Ecosense EcoBlu Digital Range Gas Monitor User Guide
- June 3, 2024
- ECOSENSE
Table of Contents
EcoBlu Digital Range Gas Monitor
User Guide
EcoBlu™ Introduction
Digital Radon Gas Monitor
Fast, accurate results on a display for short-term and long-term radon
monitoring
Our real-time radon detection and monitoring device, EcoBlu™, integrates the
latest patented radon sensor technology. It delivers an easy to use, fast,
highly accurate, compact, and affordable solution for continuous radon
monitoring. EcoBlu™ is a plug-and-play radon detector that provides the first
radon result in minutes, not days. It also gives daily, weekly, monthly, and
yearly average radon levels, and thus peace of mind all year round.
In The Box
EcoBlu™ Set Up Guidelines
- Place EcoBlu at least 20 inches (50 cm) above the floor and from the wall. Do not place EcoBlu close to open windows or vents and keep it away from high heat and high humidity. Install at least 2 feet (61 cm) away from Wi-Fi routers and hotspot devices that may affect electromagnetic interference (EMI) on your device,
- Connect the power adapter to the EcoBlu.
- You will get your first radon reading within 10 minutes of booting up.
EcoBlu™
EcoBlu™ Operation Guideline
Select measurement mode
Real-time mode (R) is set by default. You can Select average radon
measurement mode between real-time (R), daily (D), weekly (W), monthly (M),
long-term monitoring (L) by clicking the M (Monitoring Mode) button on the
back of the device.
R (Real-time monitoring mode): Default
mode when the device is first powered on and radon reading updates every 10
minutes with an hourly moving average. If the device powers off, reading will
be automatically reset.
D (Daily monitoring mode): Radon
reading updates every hour with the last 24 hours of moving average. First
data is available after 24 hours of data points have been collected. If the
device powers off, reading will be automatically reset.
W (Weekly monitoring mode): Radon
reading updates every 24 hours with the last 7 days of moving average. First
data is available after 7 days of data points have been collected. If the
device powers off, reading will be automatically reset.
M (Monthly monitoring mode): Radon
reading updates every 24 hours with the last 30 days of moving average.
First data is available after 30 days of data points have been collected. If
the device powers off, reading will be automatically reset.
L (Long-term monitoring mode): Radon
reading updates every 24 hours with total days averaged since monitoring
began.
First data is available after 24 hours of data points have been collected. If
the device powers off and on, the last reading will be displayed and radon
readings will not be deleted until the device is manually reset.
Change Settings
Measurement units
- You can change the measurement units to Bq/m? or pCi/L by clicking the S (Settings) button on the back of the device.
- Press S button for 3 seconds to enter settings mode, then click M button to select Ba/m? or pCL.
- After selecting the units, press the S button again for 3 seconds to complete the setting.
Dim the LED light
- Press the S button for 3 seconds to enter the setting mode, then click the S button again to select D (Dimming).
- After selecting the dimming mode, click the M button to select dim level from 0 to 4.
- Press the S button again for 3 seconds to complete the setting.
Alarm level threshold
- You can turn on or off the alarm by clicking the S button on the back of the device.
- Press the S button for 3 seconds to enter the settings mode, then click the S button again to select alarm level.
- After selecting the alarm level setting, click the M button to select the desired alarm level.
- From 2.0 pCi/L to 5.0 pCi/L
- From 100 Bq/m? to 400 Bq/m? 4. Press the S button for 3 seconds to complete the setting.
Factory reset
- A factory reset will erase all data from your device and reset device settings to its original system state.
- Press the M button for 10 seconds to enter the factory reset mode.
