Aerauliqa Quantum NEXT Single Alternate Flow Decentralized Residential
Heat Recovery Unit
Installation manual Quantum NEXT
Read this manual carefully before using the product and keep it in a safe
place for reference.
This product was constructed up to standard and in compliance with regulations
relating to electrical equipment and must be installed by technically
qualified personnel. The manufacturer assumes no responsibility for damage to
persons or property resulting from failure to observe the regulations
contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
- The device should not be used for applications other than those specified in this manual.
- After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small children or people with disabilities.
- Do not touch the appliance with wet or damp hands/feet.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.
- If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use original spare parts only for repairs.
- The electrical system to which the device is connected must comply with regulations.
- Before connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
- The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from any type of combustion unit. It must expel air outside via its own special duct.
- Operating temperature: -20°C up to +50°C.
- The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
- Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
- Do not immerse the device or its parts in water or other liquids.
- Turn off the main switch whenever a malfunction is detected or when cleaning.
- For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Do not obstruct the fan or exhaust grille to ensure optimum air passage.
- Ensure adequate air return/discharge into/from the room in compliance with existing regulations in order to ensure proper device operation.
- If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.
- Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger (test probe “B” of the norm EN61032) in compliance with the current safety regulations.
INTRODUCTION
Quantum NEXT is a single alternate flow decentralized (single point)
residential heat recovery unit, also called a «push&pull» unit, designed to
ensure adequate ventilation in enclosed environments without energy losses.
It is recommended that two units are installed in a pair: when one unit is
pulling, the other is pushing.
The pair of units can be installed in the same room or in different rooms
(i.e. living room and bedroom). The unit is suitable for installation on an
outside wall.
The unit should operate continuously, and only stopped for maintenance or
service.
When heat exchange is not useful (for example in mid-seasons when indoor and
outdoor temperatures are similar), or when heat exchange is not recommended
(for example with the option “summer free cooling”), it is recommended to set
the unit in “extract-only” or “intake-only” mode and NOT to switch it off.
TECHNICAL SPECIFICATIONS
- Design front cover (A) removable for cleaning without the use of tools.
- Inner ventilation unit (B) and wall support base (D) made of high quality, impact, and UV-resistant ABS, color RAL 9010.
- Integrated multi-color led (C) to obtain visual feedback of the unit status.
- Smart humidity control.
- Integral temperature sensor for the automatic management of the inversion time (comfort mode).
- Automatic anti-frost protection to prevent frost from building up on the heat exchanger.
- The wall support base (D) is provided with a magnet “coupling/uncoupling” system which allows the ventilation unit to be removed from its base during maintenance.
- Back-up touch button (J) at the side of the ventilation unit.
- Unique design winglet-type impeller, providing enhanced aerodynamic properties, low noise, and increased efficiency.
- High efficient reversible EC motor with integral thermal protection, mounted on sealed for life high-quality ball bearings. Designed for continuous reversible running.
- Telescopic pipe (F) is adaptable to the wall thickness.
- Antimortar cap designed to be used also as a template during the installation of the wall support base.
- Regenerative heat exchanger with ceramic core (G) with high thermal efficiency, equipped with washable anti-dust filters (H).
- External grille (I) made of high quality, impact, and UV-resistant ABS, color RAL 9010, with anti-insect net and water drip guard.
- Infra-red remote controller with touch technology, LCD display, and wall base supplied as standard. Made from ABS, RAL 9010.
- The unit is double insulated: no earth connection is required.
- No need of a condensation drainage system.
- IPX4 degree of protection.
- Power supply 220-240V~ 50Hz.
**OPERATION
**
The unit is supplied with an infrared remote controller (K) as standard, as
well as its support base (L) which can be wall-mounted. A magnet keeps the
controller attached to the base.
The controller is equipped with an LCD display to visualize the setting to be
transferred to the unit; anytime a touch button is pressed, the setting shown
on the LCD display is transferred to the unit. The IR receiver is placed on
the left side of the ventilation unit (E): it is recommended to point the
controller towards the receiver when any setting needs to be transferred.
One remote controller can control more units.
To activate the remote controller it is necessary to insert two AAA-type
batteries (not supplied).
VENTILATION UNIT
When switched on the unit emits a long acoustic signal.
Through the IR controller, the following functionalities can be
activated/deactivated. When one set is transferred to the unit, a short
acoustic signal is emitted and green led flashes.
BACK UP BUTTON
In case the remote controller gets lost or the batteries are dead, ON and OFF
position can be selected from the on board touch button (J), pressing the
button for at least 3 seconds.
SYNCHRONISATION OF A NUMBER OF UNITS
It is possible to synchronize up to 10 units contemporaneously, through wire
(2 pole twisted pair type, max 30m length) so to have mode and inversion time-
synchronized. When the unit is switched on for the first time, the rotation
direction of each unit (clockwise or anti-clockwise) is automatically
established. Other functionalities like speed, smart humidity control and
boost, continue to be controlled independently on each single unit.
Wiring diagram as per fig. 16B.
MAINTENANCE
Maintenance can be carried out by the user as shown in figures 49-65.
TROUBLESHOOTING
DISPOSAL AND RECYCLING
Information on disposal of units at the end of life.
This product complies with EU Directive 2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must be
collected separately from other waste at the end of its life. The user must,
therefore, dispose of the product in question at suitable electronic and
electro-technical waste disposal collection centres, or else send the product
back to the retailer when purchasing a new, equivalent type device.
Separate collection of decommissioned equipment for recycling, treatment and
environmentally compatible disposal helps to prevent negative effects on the
environment and on health and promotes the recycling of the materials that
make up the equipment.
Improper disposal of the product by the user may result in administrative
sanctions as provided by law.