Teleflex CDC-45703-XPB1A Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC Instruction Manual
- June 4, 2024
- Teleflex
Table of Contents
Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC
Instruction Manual
CDC-45703-XPB1A Pressure Injectable Arrowg+ard Blue Plus Three-Lumen CVC
CDC-45703-XPB1A
7Fr,20cmcatheter length,025inchdia.spring-wire guide.
1:Arrowg+ardBluePlus®1Three-
LumenCatheter:7Fr.(2.5mmOD)x20cm,PressureInjectable
1:Spring-
WireGuide,Marked:.025″(0.64mm)dia.x23-5/8″(60cm)(StraightSoftTiponOneEnd-“J”TiponOther)withArrowAdvancer
1:Catheter:20Ga.x1-3/4″(4.45cm)Radiopaqueover22Ga.TWIntroducerNeedle
1:IntroducerNeedle:Echogenic18Ga.x2-1/2″(6.35cm)RW
1:InjectionNeedle:SafetyGlide™225Ga.x1″(2.54cm)
1:BluntFillNeedle:18Ga.x1-1/2″(3.81cm)
1:PressureTransductionProbe
1:IntroducerNeedle:Echogenic20Ga.x1-1/2″(3.81cm)XTWand5mLArrow
®RaulersonSpring-WireIntroductionSyringe
1:InjectionNeedle:SafetyGlide™222Ga.x1-1/2″(3.81cm)and5mLLuer-SlipSyringe
1:Syringe:3mLLuer-Lock
1:TissueDilator:8.5Fr.(2.8mm)x10.2cm2:10mLLuer-LockPre-FilledSalineSyringe
1:5mL1%LidocaineHClSolutionandAlcoholPrep1:3mLApplicator2%CHGand70%IPAChloraPrep
®3One-StepSolutionwithHi-LiteOrange™Tint
1:SecondSite™AdjustableHub:Fastener.
1:SecondSite™AdjustableHub:CatheterClamp
1:SharpsAway®DisposalCup1:SharpsAway®IILockingDisposalCup
1:MaximalBarrierDrape™with4″fenestration
1:Towel
1:NeedleHolder
1:SafetyScalpel:#11
1:Checklist/CLIPSheet
1:FlowRateInformationCardwithInjectionLog
1:SterileProcedureSign
1:MedicationLabel:1%Lidocaine2:GauzePad:2″x2″(5cmx5cm)5:GauzePad:4″x4″(10cmx10cm)
1:Dressing:Tegaderm®410cmx12cm
1:SurgicalApparel: ImperviousGown
1:Dressing: BIOPATCH®5
1:SurgicalApparel:BouffantCap
1:SurgicalAppare
l: MaskwithEyeShield
1:Suture:3-0SilkwithCurvedNeedle
1:Tubing±:20″(50cm)Extension
1:HemoHopper®FluidReceptacle
- Licensed under USPatentNo.7,329,412.
- A trademark of Becton, Dickinson, and company.
- A registered trademark of Care Fusionoroneo fits sub-subsidiaries.
- A registered trademark of3M Company.
- A registered trademark of Johnson & Johnson Corporation.
±Precaution: Contains Phthalate: DEHP.
Warning: The results of certain animal experiments have shown phthalates
to be potentially toxic to reproduction. Proceeding from the present state of
scientific knowledge, risks for male premature infants cannot be excluded in
the case of long-term exposure or application. Medical products containing
phthalates should be used only temporarily with pregnant women, nursing
mothers, babies, and infants.
Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F).
Arrow International provides the enclosed medication label(s) for your
convenience. Please ensure that these labels are applied to the correct
syringe and corresponding medication.
Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is
contraindicated for patients with known hypersensitivity to chlorhexidine,
silver sulfadiazine and/or sulfa drugs.
Priming Volume* (mL)
Gravity Flow Rate (mL/hr)
MAX Pressure Injection Flow Rate** (mL/sec)
Distal (16 Ga.) 0.39 2283 10 Medial (18 Ga.) 0.39 913 5 Proximal (18 Ga.) 0.40
996 5
Lumen| *Priming Volume (mL )| Gravity Flow Rate† (mL/hr)|
MAX Pressure Injection Flow Rate (mL/sec)
---|---|---|---
Distal(16Ga.)| 0.39| 2283| 10
Medial(18Ga.)| 0.39| 913| 5
Proximal(18Ga| 0.4| 996| 5
-
Priming volumes are approximate and are done without accessories.
t Flow rate values are approximate and are determined using deionized water at 100 cm head height. -
Pressure injection flow rates are determined using media of 11.8 centipoises (cP) viscosity, with 152 cm administration set tubing.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>