PEDROLLO 50Hz F Centrifugal Pumps Standardized According to EN733 User Guide
- July 18, 2024
- pedrollo
Table of Contents
- 50Hz F Centrifugal Pumps Standardized According to EN733
- PERFORMANCE RANGE
- INSTALLATION AND USE
- ELECTRIC MOTOR
- APPLICATION LIMITS
- AVAILABLE UPON REQUEST
- CURVES AND PERFORMANCE DATA
- ABSORPTION
- MATERIALS AND COMPONENTS
- Technical data
- DIMENSIONS AND WEIGHT
- PORT FLANGES
- COUNTER-FLANGE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
F Centrifugal pumps standardized according to EN733
50 Hz
50Hz F Centrifugal Pumps Standardized According to EN733
| Clean water
---|---
| Civil use
| Industrial use
PERFORMANCE RANGE
• Flow rate up to 5750 l/min (345 m3/h)
• Head up to 98 m
• Power from 1.5 to 75 kW
INSTALLATION AND USE
Close-coupled centrifugal electric pumps with flanges constructed according to the EN733 standard.
- For clean water free from abrasive particles and liquids that will not damage the pump’s components
- Water supply
- Pressurization
- Irrigation
- Water circulation in air conditioning systems
- Power washing systems
- Firefighting systems
- Industrial applications
- Agriculture applications
Installation should be carried out in well-ventilated indoor or protected areas.
ELECTRIC MOTOR
The three-phase pumps are equipped with newly developed electric motors
designed to work with inverters, which guarantee stable and quiet operation.
Efficiency class IE3 for three-phacse motors, IE2 for single-phase motors,
class F insulation and IP55 protection.
APPLICATION LIMITS
- Manometric suction head up to 7 m
- Liquid temperature between -10 °C and +90 °C
- Ambient temperature between -10 °C and +40 °C
- Maximum pressure in the pump body 10 bar (PN10)
AVAILABLE UPON REQUEST
※ Mechanical seal options available
※ Different voltage requirements 60 Hz frequency
※ Handling of liquids with higher or lower temperatures
※ Adaptability to operate in high or low temperature environments
※ Counterflange KIT including screws, nuts and gasketsg PERFORMANCE RANGE –
n= 2900 min-1
50 Hz![PEDROLLO 50Hz F Centrifugal Pumps Standardized According to EN733
- PERFORMANCE RANGE](https://manuals.plus/wp-content/uploads/2024/07/PEDROLLO- 50Hz-F-Centrifugal-Pumps-Standardized-According-to-EN733-PERFORMANCE- RANGE.jpg)
PERFORMANCE DATA – n= 2900 min-1
TYPE | POWER (P2) | PERFORMANCE |
---|---|---|
kW | HP | Q l/min |
F 32/160C | 1.5 | 2 |
F 32/160B | 2.2 | 3 |
F 32/160A | 3 | 4 |
F 32/200C | 4 | 5.5 |
F 32/200B | 5.5 | 7.5 |
F 32/200A | 7.5 | 10 |
F 32/200BH | 3 | 4 |
F 32/200AH | 4 | 5.5 |
F 32/250C | 9.2 | 12.5 |
F 32/250B | 11 | 15 |
F 32/250A | 15 | 20 |
F 40/125C | 1.1 | 1.5 |
F 40/125B | 1.5 | 2 |
F 40/125A | 2.2 | 3 |
F 40/160C | 2.2 | 3 |
F 40/160B | 3 | 4 |
F 40/160A | 4 | 5.5 |
F 40/200B | 5.5 | 7.5 |
F 40/200A | 7.5 | 10 |
F 40/250C | 9.2 | 12.5 |
F 40/250B | 11 | 15 |
F 40/250A | 15 | 20 |
F 50/125C | 2.2 | 3 |
