Read this manual carefully before using the product and keep it in a safe place for reference.
This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this booklet.

PRECAUTIONS FOR INSTALLATION, USE, AND MAINTENANCE

  • The device should not be used for applications other than those specified in this manual.

  • After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small
    children or people with disabilities.

  • Do not touch the appliance with wet or damp hands/feet.

  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  • Do not use the product in the presence of inflammable vapors, such as alcohol, insecticides, gasoline, etc.

  • If any abnormalities in operation are detected, disconnect the device from the main supply and contact a qualified technician immediately. Use original spare parts only for repairs.

  • The electrical system to which the device is connected must comply with regulations.

  • Before connecting the product to the power supply or the power outlet, ensure that:
    – the data plate (voltage and frequency) correspond to those of the electrical mains
    – the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.

  • The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from any type of combustion
    unit. It must expel air outside via its own special duct.

  • Operating temperature: 0°C up to +50°C.

  • The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.

  • Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).

  • Do not immerse the device or its parts in water or other liquids.

  • Turn off the main switch whenever a malfunction is detected or when cleaning.

  • For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.

  • Do not obstruct the fan or exhaust grille to ensure optimum air passage.

  • Ensure adequate air return into the room in compliance with existing regulations in order to ensure proper device operation.

  • If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove, etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion, and proper equipment operation.

  • Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger (test probe “B” of the norm EN61032) in
    compliance with the current safety regulations.

  • Ceiling installation
    In order to guarantee the IPX4 degree of protection against moisture in the case of ceiling installation, use the appropriate ceiling mount kit, which is not included. Use only the rear entry hole for supply cables. If there is a possibility of condensation along the air discharge duct, provide a drainage system to prevent condensation from discharging into the environment through the fan.
    Attention: do not mount the product on the ceiling without this kit.

  • Window installation
    In the case of window installation, it is necessary to use the appropriate window kit, which is not included.
    Attention: do not mount the product on the window without this kit.

INTRODUCTION

Quantum AX is a decentralized mechanical ventilation unit designed to ensure air extraction in small/medium-sized rooms.
Suitable for air discharge directly to the outside or in the presence of a short ducted system. Wall, ceiling, or window installation (fig. 1).

TECHNICAL SPECIFICATIONS

  • Material: High quality, impact, and UV-resistant ABS color RAL 9010.
  • Design front covers removable for cleaning without the use of tools.
  • Rear reinforcement ring to prevent spigot deformation during installation.
  • High efficiency aerodynamic fan with “winglet” blades to optimize quietness and efficiency.
  • Single-phase EC Brushless motor with integral thermal protection.
  • Motor mounted on high-quality ball bearings.
  • The fan is double insulated: no earth connection is required.
  • Trickle speed selectable during installation.
  • Option to boost from trickle (or from off) through LS connection.
  • Installation type selection available (through wall or ducted).
  • IPX4 degree of protection.
  • Power supply 220-240V~ 50Hz.

VERSIONS
BASIC
The fan runs continuously at selected trickle speed (set by the jumper switch combination fig. 15) and can be boosted with a dedicated ON/OFF switch (or PIR, CO2…sensor)  or with a light switch (fig. 13A). Trickle speed can be set to off (fig. 15).
WITH HUMIDISTAT/TIMER
The fan is equipped with a humidity sensor, whose threshold is adjustable from 50% to 95% Relative Humidity via dedicated trimmer, and with a timer which is adjustable from  0 to approx. 30 minutes via dedicated trimmer (fig. 14B).
The fan runs continuously at selected trickle speed (set by the jumper switch combination fig. 15), increases its speed in case the percentage of Relative Humidity exceeds the settable threshold, and can anyway be boosted with a dedicated ON/OFF switch (or PIR, CO2…sensor) or with a light switch (fig. 13B). Trickle speed can be set to off (fig. 15).
To deactivate the humidistat function, turn the trimmer HY completely clockwise.
Automatic humidistat operation: when the percentage of Relative Humidity exceeds the settable threshold, the fan speed automatically increases to “comfort boost” speed,  (intermediate between the selected trickle speed and the boost speed). When the percentage of Relative Humidity goes below the threshold, the fan continues to function at  “comfort boost” speed for a factory set period of time then returns to selected trickle speed.
Operation with external switch: (fig. 13B). When the external switch is turned on, the fan is boosted. After the external switch is turned off, the fan continues to run at boost speed for a settable period of time, then it returns to selected trickle speed (or to “comfort boost” speed in case automatic humidistat operation is on).
The front cover LED indicates when the external switch is on.
The over-run timer function is activated only if the external switch has been on for at least 60 seconds.

