IMPORTANT SAFETY INSTRUCTIONS

Please read the User Guide carefully before installation.

IMPORTANT SYMBOLS

WARNING
Indicates potentially dangerous conditions that could result in personal injury

CAUTION
Indicates conditions or practices that could result in damages to the unit or other equipment

NOTE
Indicates procedures or functions that are important for proper and safe operation of the unit and/or other equipment

WARNING

  • DO NOT disassemble the unit or remove any attached components. Incorrect reassembly may result in a risk of fire or electric shock.
  • WARNING Keep the unit out of reach of children unless supervised by an adult.
  • DO NOT operate the unit if it has been smashed, squashed, pierced, or otherwise damaged in anyway.
  • The unit is only compatible with 12V lead-acid batteries. DO NOT connect it to other types of batteries or batteries with nominal voltages other than 12V. Doing so may cause irreversible damages to the unit and/or battery explosion.
  • To reduce the risk of a battery explosion, please follow the instructions published by the battery manufacturer and review the cautionary markings on the battery carefully
  • DO NOT place the unit on a surface constructed from combustible material.
    Keep the unit away from explosives and corrosive substances.

CAUTION

  • The unit is designed to withstand splashes and spills but is not fully waterproof. DO NOT submerge the unit in water or leave it in the rain.
  • Dispose of the unit according to the local recycling and environmental regulations.
  • DO NOT step, walk, stand, or jump on the unit. Localized heavy loads may cause variances of micro-cracks on the solar cells, which will ultimately compromise the reliability of the unit.

NOTE
Clean the surface of the solar battery charger maintainer as necessary for optimal performance.

PACKAGE CONTENTS

  • 1 x Renogy 5W Solar Battery Charger Maintainer
  • 1 x SAE to Ring Terminal Cable
  • 1 x SAE to Alligator Clip Cable
  • 1 x SAE to Cigarette Lighter Plug Cable
  • 8 x Suction Cups
  • 1 x User Guide

SPECIFICATIONS

Solar Panel


Rated Maximum Power|

5W

Open Circuit Voltage

| 21.6V
Short Circuit Current|

0.3A

Optimum Operating Voltage

| 18V
Optimum Operating Current|

0.27A

Operating Temperature Range

| -4~140    / -20~60
Output Connector|

SAE

Dimension

| 7.9 x 9.8 x 0.1 inch / 200 x 250 x 3 mm
Weight|

10.5 oz / 298 g

MPPT Charge Controller

Boost Voltage|

14.8V

Float Voltage

| 13.55V
Maximum Input Current|

0.35A

Maximum Output Current

| 0.4A
Operating Temperature Range|

-4~185    / -20~85

INSTALLATION

WARNING

  • DO NOT leave the solar battery charger maintainer connected and unattended for extended periods of time. Check the battery status frequently for safe operation.
  • Place the solar battery charger maintainer as far away from the battery as the adapter cables permit. DO NOT place it directly above the battery.

CAUTION
The solar battery charger maintainer MUST be disconnected from the battery or cigarette lighter port when starting the engine or driving the vehicle. Electric surges from the alternator when starting and running may damage the solar battery charger maintainer.

NOTE
The solar battery charger maintainer is designed to compensate for the battery self-discharge. Please do not rely on it for a full charge.
INSTALLATION
INSTALLATION
INSTALLATION

CONNECTING DIRECTLY TO THE BATTERY

  • Check the polarity of the battery terminals. The positive (POS, P, +) terminal usually has a larger diameter than the negative (NEG, N, -) terminal. – 05 – – 06 –

  • Connect the included SAE to Ring Terminal Cable or SAE to Alligator Clip Cable to the battery.

  • If the battery is installed in the vehicle, the vehicle ground type must be identified. For a negative-grounded vehicle, first connect the positive (red) alligator clip or ring terminal to the positive (POS, P, +) terminal of the battery, and then connect the negative (black) alligator clip or ring terminal to the vehicle chassis or engine block away from the battery.
    For a positive-ground vehicle, first connect the negative (black) alligator clip or ring terminal to the negative (NEG, N, -) terminal of the battery, and then connect the positive (red) clip to the vehicle chassis or engine block away from the battery.

