PEDROLLO CP 160 Centrifugal Pumps User Guide

June 1, 2024
pedrollo

PEDROLLO CP 160 Centrifugal Pumps

Centrifugal pumps

PERFORMANCE RANGE

  • Flow rate up to 900 l/min (54 m3/h)
  • Head up to 76 m

INSTALLATION AND USE

Designed to transfer clean water free from abrasive particles and liquids that will not damage the pump’s components.
Reliable and easy to operate, these pumps are widely used in civil, agricultural, and industrial settings for water supply, air conditioning and cooling systems, and irrigation purposes.

ELECTRIC MOTOR

Equipped with cutting-edge electric motors, the three phase pumps are designed to work with inverters, offering stable and noiseless performance.
They feature efficiency class IE3 for three-phase motors and IE2 for single-phase motors, bolstered by class F insulation and IPX4 protection for models CP160 and CP210, and IPX5 protection for models CP220, CP230, and CP250.

APPLICATION LIMITS

  • Manometric suction head up to 7 m
  • Liquid temperature between -10 °C and +90 °C
  • Ambient temperature between -10 °C and +40 °C
  • Maximum working pressure 10 bar

AVAILABLE UPON REQUEST

  • Mechanical seal options available
  • Pump shaft in stainless steel AISI 316 – EN 10088-3 – 1.4401 for CP 220, CP 230, CP 250
  • Protection rating IP X5 for CP 160 and CP 210
  • Different voltage requirements 60 Hz frequency

PATENTS – TRADE MARKS – MODELS

  • Registered community model No. 002098434 for CP 160, CP 210, CP 250
  • Italian registered model no. 72753 for CP 220, CP 230

Feature

  • Clean water

  • Civil use

  • Agricultural use

  • Industrial use

CURVES AND PERFORMANCE DATA – HS=0 m 50 Hz

CP 160

TYPE| POWER (P2)| 1~| 3~| Q| m³/h| 0| 3| 4.5| 6| 7.5| 9| 10.5| 12| 13.2| 14.4
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Single-ph.| Three-ph.| kW| HP| l/min| 0| 50| 75| 100| 125| 150| 175| 200| 220| 240
CPm 160C| CP 160C| 1.1| 1.5| IE2| IE3| H metres| 32| 31| 30.5| 29.5| 28| 26| 23| 20|  |
CPm 160B| CP 160B| 1.5| 2| 37| 36| 35.5| 34.5| 33.5| 31.5| 29| 26.5| 23|
CPm 160A| CP 160A| 2.2| 3| 43| 42| 41.5| 40.5| 39.5| 38| 35.5| 33| 30| 26

Curves And Performance Data – Hs=0 M 50 Hz 

CP 210

TYPE

Three-ph.

| POWER (P2)| 3~| Q| m³/h| 0| 3| 4.5| 6| 7.5| 9| 10.5| 12| 13.2| 14.4| 15| 16.2| 16.8
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
kW| HP| l/min| 0| 50| 75| 100| 125| 150| 175| 200| 220| 240| 250| 270| 280
CP 210B| 3| 4| IE3| H metres| 54| 53| 52| 51| 49.5| 48| 45.5| 43| 40| 38.5| 37| 34|
CP 210A| 4| 5.5| 61| 61| 60| 59| 57.5| 56| 53.5| 51| 49| 46.5| 45| 42| 40

Curves And Performance Data – Hs=0 M 50 Hz 

CURVES AND PERFORMANCE DATA – HS=0 m

CP 220

TYPE| POWER (P2)| 1~| 3~| Q| m³/h| 0| 3| 6| 12| 18| 24| 30| 33| 36
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Single-phase| Three-phase| kW| HP| l/min| 0| 50| 100| 200| 300| 400| 500| 550| 600
CPm 220C| CP 220C| 2.2| 3| IE2| IE3| H metres| 34| 34| 33.5| 32| 29| 24.3| 18| 14|
| CP 220B| 3| 4| 38| 38| 37.5| 36| 33| 28.5| 22| 18|
| CP 220A| 4| 5.5| 49| 48.5| 48| 46| 42.5| 38| 32| 29| 25
| CP 220AH| 5.5| 7.5| 54.5| 54.5| 54| 52.5| 50| 46| 40.5| 37| 33

Curves And Performance Data – Hs=0 M

CP 230

TYPE

Three-phase

| POWER (P2)| 3~| Q| m³/h| 0| 6| 12| 18| 24| 30| 36| 42| 48| 51| 54
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
kW| HP| l/min| 0| 100| 200| 300| 400| 500| 600| 700| 800| 850| 900
CP 230C| 3| 4| IE3| H metres| 30| 29.5| 28.5| 27| 25| 22| 19.5| 15.5| 11.5| 9|
CP 230B| 4| 5.5| 39| 38.5| 38| 36| 34| 31| 28| 24| 18.5| 15| 13
CP 230A| 5.5| 7.5| 46| 45.5| 44.5| 42| 40| 37| 32.5| 27.5| 21.5| 18| 15

