Rise F080 Ultra Compact Exterior Rated LED luminaire
FREEDOM TO CREATE™
** Read the following instructions before operating the luminaire.
EcoSense Lighting fixtures must be installed by a qualified electrician.
EcoSense Lighting, Inc. is not responsible if its fixtures are not installed
in accordance with all national and local safety standards.
** Surge Protection Devices with a minimum discharge current rating of
20kA, that meet UL1449, CSA C22.2 No. 269.1, and IEC TR 62066, should be
installed on each branch circuit.
MACRO™ Aiming System
INCLUDED
RISE F080 Installation Guide
Every lighting fixture includes firmware that facilitates electronic dimming
control
*For other RISE Installation Guides visit www.ecosenselighting.com/downloads/rise
OPTIONAL ITEMS
Interchangeable Lens
Color Filter
Snoot/Half Snoot
Canopy/Junction Box Cover
EcoSpec® LDCM 0-10V Module
*For more accessories visit www.ecosenselighting.com/rise
NOTES
Screw Torque Settings:
Screws to replace the Lens and Bezel
Screws for MACRO™ Lock Pan and Tilt
IC Cable Length
EC Cable Length
NPT Fitting Height
Wire Color Description| Hex 2.5 mm; 0.85 Nm ± 0.15 Nm
Hex 4 mm; 12 Nm ± 0.5 Nm
0.48 m (19 in)
3.048 m (10 ft)
12.7 mm (0.5 in)
Brown = Line
Blue = Neutral
Green/Yellow = Ground
---|---
PLAN THE INSTALLATION
Verify the Electrical Plan
Fixture-to-Fixture Runs
UL ONLY| Direct to Junction Box
UL ONLY
---|---
|
CAUTION: Luminaires should not be installed such that they are looked into directly for long periods of time
- Fixtures are UL Listed
** Fixture mounting and wiring to the junction box must be done in accordance with the local code
INSTALL THE FIXTURES
Select Mounting Option
** Ensure power is OFF
Choose the method best suited for mounting surface and installation
application
MOUNT ON A JUNCTION BOX***
UL ONLY
IC – Internal Cable (19 in/48.26 cm Flying Leads)
Optional canopy accessory parts are sold separately
- Choose junction box* type, and secure it to the mounting surface.
- Mount fixture via 1/2 inch NPT fitting and 1/2 inch NPT lock nut to the architectural junction box canopy and seal the screw holes and side gasket using RTV and Seal tape. Run wires through the junction box cover or canopy sealing and gasket ring.
- Create secure wire connections to the main power cables through wire nuts or wiring blocks as per local electrical code. (Refer to images for both flying leads exiting the fixture and external rated cable.)
- Fasten the architectural junction box canopy to the junction box. (For damp or wet locations, use an exterior rated junction box and install it per manufacturer instructions.)
NON-ECOSENSE CANOPY| ECOSENSE CANOPY
Sold Separately
---|---
|
Supplied by others| See specific installation instructions of EcoSense Canopy/Junction Box Cover
MOUNT TO SURFACE
Surface Mount Bracket accessory included with EC versions
EC – Exterior-Rated/External Cable Side Exit and External Cable Bottom Exit
- Fasten the Surface Mount bracket to the base of the fixture using the four M3 screws provided.
- Mount fixture to Surface using two 1/4 inch or M6 flat head screws.
- Create secure wire connections between the EC Cable and the main power cables through wire nuts or wiring blocks as per local electrical code.
- For damp or wet locations, use an exterior-rated junction box and install it per manufacturer instructions.
SURFACE MOUNT | SURFACE MOUNT |
---|---|
MOUNT TO POLE OR POST
Post Cap accessories are sold separately
- Fasten the Pole Cap accessory to the fixture via 1/2 inch NPT fitting.
- For the internal cable option, feed cable through Pole or Post to termination location.
- For external cable option, route cable to Junction Box*.
- Mount fixture with pole cap accessory to Pole or Post and secure via two set screws.
- Create secure wire connections between the EC Cable and the main power cables through wire nuts or wiring blocks as per local electrical code.
- For damp or wet locations: For UL, use an exterior-rated junction box and install it per manufacturer instructions. For CE use recommended junction box is WISKA COMBI 308.
