Specifications

  • Model: AD1400B-AD900B-AD900C
  • Diameter: 1170mm, 800mm, 800mm
  • Maximum Speed: 500 r/min, 1200 r/min, 920 r/min
  • Maximum Power Consumption: 1.40 kW, 0.99 kW, 0.62 kW
  • Maximum Thrust: 105 N, 56 N, 36 N

Product Usage Instructions

General Warnings
Make sure to follow all safety precautions and guidelines during installation and use of the air circulator.

Installation

  1. Ensure the air circulator is installed at a height not less than 2.7m from the floor.
  2. Maintain a minimum distance of 1.5m between the air circulator and any walls/obstacles, as well as between multiple air circulators.

Components

  • Fan Blade (Girante): 1 piece
  • Casing (Carcassa): 1 piece
  • Motor: 1 piece
  • Bolt M10 (Golfare M10): 4 pieces
  • Washer (Rondella): 8 pieces
  • Screw M10x25 (Vite M10x25): 4 pieces

Specific Instructions for Installation
Installers are responsible for the correct and safe installation of the air circulator according to local regulations. Follow these specific instructions:

Suspension Installation
Use the provided eye bolts and distribute the load evenly. Avoid uncontrolled rotations and use appropriate chains or ropes. Minimum suspension requirements are a working load of 2 kN and a breaking load of 5 kN.

Fixed Installation
Use expansion anchors on concrete structures or M-threaded bolts on metal or wooden structures using the available hole diameters at the mounting points.

Frequently Asked Questions (FAQ)

  • Q: What are the maximum power consumption and thrust values for each model?

    • A: The AD1400B has a max power consumption of 1.40 kW and thrust of 105 N, the AD900B has a max power consumption of 0.99 kW and thrust of 56 N, and the AD900C has a max power consumption of 0.62 kW and thrust of 36 N.
  • Q: What is the minimum height requirement for installation?

    • A: The air circulator must be installed at a height not less than 2.7m from the floor.
  • Q: How many eye bolts and screws are included in the package?

    • A: The package includes 4 eye bolts (Golfare M10) and 4 screws (Vite M10x25).

Translated from Original Instructions

AD1400B-AD900B-AD900C High volume circulation fans

GENERAL INFORMATION
Carefully read the instructions contained in this manual.
This Specific Manual MUST be read in conjunction with the “Installation, Operation and Maintained General Manual”. Note: store the manual for future reference. We reserve the right to improve and make changes to the manual, products and accessories without any obligation to update previous productions and manuals.
The installation, electric wiring and service of the unit must be performed by an authorized installer and in accordance with local rules and regulations.

PRECAUTIONS
In addition to the precautions indicated in the “Installation, Operation and Maintenance General Manual” special attention should be paid to the following warning notes
The fan must be installed at a height of not less than 2.7m from the floor below. Installation at a lower height is considered “improper use”. In case of “improper use” the manufacturer declines all responsibility for any damage that may be caused to persons or property, and any warranty will be considered invalid.

RECOMMENDED BOLT TORQUE FOR COARSE THREADED METRIC STEEL BOLTS TE-TCEI GRADE 8.

Dimensioni M6 M8 M10 M12 M14 M16
Nm 9,5 23 46 79 127 198

Table 1 Use the values shown in the table to tighten all the screws.

  • Check/inspect and eventually retighten all the fixing annually.
  • Fans should not operate in case of strong wind (≥ 6m/s).

The installer and the building owner are responsible to ensure the safety of the fan mounting system and that the fan installation is correct, in compliance with any national and local regulations.

TYPE AXIAL FANS
Ceiling fan with EC brushless motor suitable for wall installation or suspended at ceiling, designed for industrial, civil and zootechnical applications, where high performances are required.

MAIN FEATURES

  • Strong and robust design and manufacturing (galvanised steel)
  • Simplified electrical wiring connection
  • Max temperature +50°C
  • Gearless for silent operation and maintenance free
  • B version: high efficient one-phase EC Brushless motor, 220/277Vac, 50/60Hz, IP55, with integrated electronic system and EMC filters, speed controllable and suitable for S1 continuous service
  • C version: three-phase AC Motor, 220/277Vac, TEFC, 50Hz, IP55, suitable for S1 continuous service

DATA

| |  max|  max|  max| max AMCA 230-15|  max AMCA 230-99
---|---|---|---|---|---|---
| | r/min| kW| N| cfm| m3/h| SPI(3)

W/(m3/s)

| cfm| m3/h| SPI(3)

W/(m3/s)

AD1400B (1)| 1170| 500| 1,40| 105| 20551| 34917| 144,3| 29064| 49380| 102,1
AD900B (1)| 800| 1200| 0,99| 56| 10300| 17500| 203,7| 14567| 24749| 144,0
AD900C (2)| 800| 920| 0,62| 36| 8240| 14000| 159,4| 11653| 19799| 112,7

  1. Data @230Vac, 50 Hz
  2. Data @400Vac, 50 Hz
  3. Max. absorbed power / max. airflow

DIMENSIONS AND CLEARANCES

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image \(1\)