Curves And Performance Data – Hs=0 M

CP 250

TYPE

Three-phase

| POWER (P2)| 3~| Q| m³/h| 0| 6| 12| 18| 24| 30| 36| 42| 48| 54
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
kW| HP| l/min| 0| 100| 200| 300| 400| 500| 600| 700| 800| 900
CP 250B| 7.5| 10| IE3| H metres| 57| 57| 56.5| 54.5| 52| 48.5| 44| 38| 31|
CP 250A| 11| 15| 76| 76| 75| 73.5| 71| 67.5| 63| 58| 52| 45

Curves And Performance Data – Hs=0 M

Q = Flow rate H = Total manometric head HS = Suction height

Performance curves comply with EN ISO 9906 Grade 3B tolerance limits.

ABSORPTION

TYPE Single-phase VOLTAGE 230 V
CPm 160C 8.5 A
CPm 160B 10.3 A
CPm 160A 13.0 A
CPm 220C 14.2 A

TYPE

Three-ph.

| VOLTAGE
---|---
230 V – t| 400 V – s| 400 V – t| 690 V – s
CP 160C| 5.7 A| 3.3 A| –| –
CP 160B| 6.9 A| 4.0 A| –| –
CP 160A| 8.8 A| 5.1 A| –| –
CP 210B| 12.6 A| 7.3 A| –| –
CP 210A| 15.1 A| 8.7 A| –| –
CP 220C| 9.0 A| 5.2 A| –| –
CP 220B| 12.6 A| 7.3 A| –| –
CP 220A| 17.0 A| 9.8 A| –| –
CP 220AH| –| –| 11.5 A| 6.6 A
CP 230C| 13.1 A| 7.6 A| –| –
CP 230B| 16.8 A| 9.7 A| –| –
CP 230A| –| –| 11.5 A| 6.6 A
CP 250B| –| –| 15.0 A| 8.7 A
CP 250A| –| –| 22.5 A| 13.0 A

Technical data

DIMENSIONS AND WEIGHT

TYPE PORTS DIMENSIONS mm kg
Single-ph. Three-ph. DN1 DN2
n2 w s 1~
CPm 160C CP 160C 1½” 1″
206 165 44.5 11
CPm 160B CP 160B 20.0 20.0
CPm 160A CP 160A 390 22.7
CP 210B 60 454
CP 210A 37.2
CPm 220C CP 220C 2″ 2″
230 170 40 14
CP 220B 70 468
CP 220A 41.0
CP 220AH 47.0
CP 230C 37.2
CP 230B 41.0
CP 230A 46.0
CP 250B 65 519
CP 250A 570

Dimensions And Weight

PALLET CAPACITY

TYPE NO. OF PUMPS
Single-ph. Three-ph.
CPm 160C CP 160C
CPm 160B CP 160B
CPm 160A CP 160A
CP 210B
CP 210A
TYPE NO. OF PUMPS
--- ---
Single-ph. Three-ph.
CPm 220C CP 220C
CP 220B
CP 220A
CP 220AH
CP 230C
CP 230B
CP 230A
CP 250B
CP 250A

CONSTRUCTION FEATURES

1 Pump body Cast iron with ISO 228/1 threaded ports
2 Cover Cast iron
3 Impeller Stainless steel for CP160 Brass for CP 210, CP 220, CP 230 Cast

iron for CP 250
4| Mechanical sea| | Pump| Sea| Shaft| Materials
---|---|---|---
CP 160C-B-A| FN-18| Ø 18 mm| Graphite / Ceramic / NBR
CP 220C| FN-20| Ø 20 mm| Graphite / Ceramic / NBR
CP 210B-A|
CP 220B-A-AH|
CP 230C-B-A| FN-24| Ø 24 mm| Graphite / Ceramic / NBR
CP 250B|
CP 250A| FN-32 NU| Ø 32 mm| Graphite / Ceramic / NBR
5| Motor shaft| Stainless steel AISI 431
6| Electric motor| CPm: single-phase 230 V – 50 Hz.
CP: three-phase 230/400 V – 50 Hz up to 4 kW. 400/690 V – 50 Hz from 5.5 to 11 kW.
※ Pumps are equipped with high-efficiency motors (IEC 60034-30-1)
class IE2 for single-phase models
class IE3 for three-phase models Continuous running duty S1

Construction Features

Logo

Documents / Resources

| PEDROLLO CP 160 Centrifugal Pumps [pdf] User Guide
CP 160 Centrifugal Pumps, CP 160, Centrifugal Pumps, Pumps
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

pedrollo User Manuals

Related Manuals