F 50/125B | 3 | 4 |
F 50/125A | 4 | 5.5 |
F 50/160C | 4 | 5.5 |
F 50/160B | 5.5 | 7.5 |
F 50/160A | 7.5 | 10 |
F 50/200C | 11 | 15 |
F 50/200B | 15 | 20 |
F 50/200A | 18.5 | 25 |
F 50/200AR | 22 | 30 |
F 50/250D | 9.2 | 12.5 |
--- | --- | --- |
F 50/250C | 11 | 15 |
F 50/250B | 15 | 20 |
F 50/250A | 18.5 | 25 |
F 50/250AR | 22 | 30 |
F 65/125C | 4 | 5.5 |
F 65/125B | 5.5 | 7.5 |
F 65/125A | 7.5 | 10 |
F 65/160C | 9.2 | 12.5 |
F 65/160B | 11 | 15 |
F 65/160A | 15 | 20 |
F 65/200B | 15 | 20 |
F 65/200A | 18.5 | 25 |
F 65/200AR | 22 | 30 |
F 65/250C | 30 | 40 |
F 65/250B | 37 | 50 |
F 65/250A | 45 | 60 |
F 80/160D | 11 | 15 |
F 80/160C | 15 | 20 |
F 80/160B | 18.5 | 25 |
F 80/160A | 22 | 30 |
F 80/200B | 30 | 40 |
F 80/200A | 37 | 50 |
F 80/250B | 45 | 60 |
F 80/250A | 55 | 75 |
F 100/160C | 15 | 20 |
F 100/160B | 18.5 | 25 |
F 100/160A | 22 | 30 |
F 100/200C | 30 | 40 |
F 100/200B | 37 | 50 |
F 100/200A | 45 | 60 |
F 100/250B | 55 | 75 |
F 100/250A | 75 | 100 |
CURVES AND PERFORMANCE DATA
– HS=0 m 50 Hz
F 32/160
TYPE| POWER (P2)|
1~
|
3~
| Q| m³/h| 0| 6| 9| 12| 15| 18| 21| 24| 27
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Single-ph.| Three-ph.| kW| HP| l/min| 0| 100| 150| 200| 250| 300| 350| 400|
450
Fm 32/160C| F 32/160C| 1.5| 2| IE2| IE3| H metres| 25| 24| 23.5| 22| 20.5|
18| 14| |
Fm 32/160B| F 32/160B| 2.2| 3| 31| 30| 29| 28| 26| 23.5| 20.5| 17|
–| F 32/160A| 3| 4| 38| 37| 36| 35| 33.5| 31.5| 30| 27.5| 24
F 32/200
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 6 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-ph. | kW | HP | l/min | 0 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | |
F 32/200C | 4 | 5.5 | IE3 | H metres | 46 | 44 | 43 | 41.5 | 40 | 38 | 36 | 34 | 31.5 | |
F 32/200B | 5.5 | 7.5 | 52 | 51 | 50.5 | 49 | 47 | 45 | 43 | 41 | 38.5 | 36 | ||
F 32/200A | 7.5 | 10 | 60 | 57 | 56.5 | 56 | 55 | 53.5 | 52 | 50 | 47 | 44 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits
F 32/200H
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 6 | 9 | 12 | 15 | 18 | 19.2 |
---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 100 | 150 | 200 | 250 | 300 | 320 | |
F 32/200BH | 3 | 4 |
IE3
| H metres| 47| 45| 44.5| 43| 40.5| 37|
F 32/200AH| 4| 5.5| 57| 55| 54| 52.5| 50| 46| 44
F 32/250
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 6 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | |
F 32/250C | 9.2 | 12.5 | IE3 | H metres | 76 | 75 | 74.5 | 73 | 71.5 | 69.5 | 67 | 64 | 60 | |
F 32/250B | 11 | 15 | 88 | 87 | 86 | 85 | 83 | 81 | 79 | 76.5 | 73.5 | 70 | ||
F 32/250A | 15 | 20 | 98 | 97 | 96 | 95 | 93 | 91 | 89 | 86.5 | 83.5 | 80 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits F 40/125
TYPE | POWER (P2) | 1~ | 3~ | Q | m³/h | 0 | 6 | 12 | 18 | 24 | 30 | 33 | 36 | 39 | 42 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single-phase | Three-phase | kW | HP | l/min | 0 | 100 | 200 | 300 | 400 | 500 | 550 | ||||
