COMELIT VEDO68 Box Plastico Alim Instructions
- July 27, 2024
- Comelit
Table of Contents
Vedo
VEDOGSM4G
TECHNICAL MANUAL https://pro.comelitgroup.com/manuals/19274
4G module for VEDO control panels
VEDOGSM4G allows the sending of telephone calls, SMS, MMS and emails over the data network, as well as the sending of digital protocols and date/ time synchronisation. Used in conjunction with the VEDOVOICE voice message board, it allows remote management of the control panel by a voice dialler. The module also allows connection from the Comelit app.
Main features
-
EGSM900, DCS1800, WCDMA B1/B8, LTE FDD B1/B3/B7/B8/B20/B28
-
GSM/GPRS/UMTS/USPA/LTE channel support
-
Antennas included:
– main antenna for connection to ANT1
– secondary antenna (diversity) for connection to ANT2 in the event of a weak signal -
Main or reserve telephone dialler
-
Indication of alarms/malfunctions/sabotage/events via SMS
-
Customisable SMS messages
-
Control panel status interrogation via SMS
-
Checking residual credit of the prepaid SIM
-
Transmission of Voice Messages via GSM
-
Event transmission in Contact-ID and SIA (Level 1) format via GSM and over TCP-IP (SIA-DC-09 protocol support)
-
Event transmission by email with images
-
Event transmission by MMS
-
Date and time updating
Compatibility
VEDOGSM4G can only be used with Comelit control panels VEDO10, VEDO34,
VEDO34M, VEDO68, VEDO68M, VEDO200, VEDO200M, fi rmware version ≥2.12.4
Technical specifications
Name of manufacturer / supplier | Comelit Group S.p.A. |
---|---|
Dimensions (w x h x d) | 72 x 48 x 29 mm (without antenna) |
Weight | 30 g without antenna 46 g with 1 antenna |
Consumption (min./max.) | 36 mA in Idle, 80 mA when communicating |
Average power consumption in 1 h: VEDOGSM4G: 43 mAh 1 alarm every 5 minutes
and communication with duration of 1 minute
Operating temperature and Operating humidity| -10 °C /+ 55 °C with warm
dry air -10 °C / + 40 °C with max. + 93% RH (not condensed)
Interface type| Control panel expansion
Operating mode saving and forwarding event /
event transmission| event transmission (pass-through)
Generation and/ or transmission times of alarm
messages| voice messages: 10 sec email: 10 sec without image 90 sec with
image MMS: 45 sec
limes for generating a reply signal (when used)| CONTACT ID: times
according to standard SIA DC-05-1999.09 SIA: times according to standard SIA-
DC-03-1990.01 SIA-DC-09: times according to standard ANSI/SIA-DC-09-2007
Times for detect- ing and present- ing faults| No GSM and GPRS
coverage: 120 sec
SIM fault: 20 sec
Antenna disconnected: 45 sec
---|---
Method for signalling faults to alarm system| Alert send
failure: regular or on event
Level of output signals and/or sensitivity of input signals|
Minimum level DTMF tones at input: 36mVeff – 28.8dbV 100mVpp Level DTMF tones
at output: low freq 9 dBm / high freq 11 dBm
Safety signals level supplied| ATS2-10 no information protection
ATS2-S0 protection against substitution
Sharing of trans- mission connections| EGSM900, DCS1800, WCDMA
B1/B8, LTE FDD B1/B3/B7/B8/ B20/B28
Class 4 (33 dBm ± 2 dB) for EGSM900
Class 1 (30 dBm ± 2 dB) for DCS1800
Class E2 (27 dBm ± 3 dB) for EGSM900 8-PSK
Class E2 (26 dBm ± 3 dB) for DCS1800 8-PSK
Class 3 (24 dBm +1/-3 dB) for WCDMA bands
Class 3 (23 dBm ± 2 dB) for LTEFDD bands
Voltage operating range| 10∼ 15 V
Description
- Antenna connector ANT1
- Antenna connector ANT2
- Holes for securing the module to the control panel board
- Module connector position
- LED indicators: D1 (top), D3 (middle), D2 (bottom)
- LED enabling/disabling jumper
- Micro-SIM slot
MEANING OF THE LEDS
D1
RED| Off: Module not working
Flashing quickly (64 ms On/ 800 ms Off):
Module not connected to the network
Flashing slowly (64 ms On/ 2000 ms Off):
Module connected to the network
---|---
D3
ORANGE| Module serial communication. Lights up briefly when the module
communicates with the control panel.
