SANOTECHNIK SPA08 Outdoor Swimming Pools Instruction Manual

June 13, 2024
SANOTECHNIK

SANOTECHNIK SPA08 Outdoor Swimming Pools

SANOTECHNIK-SPA08-Outdoor-Swimming-Pools-product

Product Information

  • Product Name : SPA Outdoorpool
  • Models : SPA08, SPA09, SPA10, SPA11, SPA12, SPA13, SPA14, SPA15

Product Usage Instructions

  1. Cleaning
    • Cleaning the Surrounding Area
    • Cleaning the Cover
    • Cleaning the Whirlpool
  2. Warning
    • Warning Notes
    • Warning Notes for the Pump System
    • Grounding Connection
    • Danger of Electrical Shock
  3. Installation Instructions
    • Location Selection and Preparation
    • Transportation Routes – Electrical Connection
  4. Cover
    • Instructions for using the cover
  5. Operation Instructions
    • Display Panel with Controls
    • Radio Settings and Locking the Keyboard
    • Jet Pump 1 On/Off
    • Cycle Setting and Preheating
  6. Initial Operation / Active / Passive Mode
    • Switching between Active and Passive Mode
  7. Setting the Time
  8. Filter Times / Cleaning
  9. Heating / Preheating
    • Setting the Start Time of Heating

Please refer to the user manual for detailed instructions on each step and for additional information on using the SPA Outdoor pool.1. WARNINGS
Before installing the massage pool, observe the installation instructions, pay particular attention to

SAFETY PRECAUTIONS

  • Explain the instructions for use to the children first. Before doing this, do not allow them to use the massage pool. Even later, children should use the pool without supervision of an adult. If you have also ordered a cover, please note that this area is many times used by children as a playing area; the cover is not meant for that, because it can break. When you are not using the massage pool, always cover it and fix the cover accordingly.
  • The water in the massage pool must not exceed 40 ° C. The most suitable temperature for a healthy adult is between 38 ° C and 40 ° C. This temperature is not suitable for young children! Use at lower water temperatures (for children) is recommended only for shorter time intervals – max. 10 minutes. Pregnant women in the first months of pregnancy are not advised to use a massage pool. If they still use it, it’s max. recommended temperature 38 ° C.
  • Before using the pool, check the temperature of the water with the thermometer as the temperature displayed on the controller may deviate from the actual temperature. Consumption of alcohol, drugs or strong medicines can cause unconsciousness and consequent drowning!
  • If you are overweighted, have heart or circulatory problems or you are a diabetic, please consult your doctor before using the massage pool.
  • If you take any medications; combined with fever may result in increased sleepiness and consequent drowning. In this case also consult your doctor before using the pool.
  • Do not immerse yourself in the massage pool, as hypertension may occur. Hypertension occurs when the body is heated to a temperature higher than 38 ° C. Consequences: drowsiness, dizziness, vertigo, unconsciousness.
  • Make sure that the massage pool is properly connected, grounded, and that the connection cable is stored in a safety box.
  • Check the temperature of the water before entering, also by hand, to make sure that the temperature is appropriate.
  • Wet surfaces are slippery, so avoid walking along the edge of the massage pool.

SAFETY PRECAUTIONS – PUMP
Do not change the suction pipe positions, as these are set to the proper flow of water and the operation of the water pump. In case of replacement of the pump, please contact the seller where you purchased the massage pool.

EARNING
Please use appropriate earthing / potential compensation.

DANGER OF ELECTRIC SHOCK
The massage pool should be at least 1.5 m away from all iron objects to avoid electrostatic discharge. If this is not possible, such objects must also be grounded!

INSTALLATION / INSTALLATION INSTRUCTIONS

SITE SELECTION / PREPARATION
Place the massage pool on a perfectly level surface. In the immediate vicinity there should be the possibility of an electric and water connection and a drainage of water. If possible, place it so that it is accessible from all four pages.

WIND PROTECTION
Place the massage pool in the backyard, where there is not much windy!

SUITABLE PLACE FOR INSTALLATION
Before installing the pool, check if there are any local regulations for placing the pools.

TRANSPORTATION
Doors, stairs or passages can hinder you when the massage pool is set up to the desired location, so make sure that the transport paths are free and wide enough.