600 | 650 | 700 | |||||||||||||
Fm 40/125C | F 40/125C | 1.1 | 1.5 | IE2 | IE3 | H metres | 16 | 16 | 15.5 | 14 | 11.5 | ||||
8 | 6 | ||||||||||||||
Fm 40/125B | F 40/125B | 1.5 | 2 | 20.5 | 20.5 | 19.8 | 18.5 | 16 | 12.8 | 11 | 9 | ||||
– | F 40/125A | 2.2 | 3 | 26 | 26 | 25.5 | 24 | 22 | 18.5 | 17 | 14.5 | 12.5 | 10 |
F 40/160
TYPE | POWER (P2) | 1~ | 3~ | Q | m³/h | 0 | 6 | 9 | 12 | 15 | 18 | 24 | 30 | 36 | 42 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Single-phase | Three-phase | kW | HP | l/min | 0 | 100 | 150 | 200 | 250 | 300 | 400 | ||||
500 | 600 | 700 | |||||||||||||
Fm 40/160C | F 40/160C | 2.2 | 3 | IE2 | IE3 | H metres | 27 | 27 | 26.5 | 26 | 25.5 | 25 | |||
22.5 | 19 | 14 | |||||||||||||
– | F 40/160B | 3 | 4 | 32 | 32 | 31.5 | 31 | 30.5 | 30 | 27.5 | 24 | 20 | |||
– | F 40/160A | 4 | 5.5 | 38 | 38 | 37.8 | 37 | 36.5 | 36 | 33.5 | 30 | 26 | 20 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance
limits. F 40/200
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 6 | 9 | 12 | 15 | 18 | 24 | 30 | 36 | 42 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 100 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 700 | |
F 40/200B | 5.5 | 7.5 | IE3 | H metres | 48 | 47 | 46.5 | 46 | 45.5 | 44.5 | 42 | 38 | 34 |
28
F 40/200A| 7.5| 10| 56| 55| 55| 55| 54.5| 54| 52.5| 49.5| 46| 41
F 40/250
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 6 | 9 | 12 | 15 | 18 | 24 | 30 | 36 | 42 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 100 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | 700 | |
F 40/250C | 9.2 | 12.5 | IE3 | H metres | 64 | 64 | 63.5 | 63 | 62.5 | 62 | 60 | 56.5 | ||
52.5 | 47 | |||||||||||||
F 40/250B | 11 | 15 | 71 | 71 | 70.5 | 70 | 69.5 | 69 | 67 | 64 | 60 | 55 | ||
F 40/250A | 15 | 20 | 88 | 88 | 87.5 | 87 | 86.5 | 86 | 84 | 81 | 77 | 72 |
F 50/125
TYPE| POWER (P2)|
1~
|
3~
| Q| m³/h| 0| 18| 24| 30| 36| 42| 48| 54| 60| 66| 72
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Single-ph.| Three-ph.| kW| HP| l/min| 0| 300| 400| 500| 600| 700| 800| 900|
1000| 1100| 1200
Fm 50/125C| F 50/125C| 2.2| 3| IE2| IE3| H metres| 18.5| 17.5| 17| 16.5| 15.5|
14.8| 13.5| 12| 10.5| 8.2| 6
–| F 50/125B| 3| 4| 21.5| 20.7| 20| 19.5| 18.8| 17.8| 16.5| 15| 13.5| 11.2| 9
–| F 50/125A| 4| 5.5| 24.5| 23.5| 23| 22.5| 21.8| 20.8| 19.5| 18.3| 16.8| 15|
13
F 50/160
TYPE| POWER (P2)|
3~
| Q| m³/h| 0| 18| 24| 30| 36| 42| 48| 54| 60| 66| 72| 81
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Three-phase| kW| HP| l/min| 0| 300| 400| 500| 600| 700| 800| 900| 1000| 1100|
1200| 1350
F 50/160C| 4| 5.5| IE3| H metres| 27| 27| 26.5| 25| 24.5| 23| 20| 18.5| 16| |
|
F 50/160B| 5.5| 7.5| 33| 32| 31.7| 31| 30| 29| 27.4| 25.7| 23.5| 21| 18|
F 50/160A| 7.5| 10| 38| 37.5| 37| 36.5| 36| 35| 33.7| 32| 30.2| 28| 25| 20
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
F 50/200
