Teleflex EU-25052-HPMSB Pressure Injectable Two-Lumen PICC Instruction Manual
- June 3, 2024
- Teleflex
Table of Contents
Teleflex EU-25052-HPMSB Pressure Injectable Two-Lumen PICC Instruction
Manual
Contents
-
1: Two Lumen Catheter: 5 Fr. (1.81 mm OD) x 50 cm, Pressure Injectable, T-Port
Connector, Blue FlexTip®, Contamination Guard and Placement Wire -
1: GlideThru™ Peel-Away Sheath: 5 Fr. x 2-3/4″ (7 cm) Radiopaque over 5 Fr. Dilator
-
1: Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm)
(Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer -
1: Injection Needle: Eclipse™1 22 Ga. x 1-5/8″ (4 cm)
-
1: Injection Needle: Eclipse™1 25 Ga. x 1″ (2.54 cm) RW
-
1: Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
-
1: Filter Needle: 18 Ga. TW x 1-1/2″ (3.81 cm) with Blunt Fill Tip 2: Syringe: 10 mL Luer-Lock
-
1: Syringe: 3 mL Luer-Lock
-
1: SecondSite™ Adjustable Hub: Fastener
-
1: SecondSite™ Adjustable Hub: Catheter Clamp
-
1: SharpsAway® Disposal Cup
-
1: SharpsAway® II Locking Disposal Cup
-
1: Catheter Trimmer
-
1: Towel: 24″ x 36″ (61 cm x 91 cm)
-
1: Drape: 60″ x 76″ (152 cm x 193 cm)
-
1: Drape: 36″ x 41″ (91 cm x 104 cm) with 3″ x 5″ (8 cm x 13 cm) fenestration
-
1: Towel
-
1: Safety Scalpel: #11
-
1: Patient ID Card
-
1: Sterile Procedure Sign
-
1: Patient Information Booklet
-
1: Chart Sticker
-
1: PICC Line Insertion Checklist
-
1: Paper Tape Measure
-
1: Tourniquet 5: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
-
1: Dressing: Tegaderm®2 I.V. 4″ x 6″ (10 cm x 15.5 cm)
-
1: Dressing: GRIP-LOK®3 Catheter Fixation Device 10: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
-
1: Surgical Apparel: Cap
-
1: Surgical Apparel: Impervious Gown
-
1: Dressing: Steri-Strip®2 1/2″ x 4″ (1.2 cm x 10 cm)
-
1: Surgical Apparel: Mask 1: Surgical Apparel: Mask with Shield
-
1: Transducer Cover: 4-12/16″ x 95″ (12 cm x 244 cm) 2: Valve: MicroCLAVE®4 Neutral Displacement Connector
-
1: Hemo Hopper® Fluid Receptacle
-
1A trademark of Becton, Dickinson and Company
-
2A registered trademark of 3M Company.
-
3A registered trademark of TIDI.
-
4A registered trademark of ICU Medical, Inc.
All components are CE 2797 unless otherwise noted.
Warning: Read all package insert warnings, precautions, and instructions
prior to use. Failure to do so may result in severe patient injury or death.
www.teleflex.com/IFU
Not made with natural rubber latex.
Fluid path components are non-pyrogenic.
Contraindications: The Pressure Injectable PICC is contraindicated wherever
there is presence of device related infections or presence of thrombosis in
the intended insertion vessel or catheter pathway. Clinical assessment of the
patient must be completed to ensure no contraindications exist.
Lumen
| *Priming Volume (mL)| Gravity Flow Rate† (mL/hr| Pump Flow
Rate†† (mL/hr)| MAX Pressure Injection Flow Rate (mL/sec)
---|---|---|---|---
Distal (18 Ga.) Proximal (18 Ga.)| 0.4 0.43| 356
396| 3106
3490| 4
4
Priming volumes are approximate and are done without accessories.
† Flow rate values are approximate and are determined using deionized water at
100 cm head height.
†† Pump flow rates are determined at maximum pump pressure of 10 psig and
represent approximate flow capabilities.
Pressure injection flow rates are determined at the injector pressure setting
of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm
pressure tubing.
Features
Pressure Injectable Two-Lumen PIC
EU-25052-HPMSB
Support
EU Authorized Representative and Importer
Teleflex Medical IDA Business and
Technology Park Dublin Road, Athlone Co. Westmeath, Ireland
Arrow International LLC
Subsidiary of Teleflex Incorporated
3015 Carrington Mill Blvd. Morrisville, NC 27560 USA
LBL056531 R00 (2021-06)
www.teleflex.com
References
Read User Manual Online (PDF format)