Modello A B C D E F G I h (min)* Peso
mm mm mm mm mm mm mm mm mm kg
AD1400B 1382 1382 1189 1200 210 270 208 478 2700 52
AD900B 951 951 819 780 210 270 161 431 2700 40
AD900C 951 951 819 780 210 270 132 402 2700 36

ATTENTION: The fan must be installed at a height of not less than 2.7m from the floor below
ATTENTION: A minimum air space in front and behind the fan of 1.5m is required (from wall or similar obstacle and between  each fan in case of in- line installation of multiple units)

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image \(2\)

COMPONENTS

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image \(3\)

Pos. Description Q.tà
1 GIRANTE 1
2 CARCASSA 1
3 MOTORE 1
4 GOLFARE M10 4
5 RONDELLA 8
6 VITE M10x25 4

INSTALLATION

ATTENTION: Make sure that the main supply to the unit is disconnected before performing any installation, service, maintenance or electrical work!
The fan must be installed at a height of not less than 2.7m from the floor below.
The fan must be installed with sufficient surrounding space for assembly/disassembly, cleaning and maintenance.

ATTENTION: the installer and the building owner are responsible to ensure the safety of the fan mounting system and that the fan installation is correct, in compliance with any national and local regulations.

The fan can be wall installed or suspended at ceiling.
For suspended installation pay attention to the following indications.

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image \(4\)

Eyebolts are provided for units which are to be suspended, as per Fig .I: the weight has to be evenly distributed.
Avoid spinning of the unit out of control. Provide suitable chains or ropes. It is recommended to use a suspension means with a workload of at least 2 kN and breaking load of at least 5 kN.

In the case of fixed installation, provide a mechanical expansion anchor intended for use in solid concrete, or metric screws for  use in metal or wooden structures using the entire available diameter of the holes in the fixing points.

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image \(5\)

The suspension chains must be installed at an angle of approx. 45° as shown in Fig. II-A. The fan will naturally tilt back under operation. If very long chains are used to suspend the unit, a pendulum effect may occur. In this case, additional chains should be attached to the bottom rear corners to prevent this effect.

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image \(6\)

If the fan is tilted, the chains must be attached to the eyebolts previously mounted on the fixing points.

ELECTRIC WIRING DIAGRAM
Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintained or electrical work!The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in accordance with local rules and regulations.

Fan must be earthed.

CTRL-A (accessory on request)

CTRL-A2 (accessory on request)

CONTROL WITH EXTERNAL POTENTIOMETER (not supplied)

CTRL-XWS (accessory on request)

aerauliqa-AD-Serie--High-Volume-Axia--Fans-image
\(13\)

CTRL-XTHI (accessory on request)

AD900C
aerauliqa-AD-Serie--High-Volume-Axia--Fans-image
\(17\)

CLEANING
ATTENTION Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or electrical work!
Carry out cleaning operations periodically. The unit (IP55) can be washed with a low-pressure water jet to avoid damaging the impeller.

DECLARATION OF CONFORMITY AND INCORPORATION

UE DECLARATION OF CONFORMITY/INCORPORATION
Manufacturer

AERAULIQA SRL
Via Mario Calderara 39/41 – 25018 Montichiari (BS) – ITALY

UE DECLARATION OF CONFORMITY

We herewith declare that the following range:

AD axial fans

BRAND : AERAULIQA
MODELS
AD1400A, AD1400B
AD900B, AD900C
on the basis of its design and construction as partly completed machines brought onto the market, is designed in compliance within relevant health and safety requirements of the following Directives:

2014/35/UE – Low Voltage Directive (LVD)
2014/30/UE – Electromagnetic Compatibility (EMC) 2
009/125/EC – Energy Related Products (ErP)

in the event that alterations are made to the machinery without prior consent with the manufacturer, this declaration becomes invalid.
This declaration is issued under the sole responsibility of the manufacturer.

UE DECLARATION OF INCORPORATION
In accordance with the Machinery Directive 2006/42/EC.

We herewith declare that the following range

AD axial fans

BRAND: AERAULIQA
MODELS
AD1400A, AD1400B
AD900B, AD900C

on the basis of its design and construction of partly completed machines, is designed in compliance with the Essential Health and Safety Requirements (EHSRs) of ANNEX l, sections 1.1.2 (Safety integration), 1.1.5 (Handling), 1.4.1 (Protective devices), 1.5.1 (Electricity) of EC Machinery Directive 2006/42/EC.

The machinery is incomplete and must not be put into service until such time as the machinery which is partly complete is to be incorporated and has been assessed and declared in conformity with the provisions of the Machinery Directive 2006/42/EC.

We undertake to transmit, upon a reasoned request by appropriate national authorities, relevant information on the partly completed machinery identified above.

During installation, it is recommended to write the serial number of the unit in this manual and keep it safe for maintenance service.

SERIAL NUMBER

Aerauliqa S.r.l. – via Mario Calderara 39/41, 25018 Montichiari (Bs)
C.F. e P.IVA/VAT 03369930981 – REA BS-528635 –

Aerauliqa S.r.l. reserves the right to modify/make improvements to products and/or this instruction manual at any time and without prior notice.

005998 – 01 – 07 24

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

aerauliqa User Manuals

Related Manuals