TYPE| POWER (P2)|
3~
| Q| m³/h| 24| 36| 48| 60| 72| 84| 96| 102| 108
---|---|---|---|---|---|---|---|---|---|---|---|---|---
Three-phase| kW| HP| l/min| 400| 600| 800| 1000| 1200| 1400| 1600| 1700| 1800
F 50/200C| 11| 15| IE3| H metres| 44| 44| 44| 42| 39| 36| 33| 30|
F 50/200B| 15| 20| 52| 52| 52| 50| 47| 44| 40| 38|
F 50/200A| 18.5| 25| 61| 61| 60.5| 60| 57| 54| 50| 48| 45
F 50/200AR| 22| 30| 69| 69| 68.5| 68| 65| 62| 58| 56| 53
F 50/250
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 18 | 24 | 30 | 36 | 42 | 48 | 54 | 60 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 300 | 400 | 500 | 600 | 700 | 800 | 900 | 1000 | |
F 50/250D | 9.2 | 12.5 | IE3 | H metres | 51 | 50.5 | 49.5 | 48 | 45.5 | 43 | 40 | 37 | |
F 50/250C | 11 | 15 | 59 | 59 | 58 | 56.5 | 55 | 53 | 50 | 47 | 43 | ||
F 50/250B | 15 | 20 | 72 | 72 | 71 | 70 | 69 | 67 | 65 | 62 | 59 | ||
F 50/250A | 18.5 | 25 | 85 | 85 | 84 | 83 | 82 | 80 | 78 | 76 | 73 | ||
F 50/250AR | 22 | 30 | 95 | 95 | 94 | 93 | 92 | 90 | 88 | 86 | 83 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance
limits.
F 65/125
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 36 | 48 | 60 | 72 | 84 | 96 | 108 | 120 | 132 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 |
2200
F 65/125C| 4| 5.5| IE3| H metres| 16| 16| 16| 15.5| 14.5| 13.5| 12.5| 11| |
F 65/125B| 5.5| 7.5| 18| 18| 18| 18| 17| 16.5| 15.5| 14.5| 13|
F 65/125A| 7.5| 10| 23| 23| 23| 23| 22.5| 22.5| 22| 21| 19.5| 18
F 65/160
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 36 | 48 | 60 | 72 | 84 | 96 | 108 | 120 | 132 | 144 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | |||
2200 | 2400 | ||||||||||||||
F 65/160C | 9.2 | 12.5 | IE3 | H metres | 32 | 32 | 32 | 32 | 32 | 30 | 29 | 27 | 25 | 22 | |
F 65/160B | 11 | 15 | 37 | 36.5 | 36.5 | 36 | 35.5 | 34 | 33 | 31 | 29 | 26 | 23 | ||
F 65/160A | 15 | 20 | 41 | 40.5 | 40.5 | 40 | 39.5 | 39 | 37.5 | 36 | 34 | 31 | 28 |
Q = Flow rate
H = Total manometric head
HS = Suction heigh
Performance curves comply with EN ISO 9906 Grade 3B tolerance
limits. F 65/200
TYPE| POWER (P2)| 3~| Q| m³/h| 12| 36| 48| 60| 72| 84| 96| 108| 120| 132| 144|
150| 156
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Three-phase| kW| HP| l/min| 200| 600| 800| 1000| 1200| 1400| 1600| 1800| 2000|
2200| 2400| 2500| 2600
F 65/200B| 15| 20| IE3
| H metres
| 44| 43.5| 43.3| 43| 42.5| 41.5| 40| 38.5| 36.5| 34| 30.5| |
F 65/200A| 18.5| 25| 50| 50| 50| 49.5| 49| 48| 46.5| 45| 43| 41| 38| 36.5|
F 65/200AR| 22| 30| 57| 57| 57| 56| 55.5| 54.5| 53.5| 52| 50| 48| 45.5| 43.5|
42
F 65/250
TYPE | POWER (P2) | 3~ | Q | m³/h | 24 | 40 | 60 | 80 | 100 | 120 | 141 | 150 | 156 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 400 | 667 | 1000 | 1333 | 1667 | 2000 | 2350 | 2500 | 2600 | |
F 65/250C | 30 | 40 | IE3 | H metres | 76 | 76 | 75.5 | 72.5 | 68 | 61.5 | 53 | ||
F 65/250B | 37 | 50 | 87 | 87 | 86 | 84 | 80 | 74 | 66.5 | 62 | |||
