aerauliqa 003694 Quantum AX HT Silent Decentralised VMC Unit Installation Guide
- June 6, 2024
- aerauliqa
Table of Contents
Quantum AX
Read this manual carefully before using the product and keep it in a safe
place for reference.
This product was constructed up to standard and in compliance with regulations
relating to electrical equipment and must be installed by technically
qualified personnel.
The manufacturer assumes no responsibility for damage to persons or property
resulting from failure to observe the regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE, AND MAINTENANCE
-
The device should not be used for applications other than those specified in this manual.
-
After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small
children or people with disabilities. -
Do not touch the appliance with wet or damp hands/feet.
-
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Do not use the product in the presence of inflammable vapors, such as alcohol, insecticides, gasoline, etc.
-
If any abnormalities in operation are detected, disconnect the device from the main supply and contact a qualified technician immediately. Use original spare parts only for repairs.
-
The electrical system to which the device is connected must comply with regulations.
-
Before connecting the product to the power supply or the power outlet, ensure that:
– the data plate (voltage and frequency) correspond to those of the electrical mains
– the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician. -
The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from any type of combustion
unit. It must expel air outside via its own special duct. -
Operating temperature: 0°C up to +50°C.
-
The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
-
Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
-
Do not immerse the device or its parts in water or other liquids.
-
Turn off the main switch whenever a malfunction is detected or when cleaning.
-
For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
-
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
-
Do not obstruct the fan or exhaust grille to ensure optimum air passage.
-
Ensure adequate air return into the room in compliance with existing regulations in order to ensure proper device operation.
-
If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove, etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion, and proper equipment operation.
-
Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger (test probe “B” of the norm EN61032) in
compliance with the current safety regulations. -
Ceiling installation
In order to guarantee the IPX4 degree of protection against moisture in the case of ceiling installation, use the appropriate ceiling mount kit, which is not included. Use only the rear entry hole for supply cables. If there is a possibility of condensation along the air discharge duct, provide a drainage system to prevent condensation from discharging into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit. -
Window installation
In the case of window installation, it is necessary to use the appropriate window kit, which is not included.
Attention: do not mount the product on the window without this kit.
INTRODUCTION
Quantum AX is a decentralized mechanical ventilation unit designed to ensure
air extraction in small/medium-sized rooms.
Suitable for air discharge directly to the outside or in the presence of a
short ducted system. Wall, ceiling, or window installation (fig. 1).
TECHNICAL SPECIFICATIONS
- Material: High quality, impact, and UV-resistant ABS color RAL 9010.
- Design front covers removable for cleaning without the use of tools.
- Rear reinforcement ring to prevent spigot deformation during installation.
- High efficiency aerodynamic fan with “winglet” blades to optimize quietness and efficiency.
- Single-phase EC Brushless motor with integral thermal protection.
- Motor mounted on high-quality ball bearings.
- The fan is double insulated: no earth connection is required.
- Trickle speed selectable during installation.
- Option to boost from trickle (or from off) through LS connection.
- Installation type selection available (through wall or ducted).
- IPX4 degree of protection.
- Power supply 220-240V~ 50Hz.
VERSIONS
BASIC
The fan runs continuously at selected trickle speed (set by the jumper switch
combination fig. 15) and can be boosted with a dedicated ON/OFF switch (or PIR,
CO2…sensor) or with a light switch (fig. 13A). Trickle speed can be set to off
(fig. 15).
WITH HUMIDISTAT/TIMER
The fan is equipped with a humidity sensor, whose threshold is adjustable from
50% to 95% Relative Humidity via dedicated trimmer, and with a timer which is
adjustable from 0 to approx. 30 minutes via dedicated trimmer (fig. 14B).
The fan runs continuously at selected trickle speed (set by the jumper switch
combination fig. 15), increases its speed in case the percentage of Relative
Humidity exceeds the settable threshold, and can anyway be boosted with a
dedicated ON/OFF switch (or PIR, CO2…sensor) or with a light switch (fig. 13B).
Trickle speed can be set to off (fig. 15).
To deactivate the humidistat function, turn the trimmer HY completely
clockwise.
Automatic humidistat operation: when the percentage of Relative Humidity
exceeds the settable threshold, the fan speed automatically increases to
“comfort boost” speed, (intermediate between the selected trickle speed and
the boost speed). When the percentage of Relative Humidity goes below the
threshold, the fan continues to function at “comfort boost” speed for a
factory set period of time then returns to selected trickle speed.
Operation with external switch: (fig. 13B). When the external switch is turned
on, the fan is boosted. After the external switch is turned off, the fan
continues to run at boost speed for a settable period of time, then it returns
to selected trickle speed (or to “comfort boost” speed in case automatic
humidistat operation is on).
The front cover LED indicates when the external switch is on.
The over-run timer function is activated only if the external switch has been
on for at least 60 seconds.
INSTALLATION TYPESETTING
Installation type can be selected using JUMPER 1 between the following options: through a wall or ducted (fig. 15).
