aerauliqa QX Centrifugal Extract Fan Instruction Manual

October 30, 2023
aerauliqa

aerauliqa logo QX

aerauliqa QX Centrifugal Extract Fan

Installation Manual

Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this booklet.

Precautions For Installation, use and maintenance

  • The device should not be used for applications other than those specified in this manual.
  • After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small children or people with disabilities.
  • Do not touch the appliance with wet or damp hands/feet.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and undersiand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Do not use the product in the presence of flammable vapours, such as alcohol, insecticides, gasoline, etc.
  • If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use original spare parts only for repairs.
  • The electrical system to which the device is connected must comply with regulations.
  • Before connecting the product to the power supply or the power outlet, ensure that: – the data plate (voltage and frequency) correspond to those of the electrical mains – the electncal power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
  • The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from any type of combustion unit. It must expel air outside via its own special duct.
  • Operating temperature: 0°C up to +50°C.
  • The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
  • Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
  • Do not immerse the device or its parts in water or other liquids.
  • Turn off the main switch whenever a malfunction is detected or when cleaning.
  • For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifiedpersons in order to avoid a hazard.
  • Do not obstruct the fan or exhaust grille to ensure optimum air passage.
  • Ensure adequate air retum into the room in compliance with existing regulations in order to ensure proper device operation.
  • If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.
  • Install the product so that the impeller is not accessible from the air outlet side as verifiedby contact with the Test Finger (test probe “B” of the norm EN61032) in compliance with the current safety regulations.
  • Ceiling installation In order to guarantee the IPX4 degree of protection against moisture in case of ceiling installation, use the appropriate ceiling mount kit, which is not included. Use only the rear entry hole for supply cables. If there is a possibility of condensation along the air discharge duct, provide a drainage system to prevent condensation from discharging into the environment through the fan. Attention: do not mount the product on the ceiling without this kit.
  • Recessed installation In case of recessed installation in plasterboard walls, the specific fixing kit must be used (accessory on request).

INTRODUCTION

QX is a centrifgual fan designed to ensure air extraction in small/medium- sized rooms such as bathrooms, toilets and kitchens. Suitable for air discharge through long length ducting. Wall or ceiling installation, surface or recessed in plasterboard walls (fig. 1).

TECHNICAL SPECIFICATIONS

  • Material: High quality, impact and UV-resistant ABS colour RAL 9010.
  • Design front cover removable for cleaning without the use of tools
  • Removable filter in PP to protect the impeller and the motor from dust.
  • Highly quality forward-curved impeller for high performance and top silence.
  • Single phase 2-speed motor with integral thermal protection.
  • Motor mounted on ball bearings that guarantee a longer product life cycle (30,000h) and suitable for cold climates.
  • The fan is double insulated: no earth connection is required.
  • Suitable for continuous or intermittent operation.
  • IPX4 degree of protection.
  • Power supply 220V to 240V- 50160Hz.

VERSIONS
STANDARD
The fan is operated using a separate ON/OFF switch or via a light switch (fig. 48A).
WITH TIMER (over-run)
The fan is provided with a timer circuit which is adjustable from aprox. 1 minute to 25 minutes via trimmer (fig. 49A). Operation: connected according to the diagram in fig. 48B, after the light is switched on, the fan activates with a delay of max 1.5 seconds. After the light is switched off, the fan continues to function for a pre-set period of time.
STANDARD
The fan is operated using a separate ON/OFF switch or via a light switch (fig. 48A). WITH TIMER (over-run) The fan is provided with a timer circuit which is adjustable from aprox. 1 minute to 25 minutes via trimmer (fig. 49A). Operation: connected according to the diagram in fig. 48B, after the light is switched on, the fan activates with a delay of max 1.5 seconds. After the light is switched off, the fan continues to function for a pre-set period of time.
WITH HUMIDISTAT & TIMER
The fan is equipped with a humidity detector, whose threshold is adjustable from 50% to 95% Relative Humidity, and with a timer which is adjustable from aprox. 1 minute to 25 minutes via corresponding trimmer (fig. 49B). Turn the trimmer HY completely clockwise and the humidistat function is deactivated. Automatic humidistat operation: connected according to the diagram in fig. 48B, when the percentage of Relative Humidity exceeds the pre-set intervention threshold, the fan starts up automatically. When the percentage of Relative Humidity goes below the threshold, the fan continues to function for a pre-set period of time. Operation with switch connection: connected according to the diagram in fig. 48B, after the light is switched on, the fan activates with a delay of aprox. 1.5 seconds. After it is switched off, the fan continues to function
for a pre-set period of time.
Attention: when the relative humidity level is higher than the pre-set threshold, automatic operation with humidistat has priority over manual operation, or rather the fan cannot be stopped via switch.