F 65/250A | 45 | 60 | 95 | 95 | 94 | 92 | 88 | 82.5 | 75 | 71 | 68 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
F 80/160
TYPE | POWER (P2) | 3~ | Q | m³/h | 0 | 30 | 60 | 90 | 120 | 150 | 180 | 210 | 240 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 0 | 500 | 1000 | 1500 | 2000 | 2500 | 3000 | 3500 | 4000 | |
F 80/160D | 11 | 15 | IE3 | H metres | 25 | 25 | 25 | 24.5 | 23.5 | 21 | 18 | 14.5 | 10 |
F 80/160C | 15 | 20 | 30 | 30 | 30 | 29.5 | 28.5 | 26 | 23 | 19.5 | 15 | ||
F 80/160B | 18.5 | 25 | 35 | 35 | 35 | 34.5 | 33.5 | 31 | 28.5 | 24.5 | 20 | ||
F 80/160A | 22 | 30 | 40 | 40 | 40 | 39.5 | 38.5 | 36 | 33 | 29.5 | 25 |
F 80/200
TYPE | POWER (P2) | 3~ | Q | m³/h | 30 | 50 | 100 | 150 | 200 | 219 | 234 |
---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 500 | 833 | 1667 | 2500 | 3333 | 3650 | 3900 | |
F 80/200B | 30 | 40 | IE3 | H metres | 56 | 56 | 54 | 49 | 41 | 34.5 | |
F 80/200A | 37 | 50 | 62 | 62 | 61 | 57 | 50 | 45.5 | 40 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
F 80/250
F 80/250
TYPE | POWER (P2) | 3~ | Q | m³/h | 36 | 50 | 100 | 150 | 200 | 216 | 234 |
---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 600 | 833 | 1667 | 2500 | 3333 | 3600 | 3900 | |
F 80/250B | 45 | 60 | IE3 | H metres | 77 | 77.5 | 76 | 70.5 | 58.5 | 54 | |
F 80/250A | 55 | 75 | 88.5 | 89.5 | 89 | 83 | 72 | 68 | 60 |
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
F 100/160
TYPE| POWER (P2)| 3~| Q| m³/h| 60| 90| 120| 150| 180| 210| 240| 270| 300| 312|
330
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Three-phase| kW| HP| l/min| 1000| 1500| 2000| 2500| 3000| 3500| 4000| 4500|
5000| 5200| 5500
F 100/160C| 15| 20| IE3| H metres| 30| 29| 27.5| 25.5| 23.5| 21| 18.5| 15.5|
12| |
F 100/160B| 18.5| 25| 34| 33| 31.5| 30| 28| 25.5| 22.5| 19.5| 16| 14.5|
F 100/160A| 22| 30| 38| 37| 36| 34| 32| 30| 27.5| 24.5| 21| 20| 17.5
F 100/200
TYPE| POWER (P2)| 3~| Q| m³/h| 0| 50| 96| 150| 180| 210| 240| 279| 294| 300|
315
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Three-phase| kW| HP| l/min| 0| 833| 1600| 2500| 3000| 3500| 4000| 4650| 4900|
5000| 5250
F 100/200C| 30| 40| IE3| H metres| 51| 51| 50| 47| 44| 40.5| 35.5| 28| | |
F 100/200B| 37| 50| 57| 57| 56| 53| 50.5| 47| 42.5| 36| 33| |
F 100/200A| 45| 60| 63| 63| 62.5| 60| 58| 55| 51.5| 45| 42.5| 41.5| 38
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
F 100/250
TYPE | POWER (P2) | 3~ | Q | m³/h | 48 | 96 | 150 | 180 | 210 | 240 | 300 | 309 | 345 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Three-phase | kW | HP | l/min | 800 | 1600 | 2500 | 3000 | 3500 | 4000 | 5000 | 5150 |
5750
F 100/250B| 55| 75| IE3| H metres| 75| 75| 73| 71| 68| 64| 50.5| 48|
F 100/250A| 75| 100| 89| 89| 87.5| 86| 83.5| 80.5| 70| 68| 58
Q = Flow rate
H = Total manometric head
HS = Suction height
Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.
