Contents

  • 1: Two Lumen TaperFree® Catheter with Arrowg+ard Blue Advance® Antimicrobial/Antithrombogenic Protection1: 5.5 Fr. (1.88 mm OD) x 55 cm, Pressure Injectable, Blue FlexTip®, Arrow® VPS Precision™ Stylet, Tuohy- Borst Adapter, Marking Device, and Console Pointers
  • 1: GlideThru™ Peel-Away Sheath: 5.5 Fr. x 2-3/4″ (7 cm) Radiopaque over 5.5 Fr. Dilator
  • 1: Spring-Wire Guide, Nitinol, Marked: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on One End – Straight Stiff Tip on Other) with Arrow Advancer
  • 1: Injection Needle: SafetyGlide™2 25 Ga. x 5/8″ (1.60 cm) RW
  • 1: Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  • 1: Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  • 1: Syringe: 10 mL Luer-Lock
  • 1: Syringe: 3 mL Luer-Lock
  • 1: Skin Protectant Prep
  • 2: Dust Cap: Non-Vented
  • 1: SecondSite™ Adjustable Hub: Fastener
  • 1: SecondSite™ Adjustable Hub: Catheter Clamp
  • 1: SharpsAway® Disposal Cup
  • 1: SharpsAway® II Locking Disposal Cup
  • 1: Catheter Trimmer
  • 1: Towel: 24″ x 36″ (61 cm x 91 cm)
  • 1: Maximal Barrier Drape™ with two 13 cm (5″) x 15 cm (6″) fenestrations
  • 1: Safety Scalpel: #11
  • 1: Sterile Procedure Sign
  • 1: Patient ID Card
  • 1: Chart Sticker
  • 1: Patient Information Booklet
  • 1: Checklist/CLIP Sheet
  • 2: Paper Tape Measure
  • 1: Tourniquet
  • 1: Foam Electrodes (3 per pack)
  • 10: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
  • 10: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
  • 1: Dressing: Tegaderm®3 15.5 cm x 10 cm
  • 1: Surgical Apparel: Impervious Gown
  • 1: Dressing: STATLOCK®4 Catheter Stabilization Device
  • 1: Surgical Apparel: Mask with Eye Shield
  • 1: Surgical Apparel: Bouffant Cap
  • 1: Surgical Apparel: Mask
  • 1: Surgical Tape: Transpore™5 1″ x 54″ Roll
  • 1: HemoHopper® Fluid Receptacle
  • 1Licensed under US Patent No. 7,329,412.
  • 2A trademark of Becton, Dickinson and Company.
  • 3A registered trademark of 3M Company.
  • 4A registered trademark of C. R. Bard, Inc.
  • 5A trademark of 3M Company.

Not made with natural rubber latex.
Store below 25°C (77°F). Avoid excessive heat above 30°C (86°F).
Contraindications: The Pressure Injectable Arrowy+ard Blue Advance antimicrobial/antithrombogenic catheter is contraindicated:

  • for patients with known hypersensitivity to chlorhexidine
  • in the presence of device related infection in the intended insertion vessel or catheter pathway
  • in the presence of thrombosis in the intended insertion vessel or catheter pathway

Teleflex-Pressure-Injectable-Arrowg+Ard-Blue-Advance-Two-Lumen-PICC-Pre-
Loaded-1

Priming volumes are approximate and are done without accessories.
Flow rate values are approximate and are determined using deionized water at 100 cm head height.
Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities.
Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.