ELECTRICAL CABLE CONNECTION / SUPPLY
We recommend that you hire an electrician to connect to the electric network (connection to the home network, as well as to connect the electronics to the massage pool itself).

  • The massage pool must not be connected to a home network with a regular socket, except SPA 8 and 9, but with a stable electrical line, as it must be permanently connected to the electricity
  • this way it can be prevented from freezing. If you do not follow the installation and connection instructions, there may occur a damage to the massage pool and therefore a loss of warranty.
  • When connecting, local regulations must be followed.
  • There is a diagram on the control box cover (check the picture).
  • The connection of the supply line must be correctly dimensioned and established by a local electrician!
  • To make the connection correct, use the intended connections inside the control box (see page 9).
  • All wiring, including electrical, is pre-assembled. Do not drill additional holes or make any other operations into the control box. If the control box is damaged, the warranty becomes invalid.

Removing the safety protection
First, remove both strips; left and right (Picture 1 and 2). Reach into the holes and pull out the panel. Then press gently to remove the panel (Picture 3). Be careful with speaker cables and lighting (if they belong to your model) to avoid tearing them out of the chassis.SANOTECHNIK-SPA08-Outdoor-Swimming-
Pools- \(1\) SANOTECHNIK-SPA08-Outdoor-Swimming-
Pools- \(2\)Electrical connection of the massage pool
Open the cover on the side of the screen. Under the hood there is a connector. Then unscrew the screws from the control box (Picture 4). Remove the transparent protection from the connectors (Picture 6).

SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(3\) The control box contains 4 connectors and a grounding connector located at the bottom (Picture 7). Connect the electrical conductor to the cabinet through the hole 20, which is drilled to protect the bottom of the pool (Figure 3). Connection is possible to 220V / 230V or 380V / 400V.
Please note that the massage pool can only be used via the RCD (FID) protective switch!!! The RCD (FID) switch should be located in the fuse locker box.

COVER
If you have also purchased a massage pool cover, it should always be covered, as this saves a lot of electricity. If you have children, we recommend using numerical protection, the combination of which is preset at 0-0. To open the cover, press both clamps simultaneously and pull the strap out of the lock. To change the numeric combination of the lock, unlock and open it first, then use, for example, office clamp and press the RESET key. Hold down the key until you select the new combination. Repeat the same on the other side.
Take note! Never lie, stand or sit on the cover!

INSTRUCTION FOR USE

FILLING OF THE OUTDOORPOOL
Before you start filling the pool, wipe it with a damp cloth to remove any residual particles from the installation. Begin by draining the water and observe if water may leak in any location; This can happen due to vibration generated during transport.
Pour the water minimum to the water level mark (picture below, they are located on the left side). If you pour less water, the protection against dry running is activated. In this case, no pump works, nor does it heat. On the right side of the picture, it is visible to which border you can fill the water (drain) so that it does not overflow. The outflow is not intended to swallow excessive amounts of After completing the filling, it is necessary to check the water parameters, PH value (7,0-7,4) and chlorine content (0,6-1,0 mg / m3), which are regulated with pool maintenance equipment. Irregular parameters can cause poor water quality, eye irritation, irritated skin, oxidation of basement parts and formation of limescale

Illustrations to buttons

SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(6\) SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(7\)

FIRST USE /ACTIVE / PASSIVE – MANNER
When first turning on the power, the backlight will bright of halt, and the LCD will show the present time and temperature. It will show “E1” if the sensor is open/short circuit. When part of radio frequency showed “—“, it indicates that the status of the system is “Waitting Mode”, so as well as the pre-heat and circulation cleaning.

The lock will start work by pressing (MEM. Button in the status of “Waiting Mode”or no- pressing operation lasting above 30 minute. In the status of Locked, press the button MEM twice, the lock will be unlocked, and the word “LOCKED” will disappear.

SETTING THE TIME
In the status of “Waitting Mode” and the pre-heater and circulation cleaning are shut down, pressing – or could start time setting. Signal of “:” doesn’t flash but Minute and Hour flash at this time. It will add 1 hour when pressing – each time, and the hours could be added continually when pressing the – without stop. The hour adjustment range is 0-23. In the status of time setting, It will add 1 minute when pressing ( . each time, and the minutes could be added continually when pressing the ( without stop. the minute adjustment range of the minute is: 0-59. The system will quit the time-setting status automatically after 6 seconds without pressing.

