TRAXON ProPoint Kontour Highlighting Luminaire Installation Guide
- July 15, 2024
- traxon
Table of Contents
ProPoint Kontour Highlighting Luminaire
Specifications
- Kontour Narrow Bracket Dimension: 46.5mm / 1.8
- Kontour Wide Bracket Dimension: 75mm / 3
- Mounting Bracket Size: 84mm / 3.3 (With Mounting Bracket) / 70mm / 2.8 (Without Mounting Bracket)
Product Usage Instructions
Mounting the Bracket
- Attach the mounting bracket to the surface using appropriate hardware (not included).
- Use a screwdriver type M3 hex driver and M3 screw (included) to secure the bracket in place.
- If using the safety cable (optional accessory), attach it to the fixture for added security.
Minimum Bending Radius and Non-Bendable Length
- Minimum Bending Radius: 50.4mm / 1.98
- Non-Bendable Length: Ensure the minimum spacing for thermal expansion is at least 4mm/0.16.
Power/Data Input and Output
- Power/Data input side should be connected as per the specified dimensions.
- Power/Data output side should also be connected accordingly.
Referencing Installation Guide:
If further details are required, please refer to section 2.3.1 from the
ProPoint Kontour Installation Guide.
FAQ
-
What should I do if I don’t have the necessary hardware to mount the bracket?
- If you do not have the required hardware, please purchase suitable screws and anchors from a hardware store to securely mount the bracket to the surface.
-
Is the safety cable necessary for installation?
- The safety cable is an optional accessory for added security. While it is not mandatory, it is recommended for additional safety measures.
ProPoint Kontour Mounting Guide
| 300mm / 12”| 600mm / 24”| 1200mm / 48”| 2400mm / 96”
---|---|---|---|---
A| 75mm / 3”| N / A| N / A| N / A
B| 300mm / 11.8”| 600mm / 23.6”| 1200mm / 47.2”| 2400mm / 94.5”
C| 100mm / 3.9”| 15mm / 0.6”| 15mm / 0.6”| 15mm / 0.6”
D| 130mm / 5.1”| 250mm / 9.8”| 540mm / 21.3”| 1500mm / 59”
Assembly Instruction
-
CONNECT TO THE POWER SUPPLY IN ACCORDANCE WITH NATIONAL REGULATIONS.
-
IF THE EXTERNAL FLEXIBLE CABLE OF THIS LUMINAIRE IS DAMAGED,
IT SHALL BE EXCLUSIVELY REPLACED BY THE MANUFACTURER OR A SIMILAR QUALIFIED PERSON IN ORDER TO AVOID ANY HAZARD. -
INSTALLATION/MAINTENANCE ONLY BY SKILLED PERSONNEL.
-
DURING OVERHAUL/MAINTENANCE ONLY USE ORIGINAL PARTS.
-
IF ANY LUMINAIRE IS SUBSEQUENTLY MODIFIED, THE PERSON RESPONSIBLE FOR THE MODIFICATION SHALL BE CONSIDERED THE MANUFACTURER.
-
THE MANUFACTURER BEARS NO LIABILITY FOR DAMAGE CAUSED BY INAPPROPRIATE USE OR APPLICATION.
-
THE LIGHT SOURCE OF THIS LUMINAIRE IS NOT REPLACEABLE; WHEN THE LIGHT SOURCE REACHES ITS END OF LIFE THE WHOLE LUMINAIRE SHALL BE REPLACED.
-
THE LUMINAIRE SHOULD BE POSITIONED SO THAT PROLONGED STARING INTO THE LUMINAIRE AT A DISTANCE CLOSER THAN 4M IS NOT EXPECTED.
OTHER PATENTS PENNON, SPECIATIONS ARE SUBJECT TO CHANGE WITHOUT NO AGE TRADEMARKS OF TRAXON TECHNOLOGIES, U.S, PATENTS, E.U. PATENTS, JAPAN PATENTS, Mounting Guida 12/20 VI.O