INSTALLATION TYPESETTING

Installation type can be selected using JUMPER 1 between the following options: through a wall or ducted (fig. 15).

TRICKLE SPEED SETTING

Trickle speed can be selected using JUMPER (fig. 15).

DISPOSAL AND RECYCLING

Information on disposal of units at the end of life.
This product complies with EU Directive 2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centers, or else send the product back to the retailer when purchasing a new, equivalent type device. Separate collection of decommissioned equipment for recycling, treatment, and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment. Improper disposal of the product by the user may result in administrative sanctions as provided by law.

INSTALLATION

perimetrical exhausting pannello ceiling (accessory on demand)
window (kit on demand) direct exhausting short ducting

MONTAGE AND WIRING DIAGRAM

Quantum AX 100


JUMPER| INSTALLAZIONE
INSTALLATION| PORTATA
AIRFLOW
1| 2| 3
| | | espulsione diretta / through wall| OFF
| | ✓| espulsione diretta I through wall| 21 m3Ih
| ✓| | espulsione diretta I through wall| 29m31h
| ✓| ✓| espulsione diretta I through wall| 47m31h
✓| | | canalization I in room| OFF
✓| | ✓| canalizzato / in room| 21m31h
✓| ✓| | canalizzato I in room| 29m31h
✓| ✓| ✓| canalizzato / in room| 47m31h (default)

Quantum AX 150


JUMPER

|

INSTALLAZIONE
INSTALLATION

|

PORTATA
AIRFLOW

1| 2| 3
| | | espulsione diretta / through wall| 22m31h
| | ✓| espulsione diretta / through wall| 29m31h
| ✓| | espulsione diretta / through wall| 47m31h
| ✓| ✓| espulsione diretta / through wall| 54m31h
✓| | | espulsione diretta / through wall| 61 m3/h
✓| | ✓| espulsione diretta / through wall| 76m3/h
✓| ✓| | espulsione diretta / through wall| 90m3/h
✓| ✓| ✓| espulsione diretta / through wall| 104m3/h (default)

PULIZIA – MAINTENANCE

ErP Directive – Regulations 1253/2014 – 1254/2014

a)  Mark AERAULIQA
b)  Model Quantum AX 100
c) SEC class E
c1) SEC warm climates kWh/m2.a -5,4
c2) SEC average climates kWh/m2.a -13
c3) SEC cold climates kWhhT9.a 4
Energy label No
d) Unit typology Residential – unidirectional
e) Type of drive multi-speed drive
f) Type of Heat Recovery System absent
g) Thermal efficiency of heat recovery % N/A
h) Maximum flow rate m3/h 83
i) Electric power input at a maximum flow rate w 2,6
j) Sound power level (LWA) dBA 44
k) Reference flow rate m3/h 61
l)  Reference pressure difference Pa 10
m) Spedfic power input (SPI) W/m3/h 0,028
n1) Control factors 1
n2) Control typology Manual control
--- --- --- ---
o1) Maximum internal leakage rat % N/A
o2) Maximum external leakage rate % N/A
p1) Internal mixing rate % N/A
p2) External mixing rate % N/A
q) Visual filter warning . N/A
r) Instructions to install regulated grilles check the instruction

booklet
s)| Internet address for pre/disassembly instructions| –| | www.aerauliqa.com|
t)| Airflow sensitivity to pressure variations| %| N/A
u)| Indoor/outdoor air tightness| m3/h| 52| 52| 132
v1)| AEC – Annual electricity consumption – warm climates| kWh| 0,4| 0,2| 0,3
v2)| AEC – Annual electricity consumption – average climates| kWh| 0,4| 0,2| 0,3
v3)| AEC – Annual electricity consumption – cold climates| kWh| 0,4| 0,2| 0,3
w1)| AHS – Annual heating saved – warm climates| kWh| 6,3| 11,9| 11,9
w2)| AHS – Annual heating saved – average climates| kWh| 14| 26,2| 26,2
w3)| AHS – Annual heating saved – cold climates| kWh| 27,3| 51,3| 51,3

NOTES

Warehouse-Offices: via Mario Calderara 39/41, 25018 Montichiari (Bs).
Bureau d’inscription: via Corsica 10, 25125 Brescia.
C.F. e P.IVA/VAT 03369930981 – REA BS-528635 – Tel: +39 030 674681 – Fax: +39 030 6872149 – www.aerauliqa.itinfo@aerauliqa.it
make improvements to products and/or this instruction manual at any time and without prior notice

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

aerauliqa User Manuals

Related Manuals