TRICKLE SPEED SETTING
Trickle speed can be selected using JUMPER (fig. 15).
DISPOSAL AND RECYCLING
Information on disposal of units at the end of life.
This product complies with EU Directive 2002/96/EC.
The symbol of the crossed-out dustbin indicates that this product must be
collected separately from other waste at the end of its life. The user must,
therefore, dispose of the product in question at suitable electronic and
electro-technical waste disposal collection centers, or else send the product
back to the retailer when purchasing a new, equivalent type device. Separate
collection of decommissioned equipment for recycling, treatment, and
environmentally compatible disposal helps to prevent negative effects on the
environment and on health and promotes the recycling of the materials that
make up the equipment. Improper disposal of the product by the user may result
in administrative sanctions as provided by law.
INSTALLATION
perimetrical exhausting | pannello | ceiling (accessory on demand) |
---|---|---|
window (kit on demand) | direct exhausting | short ducting |
MONTAGE AND WIRING DIAGRAM
Quantum AX 100
JUMPER| INSTALLAZIONE
INSTALLATION| PORTATA
AIRFLOW
1| 2| 3
| | | espulsione diretta / through wall| OFF
| | ✓| espulsione diretta I through wall| 21 m3Ih
| ✓| | espulsione diretta I through wall| 29m31h
| ✓| ✓| espulsione diretta I through wall| 47m31h
✓| | | canalization I in room| OFF
✓| | ✓| canalizzato / in room| 21m31h
✓| ✓| | canalizzato I in room| 29m31h
✓| ✓| ✓| canalizzato / in room| 47m31h (default)
Quantum AX 150
JUMPER
|
INSTALLAZIONE
INSTALLATION
|
PORTATA
AIRFLOW
1| 2| 3
| | | espulsione diretta / through wall| 22m31h
| | ✓| espulsione diretta / through wall| 29m31h
| ✓| | espulsione diretta / through wall| 47m31h
| ✓| ✓| espulsione diretta / through wall| 54m31h
✓| | | espulsione diretta / through wall| 61 m3/h
✓| | ✓| espulsione diretta / through wall| 76m3/h
✓| ✓| | espulsione diretta / through wall| 90m3/h
✓| ✓| ✓| espulsione diretta / through wall| 104m3/h (default)
PULIZIA – MAINTENANCE
ErP Directive – Regulations 1253/2014 – 1254/2014
a) | Mark | – | AERAULIQA |
---|---|---|---|
b) | Model | – | Quantum AX 100 |
c) | SEC class | – | E |
c1) | SEC warm climates | kWh/m2.a | -5,4 |
c2) | SEC average climates | kWh/m2.a | -13 |
c3) | SEC cold climates | kWhhT9.a | 4 |
Energy label | – | No | |
d) | Unit typology | Residential – unidirectional | |
e) | Type of drive | multi-speed drive | |
f) | Type of Heat Recovery System | – | absent |
g) | Thermal efficiency of heat recovery | % | N/A |
h) | Maximum flow rate | m3/h | 83 |
i) | Electric power input at a maximum flow rate | w | 2,6 |
j) | Sound power level (LWA) | dBA | 44 |
k) | Reference flow rate | m3/h | 61 |
l) | Reference pressure difference | Pa | 10 |
m) | Spedfic power input (SPI) | W/m3/h | 0,028 |
n1) | Control factors | – | 1 |
n2) | Control typology | – | Manual control |
--- | --- | --- | --- |
o1) | Maximum internal leakage rat | % | N/A |
o2) | Maximum external leakage rate | % | N/A |
p1) | Internal mixing rate | % | N/A |
p2) | External mixing rate | % | N/A |
q) | Visual filter warning | . | N/A |
r) | Instructions to install regulated grilles | – | check the instruction |
booklet
s)| Internet address for pre/disassembly instructions| –| |
www.aerauliqa.com|
t)| Airflow sensitivity to pressure variations| %| N/A
u)| Indoor/outdoor air tightness| m3/h| 52| 52| 132
v1)| AEC – Annual electricity consumption – warm climates| kWh| 0,4| 0,2| 0,3
v2)| AEC – Annual electricity consumption – average climates| kWh| 0,4| 0,2|
0,3
v3)| AEC – Annual electricity consumption – cold climates| kWh| 0,4| 0,2| 0,3
w1)| AHS – Annual heating saved – warm climates| kWh| 6,3| 11,9| 11,9
w2)| AHS – Annual heating saved – average climates| kWh| 14| 26,2| 26,2
w3)| AHS – Annual heating saved – cold climates| kWh| 27,3| 51,3| 51,3
NOTES
Warehouse-Offices: via Mario Calderara 39/41, 25018 Montichiari (Bs).
Bureau d’inscription: via Corsica 10, 25125 Brescia.
C.F. e P.IVA/VAT 03369930981 – REA BS-528635 – Tel: +39 030 674681 – Fax: +39
030 6872149 – www.aerauliqa.it –
info@aerauliqa.it
make improvements to products and/or this instruction manual at any time and
without prior notice
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>