INTERNAL CABLE
For Sealed Pole/Post Only| EXTERNAL CABLE
---|---
*Supplied by others|
RISE F080 INTERCHANGEABLE LENS
- Loosen the two screws on the Back Bezel with a 2.5 mm hex driver or key until the Front Bezel comes off.
- Switch the clips to the open position. Replace the old lens and install the new lens. Refer to the lens installation instructions for specifics. Switch the clips to the closed position.
- Attach the clips to the Front Bezel with the screws. Make sure the clips sit flush with Front Bezel. Tighten the rear screws to ensure a proper seal against the tertiary lens. Recommended Torque: 0.85 ± 0.15Nm.
|
---|---
RISE F080 SNOOTS
- Loosen the two screws on the Back Bezel with a 2.5 mm hex driver orkey until the Front Bezel comes off.
- Switch the clips to the open position. Replace the old lens and install the new lens. Refer to the lens installation instructions for specifics. Switch the clips to the closed position.
- Attach the clips to the Front Bezel with the screws. Make sure the clips are flush with Front Bezel. Tighten the rear screws to ensure a proper seal against the tertiary lens. Recommended Torque: 0.85 ± 0.15 Nm.
FULL SNOOT | HALF SNOOT |
---|---|
INSTALLATION CONSIDERATIONS
POWER CONSUMPTION | 4 W / 7.5 W / 11.5 W |
---|---|
OPERATING TEMPERATURE | –40°C to 50°C |
OPERATING VOLTAGE | 120–277 VAC, 50–60 Hz |
OPERATING AMPERAGE | Vea las caracteristicas eléctricas en la etiqueta del |
producto
WEIGHT| 1.1 lbs ; (0.5 kg)
DIMENSIONS| W 2.49” x H 8.13” x L 2.49” ; (63.33 mm x 206.45 mm x 63.33 mm)
*NOM Only| Refer to the electrical rating marked on the luminaire.
- Read and understand the installation instructions before attempting to install or use the fixture.
- Only use fixtures with voltage for which it is rated. Do not exceed the specified voltage and current input.
- Do not use fixtures if the housing, lens, or power cable are damaged.
- Ensure that the main power supply is off before installing or wiring a fixture.
- Hazardous live parts shall not be accessible after installation, and it is the installer’s responsibility to ensure that the installation/connections are in compliance with national and local electrical codes and regulations.
- The wire connection method shall be determined by local electrical codes and regulations, typically using either wire nuts or screw terminal blocks.
- Possibly hazardous optical radiation emitted from this product.
- Polycarbonate Chemical Warning: Please contact an EcoSense sales representative for a complete list of chemicals that can cause damage to polycarbonate lenses and silicone gaskets. EcoSense must not be held responsible for damage to, or failure of, fixtures where any of these, or chemicals of similar nature and makeup, are applied intentionally or inadvertently to EcoSense’s fixtures.
- Earth leakage Statement: Please contact an EcoSense factory representative for full information on the earth leakage properties of fixtures when installed according to all local electrical codes and proper installation techniques.
- EcoSense Inrush Current Statement: Please contact an EcoSense Lighting sales representative for a complete list of Inrush Current Peak (A) at specific product Voltage, and Inrush Current Duration/Width (ms), for each EcoSense product.
- The external flexible cable of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similarly qualified person.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or experienced radio/TV technician for help.
Modifications:
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
ECOSENSE LIGHTING INC.
837 NORTH SPRING STREET SUITE 103
LOS ANGELES, CA 90012
P • 310.496.6255
F • 310.496.6256
T • 855.632.6736
855.6.ECOSEN
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
VISIT ECOSENSELIGHTING.COM FOR THE MOST CURRENT
SPECIFICATIONS.
FOR A LIST OF PATENTS VISIT ECOSENSELIGHTING.COM/IP-
PORTFOLIO/
©2019 ECOSENSE LIGHTING INC. ALL RIGHTS RESERVED. ECOSENSE, THE
ECO SENSE LOGO, TRoV, TROV, AND ECOSPEC ARE REGISTERED TRADEMARKS
OF ECOSENSE LIGHTING INC.
RISE™, SLIM COVE™, FREEDOM TO CREATE™, MACRO™, AND FLIP-TO-FLAT™ ARE
TRADEMARKS OF ECOSENSE LIGHTING INC.