Dolphin DOL1000-MF Keypad User Manual
- June 4, 2024
- DOLPHIN
Table of Contents
DOL1000-MF Keypad
User Manual
DOL1000-MF Keypad
http://uqr.to/dol1000mf-series
Terminal Guide
-
V+/V-
These terminals will supply power to the transmitter. -
RF1
Channel 1 terminal -
NO (Normally open)
Use N.O. for equipment that requires a temporary surge of electricity to activate. Examples, Electric door locks, automated gates, push plates, etc. -
COM
Common ground -
NC (Normally closed)
Use N.C. for equipment that requires a constant flow of electricity to function properly. Examples, Magnetic locks, receivers, etc. -
BATTERY 6VDC
If deciding to power the DOL1000-MF with a battery, then connect the battery to these terminals. -
6-24VAC/DC
If deciding to hardwire the DOL1000-MF directly to a power source, use these terminals. -
Master Reset Button
Holding this button down for 5 seconds reconnecting to its power source will make the keypad beep 3 times. This will indicate that the Master Code has been reset to 1234.
Module Installation
OPTION 1: Installing a Dip Switch Module
IMPORTANT
Be sure to connect the power source to the correct terminals! The battery
terminals and the AC/DC terminals are different.
DIP SWITCHES
-
SOUND
-
LED
-
LIGHTS
-
Not used
-
Not used
-
WIRELESS MODE
a. Switching this dip switch to off will enable the toggle gate feature and switching to the on position will disable the toggle gate feature. Disabling this feature can potentially save battery power in the case that the toggle gate feature has been accidentally activated. Refer to the programming chart for more details about the toggle gate feature. -
Not used
-
Not used
OPTION 2: Installing a 433MHz Module
STEP1: Prepare the 433 MHz module| STEP2: Remove (cut) the battery
connector
---|---
|
STEP 3: Install the 433 MHz Module to the keypad board
IMPORTANT
Be sure to connect the power source to the correct terminals! The battery
terminals and the AC/DC terminals are different.
Any channel can be assigned for devices that connect to normally open/normally
closed.
Programming Guide
NOTE: Default Master Code:
-
Add Access Codes Example:
STEP 1: Press 1 2 3 4
STEP 2: Press 1 #
STEP 3: Enter access code
STEP 4: Press 1 # (multiple beeps confirm)
STEP 5: Press
STEP 6: Test the new access code. (Green light will flash 6 times confirming that the new access code has been accepted.)
STEP 7: Install the module.
STEP 8: Proceed to program the keypad to the receiver.
Use Channel 1 if unsure. The different channels are dependent on the RF terminal used. Any channel can be assigned for devices that connect to normally open/normally closed. -
Remove Access Codes
-
Set Relay Output Time
-
Change Master Code
(Green light will flash confirming that the new access code has been accepted.)
-
Clear All Codes
NOTE: This will clear all data except the Master Code.
Advanced Features
Add Guest Code
The Guest Code is a one-time use access code. Once used, the number will be cleared from memory. 100 Guest Codes are available.
Add Access Toggle Code
NOTE: TOGGLE MODE IS ONLY FOR USE WHEN KEYPAD IS HARD-WIRED.
Entering Access Toggle Code will toggle the keypad to continuously activate.
Entering the code again will toggle the keypad off. Dip switch #6 on the
circuit board needs to be in the off position in order for this mode to work.
Resetting the Keypad and Master Code
Locate the red Master Reset Button on the circuit board.
- Remove the battery or eliminate the power source to the keypad. Wait 30 seconds for the keypad to completely power off.
- Press and hold the Master Reset Button.
- While holding the Button, reconnect the battery or power source to the keypad.
- Continue to hold the Button until the keypad beeps 3 times.
This indicates that the Master Code has been reset to 1234.
Specifications
IP Rating: IP64
Temperature Rating: -40C to 70C / -40F to 158F
Size: 7 1/2 in. x 4 5/8 in. x 3 5/8 in. • Weight: 1 ¾ lbs.
Housing: ABS • Face Plate Material: ABS
Operating Voltage: 6-24 AC/DC
Output relays: 1A
TRANSMITTER SOLUTIONS WARRANTY
The warranty period of the Transmitter Solutions keypad is twenty-four (24)
months. This warranty shall begin on the date the keypad is manufactured.
During the warranty period, the product will be, repaired or replaced (at the
sole discretion of Transmitter Solutions) if the product does not operate
correctly due to a defective component. This warranty does not extend to (a)
the keypad case, which can be damaged by conditions outside the control of
Transmitter Solutions, or (b) the battery life of the keypad. This warranty is
further limited by the following disclaimer of warranty and liability:
EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO
WARRANTIES REGARDING THE GOODS, EXPRESS OR IMPLIED, INCLUDING
WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS,
EXPRESS OR IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM “AS-IS/WHERE-
IS”. TRANSMITTER SOLUTIONS SELLS THE GOODS TO THE BUYER ON THE CONDITION
THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF
THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR
DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
INCLUDING INJURIES TO PERSONS OR PROPERTY, TO BUYER, ITS EMPLOYEES, OR
AGENTS, AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER
SOLUTIONS HARMLESS FROM ANY CLAIMS THE BUYER OR ANY THIRD PARTY MAY HAVE AS A
RESULT OF THE BUYER’S USE OR DISPOSAL OF THE GOODS. BUYER HAS READ THIS
DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.
2480 South 3850
West, Suite B
Salt Lake City, UT 84120
866-975-0101 •
866-975-0404 fax
www.transmittersolutions.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>