FILTERING AND CLEANING

  • You have the option to set ones a day filtering in the pool, but it can also be all the time on. To set a ones a day filtering then press in passive manner, then press or to set the start time of the filtering.
  • Then press . Now you can use the or button to set the duration of the filtering.
  • The maximum filter time is 19 hours and 55 minutes! To exit settings, press to prevent your filter settings from being saved. However, if you press , your filtering settings will be saved.
  • When you have saved the settings a filtering sign appears on the screen.
  • When the clock you set for filtering appears, the circular pump turns on and the water cleaning starts. It does not matter if the operation is in active or passive mode, the cleaning is switched on in each case.
  • The screen shows the cleaning time, which is counting down. In the initial 30 seconds of cleaning a jet massage pump is also active to purify the inlet and outlet pipes of the pool. In the first 59 seconds of cleaning, this procedure can not be interrupted. After 1 minute by pressing you can cancel filtering.
  • To activate a permanent filtering without a timeout, in active mode press ” filtering begins the same as described above, but does not stop automatically. “. Process of

HEATING / PREHEATING
You can also set this program to be active once a day or is active continuously. For the daily pre- heating setting in passive mode press then press ( ) or . to set the initial heating time. The minimum heating time is 5 minutes and increases with each pressure of ( for 10 minutes. Press ( ). Now you can set the heating time with the ( or The maximum preheat time is 19 hours and 50 minutes! Press ( )” again. Now you can press to set the water temperature between 15 ° C and 42 ° C. To exit this menu, press , so your settings will not be saved. But if you press your settings will be saved. When you have saved the settings, “ON” appears on the screen. If you pressed “OFF” appears on the display.

SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(19\)has been reached or when it has expired the time, set for heating. In the first 59 seconds the heating can not be switched off. After 1 minute you can switch off the heating by pressing .
To set the uninterrupted heating without turning off, press in active mode. Now the heating is switched on and is in operation together with a circular pump until the desired temperature is reached. You can keep the temperature on the next way:
Set the temperature to 35 ° C. When the temperature drops to 34 ° C, the heating is switched on together with the circular pump and heats water at 36 ° C and then switches off, etc. …

FREEZING PROTECTION
The massage pool has built-in protection against freezing. It is activated if the water temperature falls below 5 ° C. Heating is switched on until 10 ° C is reached.

RADIO/CD/AUX
In active mode, press   to activate the radio. The antenna is located in the control box, which was curled and fastened in the hinge for transportation. Develop it and install it so that you will have a good reception.

The preset frequency is displayed on the screen. By pressing or you can search for radio stations. Once you have found the correct station, you can save it to one of the 10 stations by pressing . To switch to one of the saved stations, press press MEM to select between saved stations. By pressing again, you can switch to the CD / AUX mode in which you can connect over 2 RCA connections in the control box (electrical housing) to any audio source. By pressing again, everything altogether turns off, and you can start again from the beginning. Use the and keys or to adjust the volume. If you want to use the radio on the dashboards, you need to connect the speakers to the electronics output. The speakers are factory-connected to Bluetooth.

LIGHTING
Press 1 time and LED-s start to light. You can let it be a color combination replaces automatically, or press again and with that keeping the color illumination that illuminates at the moment of pressing the key. When you press again, turn off the illumination.

BLUETOOTH-RADIO PLAYER YS-02

Thank you for using this Bluetooth-radio player. The player has the following features

  • Simple operation, powerful sound effect, combine the functions of Radio and Bluetooth in one.
  • Strong applicability and wide compatibility.
  • It is suitable for a variety of mobile phones It can connected to two speakers and one subwoofer and is widely used in swimming pools,
  • spa bath, sauna, steam room and outdoor pavilions etc.

SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(23\)

Kommand panel: Bluetooth

INDICATOR LIGHTS: green light is in PROGRAMMING INSTRUCTIONS radio status; blue light is in Bluetooth status;

  • PREVIOUS / INCREASING button: change to previous song or increase sound volume
  • NEXT / DECREASING button: change to next song or decrease sound volume
  • TUN / VOL button : Radio channel searching and sound volume setting
  • MODE / OFF button: switch among Radio, Bluetooth and Power off.