ABSORPTION
TYPE
|
VOLTAGE
---|---
Single-ph.| 230 V
Fm 32/160C| 11.0 A
Fm 32/160B| 12.0 A
Fm 40/125C| 8.0 A
Fm 40/125B| 10.0 A
Fm 40/160C| 15.0 A
Fm 50/125C| 13.5 A
TYPE
|
VOLTAGE
---|---
Three-phase| 230 V –| 400 V –| 400 V –| 690 V –
F 32/160C| 7.4 A| 4.3 A| –| –
F 32/160B| 8.6 A| 5.0 A| –| –
F 32/160A| 12.1 A| 7.3 A| –| –
F 32/200C| 17.8 A| 10.3 A| –| –
F 32/200B| –| –| 11.7 A| 6.8 A
F 32/200A| –| –| 14.9 A| 8.6 A
F 32/200BH| 12.6 A| 7.3 A| –| –
F 32/200AH| 15.4 A| 8.9 A| –| –
F 32/250C| –| –| 18.5 A| 10.7 A
F 32/250B| –| –| 22.0 A| 12.7 A
F 32/250A| –| –| 25.0 A| 14.5 A
F 40/125C| 5.2 A| 3.0 A| –| –
F 40/125B| 7.7 A| 4.5 A| –| –
F 40/125A| 9.0 A| 5.2 A| –| –
F 40/160C| 9.9 A| 5.7 A| –| –
F 40/160B| 12.6 A| 7.3 A| –| –
F 40/160A| 17.1 A| 9.9 A| –| –
F 40/200B| –| –| 12.6 A| 7.3 A
F 40/200A| –| –| 15.6 A| 9.0 A
F 40/250C| –| –| 21.0 A| 12.1 A
F 40/250B| –| –| 23.5 A| 13.6 A
F 40/250A| –| –| 30.5 A| 17.6 A
F 50/125C| 9.3 A| 5.4 A| –| –
F 50/125B| 13.1 A| 7.6 A| –| –
F 50/125A| 16.3 A| 9.4 A| –| –
F 50/160C| 15.7 A| 9.1 A| –| –
F 50/160B| –| –| 12.3 A| 7.1 A
F 50/160A| –| –| 15.5 A| 9.0 A
F 50/200C| –| –| 23.0 A| 13.3 A
F 50/200B| –| –| 29.5 A| 17.1 A
F 50/200A| –| –| 34.5 A| 19.9 A
F 50/200AR| –| –| 41.5 A| 24.0 A
F 50/250D| –| 19.0 A| 19.0 A| 11.0 A
---|---|---|---|---
F 50/250C| –| 21.0 A| 21.0 A| 12.1 A
F 50/250B| –| 27.0 A| 27.0 A| 15.6 A
F 50/250A| –| 34.0 A| 34.0 A| 19.7 A
F 50/250AR| –| 41.0 A| 41.0 A| 23.7 A
F 65/125C| 17.3 A| 10.0 A| –| –
F 65/125B| –| 12.0 A| 12.0 A| 6.9 A
F 65/125A| –| 16.5 A| 16.5 A| 9.5 A
F 65/160C| –| 19.0 A| 19.0 A| 11.0 A
F 65/160B| –| 23.0 A| 23.0 A| 13.3 A
F 65/160A| –| 27.5 A| 27.5 A| 15.9 A
F 65/200B| –| 30.0 A| 30.0 A| 17.3 A
F 65/200A| –| 34.0 A| 34.0 A| 19.7 A
F 65/200AR| –| 41.0 A| 41.0 A| 23.7 A
F 65/250C| –| 53.0 A| 53.0 A| 30.6 A
F 65/250B| –| 65.0 A| 65.0 A| 37.6 A
F 65/250A| –| 79.0 A| 79.0 A| 45.7 A
F 80/160D| –| 22.0 A| 22.0 A| 12.7 A
F 80/160C| –| 29.0 A| 29.0 A| 16.8 A
F 80/160B| –| 34.5 A| 34.5 A| 19.9 A
F 80/160A| –| 39.0 A| 39.0 A| 22.5 A
F 80/200B| –| 53.0 A| 53.0 A| 30.6 A
F 80/200A| –| 65.0 A| 65.0 A| 37.6 A
F 80/250B| –| 79.0 A| 79.0 A| 45.7 A
F 80/250A| –| 98.0 A| 98.0 A| 56.6 A
F 100/160C| –| 27.5 A| 27.5 A| 15.9 A
F 100/160B| –| 32.5 A| 32.5 A| 18.8 A
F 100/160A| –| 39.8 A| 39.8 A| 23.0 A
F 100/200C| –| 53.0 A| 53.0 A| 30.6 A
F 100/200B| –| 65.0 A| 65.0 A| 37.6 A
F 100/200A| –| 79.0 A| 79.0 A| 45.7 A
