195| mA
Cable type and max. distances
Cable type | Reader |
---|
UTP Cat5e 2 pairs
AWG24| 213ft
65m
UTP Cat5e 4 pairs AWG24 +
SP224861/SP224895| 656ft
200m
Pares trenzados
AWG18 | 984ft
300m
Note 1: Installer must take this data into account to dimension the CU42xx
power supply.
Glass XS Reader only for use with the SALTO Control Units.
SALTO recommends to use one cable per wall reader.
Installation example
Installation example CU42xx:
B | Green |
---|---|
A | White |
Black | |
+V | Red |
- Same pair
- Cable connection
Installation example CU41xY:
Control Unit CU41xY
- Same pair
Installation example CUCxx:
Installation example with RJ45
Installation example CU42xx with RJ45xx:
- Optional SP224861
- Optional SP224895
- Black
- Red
Minimum distance between readers 20in (50cm).
Installation example CU41xY with RJ45xx:
Control Unit CU41xY
- Optional SP224861
- Optional SP224895
- Red
European view
All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any item in
this catalog, its design, construction, and/or materials.
© 2023 SALTO Systems S.L.