- A countdown appears: REST 9->8->….. 2->1
LED Display| EcoBlu status| Meaning of status| How to
operate
---|---|---|---
| Ready| Prepare for the first radon reading after turning on| Immediately
when device is
plugged in
R| Real-time monitoring| Hourly moving average (Update every 10
minutes)| Default mode, to change radon monitoring mode, click M button
D| Daily monitoring mode| Last 24 hours of average (Update every hour),
first data available after 24 hrs| To change radon monitoring mode, click M
button
W| Weekly monitoring mode| Last 7 days of average (Update every 24
hours), first data available after 7 days| To change radon monitoring mode,
click V button
M| Monthly monitoring mode| Last 30 days of average (Update every 24
hours), first data available after 30 days| To change radon monitoring mode,
click M button
L| Long-term monitoring mode| Average of total measurements since
monitoring began(Update every 24 hours), first data available after 24
hours| To change radon monitoring mode, click M button
---|---|---|---
Days| Radon measurement period (Days)| Total days of measurement
(Applicable only in LONG-TERM MONITORING mode)| To view measurement periods,
click M button
| Action required| When the detected radon level is above the alarm level
threshold| To change the alarm level threshold, click S button for 3 seconds
| Reset(clear) data| To clear saved long term monitoring data in the device|
Click M button for 10 seconds on the back of the device
| Measurement units – pCi/L| Selected measurement units are pCi/L| To change
the measurement units, click S button for 3 seconds and click M button to
select
| Measurement units – Bq/m3| Selected measurement units are Bq/m3| To change
the measurement units, click S button for 3 seconds and click M button to
select
| Dimmer| Adjust brightness of the LED display| Press and hold the setting S
button for 3 seconds
For more details, please visit us at https://ecosense.io/user-guides
We are happy to help, please visit us at
https://ecosense.io/support
Technical Specifications
Radon Sensor: Pulsed ionization chamber
Radon Sensitivity: 18 CPH (Counts Per Hour) per 1 pCi/L (Picocuries Per Liter)
Radon Accuracy/Precision: < +14% at 10 pCi/L after 10 hours (minimum
uncertainty: + 0.7 pCi/l)
Radon Measurement Rate: Every 10 minutes
Radon Measurement Results: 1 hour / 1 day/ 1 week / 1 month moving averages
Radon Measurement Range: 0.2 ~ 99.9 pCi/L (7~3,700 Bq/m?)
Radon Alarm: Integrated audio alarm (configurable to set radon level)
Radon Level Visual Indicator: LED display
Power Supply: 5V, 1A
Weight: 0.341 Ib (155 g)
Operating Temp Range: 32~104°F (0~40°C)
Learn About Risk From Radon
You can’t see, smell or taste radon, but it could be present at a dangerous
level in your home. Radon is the leading cause of lung cancer deaths among
nonsmokers in America and claims the lives of about 21,000 Americans each
year. In fact, the EPA and the U.S.
Surgeon General urge all Americans to protect their health by testing their
homes, schools and other buildings for radon.
Exposure to radon is a preventable health risk. Testing radon levels in your
home can help prevent unnecessary exposure. Radon gas levels fluctuate by the
hour, day, month, and year. That is why long-term continuous monitoring is
very critical. Just because your radon test results may currently be below
acceptable levels, does not mean that they will always remain at those
levels. If a high radon level is detected in your home, take steps to fix the
problem to protect yourself and your family.
Limited Warranty
Ecosense products are warranted to substantially conform to their product
specifications and against original defects in design, materials, and
workmanship for a period of twelve (12) months, calculated from the later of
the date of purchase or delivery if ordered on the Internet, when used for
normal domestic purposes in accordance with the Ecosense User Guide. Ecosense
Shall not be liable for damages related to failure or loss of data arising
from incorrect operation and handling of the products.
Please see www.ecosense.io/support for
specific warranty and liability information relating to this Product.
Safety and Maintenance
The Ecosense EcoBlu (‘Product or ‘product’ is intended for indoor use only.
Avoid direct exposure to sunlight for long periods of time.
Avoid exposure to direct heat sources. For correct usage, make sure the
Product is operating in the specified temperature range (see technical
specifications in the User Guide or visit
www.ecosense.io).
Exposure to high humidity may permanently alter the product sensitivity or damage the Product. Do not disassemble. If the Product does not work as specified, please contact your local dealer or visit us at www.ecosense.io. Use a dry cloth to clean the Product. Disposal: electronic equipment.
Regulatory Compliance USA
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the Product.
This Product complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This Product may not cause harmful
interference, and (2) this Product must accept any interference received,
including interference that may cause undesired operation.
This Product has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This Product generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this Product does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the Product and receiver.
- Connect the Product into an outlet ona circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
EU Declaration of Conformity
Hereby, Ecosense Inc., 1777 Hamilton Avenue, Suite 2180, San Jose, CA
95125, USA, declares that this Product is following the provisions of CE. The
full text of the EU declaration of conformity is available by contacting
Ecosense support at support@ecosense.io.
Power Supply
The Product (Model EB100) contains a power supply tested according to the
following standards: UL62368-1 (for US adapter), EN62368-1 (for EU adapter)
Model Description
EcoBlu (Model: EB100)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>