F 100/250B| –| 98.0 A| 98.0 A| 56.6 A
F 100/250A| –| 126.0 A| 126.0 A| 72.8 A
MATERIALS AND COMPONENTS
1 | Pump body | Cast iron, fitted with inlet and outlet flanged ports |
---|---|---|
2 | Cover/Motor bracket | Cast iron |
3 | Impeller | Brass Cast iron |
F40/200 – F50/125 – F50/160
for F32/250 – F40/250 – F50/200 – F50/250 – F65/125 – F65/160 – F65/200 –
F65/250
F80/160 – F80/200 – F80/250 – 1100/160 – F100/200 – F100/250
4| Mechanical seal| Water pump| Seal| Shaft| Materials
F32/160 – F40/125 – F40/160 – F50/125| FN-20| 0 20 mm| Graphite
Ceramic
NBR
F32/200 – F40/200 – F50/160 – F65/125| FN-24| 0 24 mm
F50/200 – F65/160 – F65/200 – F80/160 – F100/160| FN-32 NU| 0 32 mm
F32/250 – F40/250 – F50/250| FN-38| 0 38 mm
F32/250 – F40/250 – F50/250
F65/250 – F80/200 – F80/250B – F 100/200| FN-40 NU| 0 40 mm
F80/250A – F100/250| FH-45 NU| 0 45 mm
5| Motor shaft| Stainless steel A151431
6| Electric motor| Fm: single-phase 230 V – 50 Hz with winding integrated
thermal motor protection (up to 1.5 kW)
F: three-phase 230/400 V SO Hz up to 4 kW – 400/690 V 50 Hz from 5.5 to 75 kW
※ Pumps are equipped with high-efficiency motors (IEC 60034-30-1)
class 1E2 for single-phase models
class 1E3 for three-phase models
Continuous running duty 51
Technical data
DIMENSIONS AND WEIGHT
DIMENSIONS AND WEIGHT
TYPE | PORTS | DIMENSIONS mm | kg |
---|---|---|---|
Three-ph. | DN1 | DN2 | a |
F 65/250C | 80 | 65 | 100 |
211.0
F 65/250B| 225.0
F 65/250A| 239.0
F 80/200B| 100| 80| 125| 837| 200| 250| 450| 25| 372| 360| 318| 217.5| 305|
19| 203.0
F 80/200A| 218.0
F 80/250B| 834| 280| 480| 5| 390| 214.5| 249.0
F 80/250A| 1015| 250| 620| 55| 490| 490| 400| 294| 350| 24| 547.0
F 100/200C| 125| 100| 125| 839| 200| 280| 480| –| 395| 360| 318| 219.5| 305|
19| 217.0
F 100/200B| 231.0
F 100/200A| 245.0
F 100/250B| 140| 1060| 250| 280| 620| 40| 485| 485| 406| 313| 350| 24| 551.2
F 100/250A| 544.3
PORT FLANGES
DN FLANGE
| D| K|
HOLES
---|---|---|---
mm| mm| mm| N°| Ø (mm)
32| 140| 100| 4| 18
40| 150| 110
50| 165| 125
65| 185| 145
80| 200| 160| 8
100| 220| 180
125| 250| 210
COUNTER-FLANGE
(CAN BE ORDERED SEPARATELY)
DN FLANGE
| F| D| K|
HOLES
---|---|---|---|---
mm| COUNTER-FLANGE| mm| mm| N°| Ø (mm)
32| 1¼”| 140| 100| 4| 18
40| 1½”| 150| 110
50| 2″| 165| 125
65| 2½”| 185| 145
80| 3″| 200| 160| 8
100| 4″| 220| 180
125| 5″| 250| 210
Read User Manual Online (PDF format)