Teleflex PB-50014-100B One Lumen CVC Instructions
- July 26, 2024
- Teleflex
Table of Contents
PB-50014-100B One Lumen CVC
“`html
Specifications:
-
Dimensions: Width: 6-9/64 (15.6 cm), Length: 8-21/32 (22
cm) -
Model Numbers: PB-50014-100B, PBZ-50014-103A
-
Product of: xxx, Packaged in: xxx
-
Product Code: T50014100A6, Dimensions: 5 7/8 x 7 5/8
-
CS Code: CS-04306-EJ (IPNXXXXXX)
-
Type: One-Lumen CVC
Product Usage Instructions:
Contents:
- 1 One-Lumen Catheter: 16 Ga. (1.8 mm OD) x 16 cm
- 1 Spring-Wire Guide, Marked: .032 (0.81 mm) dia. x 17-3/4 (45
cm) (Straight Soft Tip on One Lumen Distal (16 Ga.)
Warnings:
Read all package insert warnings, precautions, and instructions
prior to use. Failure to do so may result in severe patient injury
or death. Visit www.teleflex.com/IFU
Priming Volume & Flow Rate:
-
Priming Volume*: 0.4 mL
-
Gravity Flow Rate: 3013 mL/hr
-
Priming volumes are approximate and are done without
accessories. Flow rate values are approximate and are determined
using deionized water at 100 cm head height.
Manufacturer Information:
CAS # 7440-48-4
EU Authorized Representative and Importer: Teleflex Medical IDA
Business and Technology Park Dublin Road, Athlone Co. Westmeath,
Ireland
Arrow International LLC Subsidiary of Teleflex Incorporated,
3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
Lot Information:
Lot Number: YYYY-MM-DD
FAQ:
Q: Is the product made with natural rubber latex?
A: No, the product is not made with natural rubber latex.
Q: What is the length of the catheter included in the
package?
A: The catheter included is 16 cm in length.
“`
Dimensions: Width: 6-9/64″ (15,6 cm) Length: 8-21/32″ (22 cm)
PB-50014-100B PBZ-50014-103A
Product of xxx Packaged in xxx
T50014100A6 Dimensions: 5 7/8″ x 7 5/8″
CS-04306-EJ (IPNXXXXXX)
One-Lumen CVC
Contents:
1: One-Lumen Catheter: 16 Ga. (1.8 mm OD) x 16 cm 1: Spring-Wire Guide,
Marked: .032″ (0.81 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One
End – “J” Tip on Other) with Arrow Advancer 1: Catheter: 18 Ga. x 2-1/2″ (6.35
cm) Radiopaque over 20 Ga. RW Introducer Needle 1: Introducer Needle: 18 Ga. x
2-1/2″ (6.35 cm) XTW 1: Pressure Transduction Probe 1: Arrow® Raulerson
Spring-Wire Introduction Syringe: 5 mL 1: Tissue Dilator: 7 Fr. (2.3 mm) x
10.2 cm 1: Dust Cap: Non-Vented 1: SecondSiteTM Adjustable Hub: Fastener 1:
SecondSiteTM Adjustable Hub: Catheter Clamp All components are CE 2797 unless
otherwise noted.
Warning: Read all package insert warnings, precautions, and instructions prior
to use. Failure to do so may result in severe patient injury or death.
www.teleflex.com/IFU Not made with natural rubber latex. Fluid path components
are non-pyrogenic.
Lumen Distal (16 Ga.)
Priming Volume*
(mL) 0.4
Gravity Flow Rate
(mL/hr) 3013
- Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height.
CAS # 7440-48-4
EU Authorized Representative and Importer:
Teleflex Medical IDA Business and Technology Park Dublin Road, Athlone Co.
Westmeath, Ireland
Arrow International LLC Subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
LotNumber YYYY-MM-DD
YYYY-MM-DD
LBL074417 R00 (2024-02)
(01)XXXXXXXXXXXXXX (17)YYMMDD (11)YYMMDD (10)LotNumber
CS-04306-EJ
16 1 Ga.
Lumen
16 cm catheter length
.032 inch dia. spring-wire guide
One-Lumen CVC
References