D2
GREEN| Module serial communication. Lights up briefly when the module
communicates with the control panel.
CONFIGURATION JUMPERS
LED | If disconnected, the LEDs switch off |
---|---|
DBG | Reserved |
RSDV | Reserved |
CSL | Reserved |
Installation
Cut off the power supply (both power supply unit and battery) before fitting/removing modules! Risk of permanently damaging the expansion module and the control panel board.
-
Make sure the board on which you intend to fit the module is not connected to the power supply!
-
Insert the plastic spacers in the relevant holes.
-
Then, taking care to plug the module connector into the control panel connector designated MOD5 correctly, apply sufficient pressure to engage the spacers in the GSM expansion card and plug the connector in almost completely.
For the module to work, at least one of the two antennas must be connected and fastened to connector ANT1. -
Fasten the cable connector onto the goldcoloured ANT1 connector on the VEDOGSM4G module.
Connecting the second antenna improves performance in weak signal conditions. -
If using the second antenna, proceed by fastening the cable to the gold-coloured connector ANT2 on the VEDOGSM4G module.
It is important that each antenna is connected correctly and tightened fully.
The antennas must be positioned perpendicular to one another!
Antenna presence can only be detected using the antennas supplied. In all
other cases antenna presence detection must be excluded from the GSM dialler
options.
ANTENNA POSITIONING IN BOXSTANDARD HOUSING
Antennas can be fitted externally; for this reason there are 2 cutouts to
allow easy feedthrough of the antenna cables.
- The antennas must be positioned perpendicular to one another!
- Do not place the antenna on metal surfaces!
- Place the antenna at least 20 cm away from the VEDOGSM4G module.
ANTENNA POSITIONING WITH BOXMETAL HOUSING
Position the antennas outside the housing using the specific antenna outlet.
- The antennas must be positioned perpendicular to one another!
- Do not place the antenna on metal surfaces!
FITTING THE SIM CARD
- Make sure the board on which you intend to fit the module is not connected to the power supply!
√ The SIM card must be enabled, and if it is a payas-you-go type, it must have sufficient credit on it to be able to make phone calls, send messages or transmit digital protocols via TCP-IP.
It is not essential to unlock it, because the control panel is capable of managing the PIN to unlock the SIM card.
Before using the module, it must be enabled with the Safe Manager software.
If the module is enabled but not connected, a fault will be generated.
Warning
- This Comelit product has been designed and manufactured for use in the creation of security and automation systems in residential, commercial, industrial and public buildings.
- All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the indications provided in the manuals supplied with those products. The product must be installed to the highest standards.
- Disconnect the power supply before carrying out any operations on the wiring.
- Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
- We advise against running the system wires through the same duct as power cables (230V or higher).
- To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets; make sure the system created using Comelit products has not been tampered with / damaged.
- Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in the manuals / instruction sheets. Any repairs must be carried out: for the products themselves, exclusively by Comelit Group S.p.A.; for the systems, by qualified technical personnel. Do not use alcohol or aggressive products for cleaning purposes.
- Comelit Group S.p.A. accepts no liability for any purpose other than the intended use, or failure to observe the indications and warnings contained in this manual / instruction sheet. Comelit Group S.p.A. reserves the right to change the information provided in this manual / instruction sheet at any time and without prior notice.
- The manufacturer, Comelit Group S.p.A., hereby declares that this equipment conforms to the applicable directives. The full EU conformity declaration is available on the product web page.
- In accordance with art. 26 of Italian Legislative Decree dated 14th March 2014, no. 49 “Implementation of directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE)”, the “crossed-out wheelie bin” symbol indicates that at the end of its useful life, this product must be separated from other waste before collection for disposal. The user should therefore take the exhausted appliance to suitable local collection centres for waste electrical and electronic products. As an alternative to handling this process yourself, you can take the appliance to your local equipment dealer when purchasing a new equivalent product. Electronics dealership businesses covering an area of 400 m² are also obliged to accept waste electronic products smaller than 25 cm for disposal, without any obligation to purchase. Suitable separated waste collection for the subsequent reuse of the appliance sent for recycling, processing and environmentally conscious disposal helps to avoid potential negative effects on the environment and human health, and encourages the reuse and recycling of the materials used in the construction of the appliance.
www.comelitgroup.com
Via Don Arrigoni, 5 – 24020 Rovetta (BG) – Italy 2ª edizione 01/2024 cod.
2G40003215
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>