THE OPERATING INSTRUCTIONS

  1. On the base control panel switch to the position CD/AUX
  2. First press Mi button, the system enters Radio status (the indicator light of it is green); Second press of button, the system enters Bluetooth status (the indicator light of it is blue); Third press button to turn off the player.
  3. When the system enters the radio (FM) mode, long press button for 3 seconds, the system starts searching and store radio channels automatically and then return to first channel. Pressing button and button to select the stored radio channels.
  4. When the system enters the Bluetooth status, scan and find the player in your cell phone with the name “YS-02”. After the pairina is completed, play the music in your cell phone. Pressing button to next song and button to previous song.
  5. When the player is in Radio or Bluetooth status, press button and then button and button to adjust the sound volume.

MASSAGE NAVES/MASSAGE PUMP
To activate or deactivate the massage pump in active mode press . The massage pool is designed to provide maximum enjoyment and take up minimal space. There are several different massage nozzles. With most massage nozzles (not all!) pressure can be further adjusted by turning the external chromed ring (Picture 15). Thus, the effect of the massage can be adjusted to the individual user. In addition to changing the pressure of the massage jet, a jet can be added with the switch (Picture 14).

SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(32\)

WATER MAINTENANCE

When filling the massage pool, check the hardness of your water. If your water contains a lot of limescale, add a water softener that protects the pool and pool technique from the limescale.
It is also important to chlorinate water before using the massage pool for the first time. Only use fast-soluble chlorine granulate and not chlorine tablets or liquid chlorine. At the end of the process, adjust the pH value (the value must be between 7.2 and 7.6). Use litmus paper to measure it.

IMPORTANT!
When placing chemicals in the massage pool, turn on all the massage pumps for 10 to 15 minutes to ensure that the agents are evenly moistened in the water.

DRAWING

Switch off the fuse before drawing.
Now you can omit water; you can either install the hose or let it run out.
Unscrew the cover (Picture 16) and rotate the back of the valve to the left to open it (Picture 17). Now the water should drain. For almost complete emptying it is necessary to connect the pump, since the outflow is slightly higher as the lowest point of the massage pool!

Attention!
If you empty the pool before winter time or prepare for the winter, empty the pool to the end so that there is no water left. To ensure complete discharge, remove the connections on the pumps and heating! Rinse the filter too! SANOTECHNIK-SPA08-Outdoor-Swimming-Pools- \(33\)

CLEANING

CLEANING OF THE FRAME
The frame of the pool is made of weather resistant material. Clean it 1-2 times a year or, if necessary, more often.
Do not use aggressive cleaners.

CLEANING THE COVER
Clean the cover with the necessary non-aggressive cleaners, water and a soft cloth. Please remove branches, lists, etc. not to damage the headgear.

CLEANING THE OUTDOORPOOL BASE
Use a soft sponge or cloth to clean the pool. You never use aggressive cleaners or rough objects because you can damage acrylic. The interior loses its brilliance, other injuries can occur and the warranty is no longer valid!

ERRORS

Error Error is shown as Troubleshooting
None of the pumps and heating does not work The display shows E01,

temperature sensor is in short contact or not connected, sensor failure for the water level, the water level is too low!| Check the contacts and, if necessary, replace them.
Nothing appears on the screen| There is nothing visible on the screen,

including steering, settings are not possible.

| Check the connection, possibly replace the screen.
LED lighting doe snot work| LED lighting can not be switched on or works only partially.| Check the left-hand coupling on the control panel housing or Afts around the massage pool.

SANOTECHNIK HANDELSGESELLSCHAFT M.B.H.
Industriestraße 5

SC SANOTECHNIK COM RUMANIEN S.R.L. ROMANIA

  • Tancabesti, DN 1, KM 26,5 Com. Snagov, jud. llfov
  • T : +40 / 21 350 13 43
  • F : +40 / 21 350 13 44
  • E : office@sanotechnik.ro

Sanotechnik Bulgaria EOOD BULGARIA

SANOTECHNIK d.o.o. SLOVENIJA

  • Stritarjeva ulica 24
  • SI-2000 Maribor
  • T: +386 / 2 42 13 350
  • F: +386 / 2 42 13 358
  • E: info@sanotechnik.si

SANOTECHNIK HUNGÁRIA KFT. HUNGARIA

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals