aerauliqa AD1400B High Flow Aair Circulator
Specifications
- Model: AD1400B
- Type: High-flow air circulator
- Power Supply: 400Vac, 50Hz
- Maximum Fan Diameter: 1170mm
- Maximum Speed: 500 rpm
- Maximum Power Consumption: 1.40 kW
- Maximum Thrust: 105N
- Maximum Airflow (AMCA 230-15): 20551 cfm / 34917 m3/h
- SPI (Specific Power Input) at Max Airflow: 144.3 W/(m3/s)
- Maximum Airflow (AMCA 230-99): 29064 cfm / 49380 m3/h
- SPI (Specific Power Input) at Max Airflow: 102.1 W/(m3/s)
Product Usage Instructions
- General warnings
- Read the instructions in the manual carefully. This specific manual should be read along with the General Installation, Use, and Maintenance Manual. Keep the manual for future reference. The installation, electrical connections, and maintenance should be done by a qualified and authorized installer following local regulations.
- Specific Warnings
- Use the specified torque values for tightening all bolts. The installer and the structure owner are responsible for the correct and safe installation of the fan according to local regulations.
- Type of Fan
- The AD1400B is an axial fan with a brushless EC motor designed for industrial, civil, and zootechnical applications requiring high performance.
- Main Features
- Aerodynamic profile design
- Installation Details
- For fixed installation, use expansion anchors on concrete structures or pass-through metric screws on metal or wooden structures, utilizing the entire diameter of the prepared holes for mounting.
FAQs
- Q: What is the recommended minimum height for installing the fan?
- A: The fan should be installed at a height not less than 2.7m from the floor.
- Q: What is the minimum distance required between the fan and any walls/obstacles?
- A: A minimum distance of 1.5m is recommended between the fan and any walls or obstacles.
GENERAL INFORMATION
- Carefully read the instructions contained in this manual.
- This Specific Manual MUST be read in conjunction with the “Installation, Operation and Maintenance General Manual”.
- Note: store the manual for future reference. We reserve the right to improve and make changes to the manual, products, and accessories without any obligation to update previous productions and manuals.
- The installation and service of the unit and complete ventilation system must be performed by an authorized installer and per local rules and regulations.
PRECAUTIONS
In addition to the precautions indicated in the “Installation, Operation and Maintenance General Manual” special attention should be paid to the following warning notes:
- The fan must be installed at a height of not less than 2.7m from the floor below.
- Installation at a lower height is considered “improper use”.
- In case of “improper use,” the manufacturer declines all responsibility for any damage that may be caused to persons or property, and any warranty will be considered invalid.
RECOMMENDED BOLT TORQUE FOR COARSE THREADED METRIC STEEL BOLTS TE-TCEI GRADE 8.
Dimensions | M6 | M8 | M10 | M12 | M14 | M16 |
---|---|---|---|---|---|---|
Nm | 9,5 | 23 | 46 | 79 | 127 | 198 |
Table 1 Use the values shown in the table to tighten all the screws.
- Check/inspect and eventually retighten all the fixing annually.
- Fans should not operate in case of strong wind (≥ 6m/s).
The installer and the building owner are responsible for ensuring the safety of the fan mounting system and that the fan installation is correct and in compliance with any national and local regulations.
TYPE
- Ceiling fan with EC brushless motor suitable for wall installation or suspended at ceiling, designed for industrial, civil, and zootechnical applications, where high performances are required.
MAIN FEATURES
- EC Brushless motor 220-277 Vac, 1ph, 50/60Hz, IP55
- Max temperature +50°C
- Speed controllable
- Suitable for S1 continuous service
- Embedded electronic system
- Gearless for silent operation and maintenance-free
- Simplified electrical wiring connection: pre-wired cables
- Robust design and manufacturing (galvanized steel)
- High-efficient unit (energy-saving EC motor and airfoil impeller)
DATA @400Vac, 50Hz
Model
| Fan diam.| Max speed rotation| Max absorbed power| Max Thrust| Max airflow
AMCA 230-15| Max airflow AMCA 230-99
---|---|---|---|---|---|---
| | r/min| kW| N| cfm| m3/h| SPI(1)
W/(m3/s)
| cfm| m3/h| SPI(1) W/(m3/s)
AD1400B| 1170| 500| 1,40| 105| 20551| 34917| 144,3| 29064| 49380| 102,1
(1) max. absorbed power/max. airflow
DIMENSIONS AND CLEARANCES
Model | A | B | C | D | E | F | G | I | h (min)* | Weight |
---|---|---|---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | mm | mm | mm | mm | kg | |
AD1400B | 1382 | 1382 | 1189 | 1200 | 210 | 270 | 208 | 478 | 2700 | 52 |
ATTENTION: The fan must be installed at a height of not less than 2.7m
from the floor below
ATTENTION: A minimum air space in front and behind the fan of 1.5m is
required (from the wall or similar obstacle and between each fan in case of
in-line installation of multiple units)
COMPONENTS
Pos. | Description | Q.ty |
---|---|---|
1 | Impeller | 1 |
2 | Casing | 1 |
3 | Motor | 1 |
INSTALLATION
- ATTENTION Make sure that the main supply to the unit is disconnected before performing any installation, service, maintenance, or electrical work!
- The fan must be installed at a height of not less than 2.7m from the floor below.
- The fan must be installed with sufficient surrounding space for assembly/disassembly, cleaning, and maintenance.
- The fan can be wall-installed or suspended at the ceiling.
- ATTENTION: For suspended installation pay attention to the following indications.
- Eyebolts are provided for units that are to be suspended, as per Fig.1: the weight has to be evenly distributed.
- Avoid spinning the unit out of control. Provide suitable chains or ropes. It is recommended to use a suspension means with a workload of at least 2 kN and a breaking load of at least 5 kN.
- In the case of fixed installation, provide a mechanical expansion anchor intended for use in solid concrete, or metric screws for use in metal or wooden structures using the entire available diameter of the holes in the fixing points.
- The suspension chains must be installed at an angle of approx. 45° as shown in Fig. I-A. The fan will naturally tilt back under operation. If very long chains are used to suspend the unit, a pendulum effect may occur.
- In this case, additional chains should be attached to the bottom rear corners to prevent this effect.
- If the fan is tilted, the chains must be attached to the eyebolts previously mounted on the fixing points.
WIRING DIAGRAM
- Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or electrical work!
- The installation and service of the unit and complete ventilation system must be performed by an authorized installer and under local rules and regulations.
- Fan must be earthed.
CTRL-A (accessory on request)
CTRL-A2 (accessory on request)
CONTROL WITH EXTERNAL POTENTIOMETER (not supplied)
CTRL-XWS (accessory on request)
CTRL-XTHI (accessory on request)
DECLARATION OF CONFORMITY AND INCORPORATION
UE DECLARATION OF CONFORMITY/INCORPORATION
- Manufacturer: AERAULIQA SRL Via Mario Calderara 39/41 – 25018 Montichiari (BS) – ITALY
UE DECLARATION OF CONFORMITY
- We herewith declare that the following range: AD axial fans
- BRAND: AERAULIQA
- MODELS: AD1400A, AD1400B
Based on its design and construction as partly completed machines brought onto the market, is designed in compliance with the relevant health and safety requirements of the following Directives:
- 2014/35/UE – Low Voltage Directive (LVD)
- 2014/30/UE – Electromagnetic Compatibility (EMC)
- 2009/125/EC – Energy Related Products (ErP)
- If alterations are made to the machinery without prior consent from the manufacturer, this declaration becomes invalid.
- This declaration is issued under the sole responsibility of the manufacturer.
UE DECLARATION OF INCORPORATION
- Following the Machinery Directive 2006/42/EC.
- We herewith declare that the following range: AD axial fans
- BRAND: AERAULIQA
- MODELS: AD1400A, AD1400B
- Based on its design and construction of partly completed machines, is designed in compliance with the Essential Health and Safety Requirements (EHSRs) of ANNEX l, sections 1.1.2 (Safety integration), 1.1.5 (Handling), 1.4.1 (Protective devices), 1.5.1 (Electricity) of EC Machinery Directive 2006/42/EC.
- The machinery is incomplete and must not be put into service until the machinery which is partly complete is to be incorporated and has been assessed and declared in conformity with the provisions of the Machinery Directive 2006/42/EC.
- We undertake to transmit, upon a reasoned request by appropriate national authorities, relevant information on the partly completed machinery identified above.
- During installation, it is recommended to write the serial number of the unit in this manual and keep it safe for maintenance service.
CONTACT
- Sede operativa/Warehouse-Offices: via Mario Calderara 39/41, 25018 Montichiari
- Tel: +39 030 674681
- Fax: +39 030 6872149
- www.aerauliqa.it
- www.aerauliqa.com
- info@aerauliqa.it
- Aerauliqa S.r.l. reserves the right to modify/make improvements to products and/or this instruction manual at any time and without prior notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>