Installation

perimetrical exhausting

|
---|---
wall – surface| wall – recessed (accessory on demand)
|
ceiling – surface (accessory on demand)| ceiling – recessed (accessory on demand)

MOUNTING

aerauliqa QX Centrifugal Extract Fan - MOUNTING 1aerauliqa QX Centrifugal Extract Fan -
Fig2aerauliqa QX Centrifugal Extract Fan - Fig
3aerauliqa QX Centrifugal Extract Fan - Fig
4aerauliqa QX Centrifugal Extract Fan - Fig
5aerauliqa QX Centrifugal Extract Fan - Fig
6

PLASTERBOARD FIXING KIT (ACCESSORY ON REQUEST) – KIT DE FIXATION PLAQUE DE PLATRE (ACCESSOIRE SUR

aerauliqa QX Centrifugal Extract Fan - Fig 7aerauliqa QX Centrifugal Extract Fan - Fig 8aerauliqa QX Centrifugal Extract Fan - Fig 9

ELECTRICL WARNING

aerauliqa QX Centrifugal Extract Fan - Fig 10

MAINTENANCE/CLEANING

aerauliqa QX Centrifugal Extract Fan - Fig 11

DISPOSAL AND RECYCLING

Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device. Separate collection of decommissioned equipment for recycling, treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment. Improper disposal of the product by the user may result in administrative sanctions as provided by law.

Directive – Regulations 1253/2014 – 1254/2014 —

a) Mark
**** b) Model
c) SEC class
c1) SEC warm climates kWh/m2.a кВт/м2.a
c2) SEC average climates e kWh/m2.a кВт/м2.a
c3) SEC cold climates kWh/m2.a кВт/м2.a
  Energy label
d) Unit typology
e) Type of drive
f) Type of Heat Recovery System
g) Thermal efficiency of heat recovery %
h) Maximum flow rate m3/h м3/час
i) Electric power input at maximum flow rate – W Вт
j) Sound power level (LWA) dBA Дб
k) Reference flow rate m3/h м3/час
l) Reference pressure difference Pa Па
m)  Specific power input (SPI) W/m3/h Вт/м3/час
n1) Control factor
n2) Control typology
o1) Maximum internal leakage rate %

Dirctive

AERAULIQA

QX80, QX80T QX100, QX100T| QX80HT QX100HT
F| C
0,8| -7,7
-8,6| -23,2
-25| -50,2
Нет
Residential
single speed drive
*** absent
N/A; –
104| 104
28| 28
59| 59
104| 104
10| 10
0,274| 0,274
1| 0,65
 Manual control| Manual control (no DCV)
N/A; –
o2)| Maximum external leakage rate| %
---|---|---
p1)| Internal mixing rate| %
p2)| External mixing rate| %
q)| Visual filter warning| –
r)| Instructions to install regulated grilles| –
s)| Internet address for pre/disassembly instructions| –
t)| Airflow sensitivity to pressure variations| %
u)| Indoor/outdoor air tightness| m3/h m3/час
v1)| AEC – Annual electricity consumption| kWh кВт
ч
v2)| AEC – Annual electricity consumption| kWh кВтч
v3)| AEC – Annual electricity consumption| kWh кВт
ч
w1)| Annual heating saved – warm climates| kWh кВт*ч

AERAULIQA


QX80, QX80T QX100, QX100T|

QX80HT QX100HT

F| C
0,8| -7,7
-8,6| -23,2
-25| -50,2
Нет
Residential –
single speed drive
absent
N/A; –
104| 104
28| 28
59| 59
104| 104
10| 10
0,274| 0,274
1| 0,65
Manual control (no DCV)| Manual control (no DCV)
N/A; –

aerauliqa logoRegistered office
C.F. e P.IVANAT 03369930981 – REA BS-528635
Tel: +39 030 674681 –
Fax: +39 030 6872149 – www.aerauliqa.cominfo@aerauliqa.it
Aerauliqa sri reserves the right to modify/make improvements to products and/or this instruction manual at any time and without prior notice.
CFI0002Q – 12 – 0323

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

aerauliqa User Manuals

Related Manuals