  • If the battery is outside the vehicle, a 24 inch (610mm) 6 AWG (13 mm2) insulated battery cable must be first connected to the negative (NEG, N, -) battery terminal. Then connect the positive (red) alligator clip or ring terminal to the positive (POS, P, +) terminal of the battery and connect the negative (black) alligator clip or ring terminal to the free end of the battery cable away from the battery.

  • Connect the SAE to Ring Terminal Cable or SAE to Alligator Clip Cable to the solar battery charger maintainer.

  • Place the solar battery charger maintainer, facing due south (or north), in the path of the sun. Make sure that no shadows are cast on the solar battery charger maintainer.

WARNING

  • Electric shock can occur if the adapter cable is damaged. DO NOT use a damaged adapter cable to maintain or charge the battery. Position the adapter cable properly to reduce the risk of damage by the hood, door, or hot engine parts.
  • If it is necessary to close the hood during the maintaining or charging process, ensure that the hood does not touch the metal part of the alligator clips or ring terminals, or cut the insulation of the adapter cable.
  • Stay clear of fan blades, belts, pulleys, and other parts that can cause injury.
  • NEVER allow the alligator clips or ring terminals to touch each other.
  • When disconnecting the solar battery charger maintainer, please follow the above procedures in reverse order.
  • DO NOT connect the alligator clips or ring terminals to the carburetor, fuel lines, or sheet-metal body part.

CONNECTING TO THE CIGARETTE LIGHTER PORT

  • Park the vehicle in direct sunlight with the front facing due south (or north).
  • Connect the solar battery charger maintainer to the included SAE to Cigarette Lighter Plug Cable.
  • Insert the cigarette lighter plug into the cigarette lighter port.
  • Attach the solar battery charger maintainer to the windshield using included Suction Cups.

NOTE
For some makes or models of vehicles, the cigarette lighter port may not operate when the ignition is turned off. In such cases, please connect the solar battery charger maintainer to the battery directly.

INTELLIGENT CHARGING TECHNOLOGY

The built-in charge controller employs a 3-stage charging algorithm for an efficient and safe charging process, which includes bulk charge, boost charge, and float charge.

  • Bulk Charge: During this stage, the built-in charge controller utilizes the MPPT (Maximum Power Point Tracking) algorithm to automatically track the maximum power point voltage of the solar panel and charges the battery at a constant maximum current until the battery voltage increases to the boost voltage.
  • Boost Charge: During this stage, the built-in charge controller keeps the battery at the boost voltage while gradually decreasing the charging current. The Boost Charge stage helps the battery retain the energy stored during the Bulk Charge stage.
  • Float Charge: During this stage, the built-in charge controller charges the battery at the float voltage with a small maintenance current, making up for the loss of battery self-discharge. The Float Charge stage keeps the battery topped off once it is fully charged.
    INTELLIGENT CHARGING TECHNOLOGY

WARRANTY

  • RENOGY products are covered by a 1-year limited warranty from the original purchase date. If any problems occur, please contact us for assistance. Refer to the last page of User Guide for contact information.
  • We only provide after-sales services for products that are sold by RENOGY or retailers and distributors authorized by RENOGY. If you have purchased your unit from other channels, please contact your seller for more information about return and warranty.
  • Please register your purchase(s) directly at www.renogy.com/warranty-registration or your region’s corresponding website so that we can stay in touch and contact you in the unlikely event that a safety recall is required.

FCC Compliance

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must withstand any interference received, including interference that may cause undesired operation.

US
2775 E Philadelphia St, Ontario, CA 91761, USA
909-287-7111
www.renogy.com
 support@renogy.com

CN
苏州高新区科技城培源路1号5号楼-4
400-6636-695
https://www.renogy.cn
**** support@renogy.cn

JP
https://www.renogy.jp
supportjp@renogy.com

CA
https://ca.renogy.com
supportca@renogy.com

AU
https://au.renogy.com
supportau@renogy.com

UK
https://uk.renogy.com
supportuk@renogy.com

DE
https://de.renogy.com
supportde@renogy.com

Company Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals