Posey 1135 Self Releasing Roll Belt Instructions

July 13, 2024
Posey

Posey 1135 Self Releasing Roll Belt

Specifications

  • Product Name: Self-Releasing Roll Belt
  • Applicable Products: REF 1135, 1135QR, 1135QXL
  • Material: Cotton
  • Intended Use : Hospital bed use only

Product Usage Instructions

  • Before use, check the device for damage and ensure that the hook and loop adhere securely. Discard if unsure about patient safety.
  • Open the belt and center it across the mattress.

For added safety, consider using a restraint with a pelvic piece to reduce the risk of sliding. Refer to the Posey Catalog for more information.

  • Wrap the strap around the frame that moves with the patient, leaving an 8-inch tail.
  • Fold the loose end in half to create a loop and cross it over the other end.
  • Insert the folded strap where the straps cross over each other, similar to tying a shoelace.
  • Create a second loop with the loose end and insert it into the first loop.
  • Test to ensure the strap is secure and will not slide.
  • Repeat on the other side and practice quick-release ties for easy release.

FAQ

  • Q: What should I do if the product is uncomfortable or limits movement?
  • A: If the product causes discomfort or severely limits movement, seek help from a qualified medical authority to find a less restrictive alternative.
  • Q: What should I do if the belt does not fasten securely?
  • A: Ensure proper application and consider environmental factors such as humidity levels. Avoid excess moisture or high humidity that may affect product materials.

DESCRIPTION OF PRODUCT

  • Self-Releasing Cotton Belt with quick-release buckle.
  • For hospital bed use only.

INDICATIONS FOR USE

  • Patients needing a reminder to call for assistance before exiting a bed, and are able to follow instructions.
  • Patients needing a positioning device for added safety while in a bed.

CAUTION: This product is designed for self-release. If the patient is not able to easily self-release, it is considered a restraint and must be prescribed by a physician.

CONTRAINDICATIONS

  • DO NOT use on a patient who is or becomes highly aggressive, combative, agitated, or suicidal.
  • DO NOT use on patients with: ostomy, colostomy, or G-tubes; hernias, severe Cardio Obstructive Pulmonary Disease (COPD); or with post-surgery tubes, incisions or monitoring lines. These could be disrupted by a restraint.
  • DO NOT use on a patient who is unwilling or unable to follow instructions, and is at risk of a fall or re-injury from self-release.

POSEY SELF-RELEASING ROLL BELT

  • REF 1135 Self-Releasing Roll Belt
  • REF 1135QR Self-Releasing Roll Belt with Quick- Release Buckles
  • REF 1135QXL Self Releasing Roll Belt (XL) with Quick-Release Buckles

ADVERSE REACTIONS
Severe emotional, psychological, or physical problems may occur: if the applied device is uncomfortable; or if it severely limits movement. If symptoms of these problems ever appear for any reason, get help from a qualified medical authority and find a less restrictive, product or intervention.

APPLICATION INSTRUCTIONS

CAUTION: Before use, check device for damage and that hook and loop adheres securely. Discard if you have any questions about patient safety.

  1. Open the belt and center it across the mattress with the waistband facing up. The hook fastening section will be located on the right side, and the long straps will hang off both sides of the bed.
  2. Position the patient in bed with the belt at waist level.
  3. Bring the belt around the patient’s waist and secure with the hook and loop fastener. Connect the quick-release buckle. The belt must be snug, but not interfere with breathing. To check for proper fit, slide an open hand (flat) between the belt and the patient.
  4. Attach the two long straps on each side to a movable part of the bed frame, at waist level, using quick-release ties or buckles.
  5. Check that the straps are secure and will not change position, loosen, or tighten if the patient pulls on them, or if the bed is adjusted.

WARNING: Heed these warnings to reduce the risk of serious injury or death:

BED SAFETY

  • ALWAYS use Hospital Bed Safety Workgroup (HBSW) (http://www.fda.gov/cdrh/beds/modguide.html) compliant side rails in the UP position and fill ALL gaps to reduce the risk of entrapment.
  • Use side rail covers and gap protectors to help prevent the patient’s body from going under, around, through or between the side rails. A failure to do so may result in serious injury or death if a patient becomes suspended or entrapped. Posey offers a full range of side rail pads and/ or gap protectors to cover gaps.

WARNING

  • There is a risk of chest compression or suffocation, if the patient’s body weight is suspended off the mattress (figs. 1 and 2).
  • Monitor per facility policy to ensure that the patient cannot slide down, or fall off the mattress and become suspended or entrapped (figs. 1 and 2).
  • STOP USE AT ONCE: if the patient is at risk to slide forward or down in the device.
  • NOTE: A restraint with a pelvic piece will help to reduce the risk of sliding. See Posey Catalog.
  • Before leaving the patient unattended, explain the purpose for the belt. Make sure the patient understands:
  • the need to call for assistance before exiting the bed; and
  • how to self-release in an emergency.

For RX PRODUCTS ONLY. Federal law (USA) restricts RX devices to sale by or on order of a physician. For use in a licensed healthcare facility only.
STAFF TRAINING : TIDI offers in-service training aids at no charge. Contact TIDI online at www.tidiproducts.com or call toll-free at 1.800.521.1314.
BEFORE APPLYING ANY RESTRAINT : Follow your hospital’s restraint policies and procedures that are compliant with USA CMS guidelines and state laws or other governing agencies outside the USA.

ADDITIONAL WARNINGS

  1. ALWAYS monitor patient per facility policy. Improper application or use of any restraint may result in serious injury or death. Be aware that constant monitoring may be required for:

    • Aggressive or agitated patients; and
    • Patients in a supine position; ensure that being in this position would not cause any complications for those who are at risk of vomiting while being restrained.
  2. NEVER alter or repair this product. ALWAYS Inspect before each use: Check for broken stitches or parts; torn, cut or frayed material; or locks, buckles, or hook-and-loop fasteners that do not hold securely. DO NOT use soiled or damaged products. Doing so may result in serious injury or death. Dispose of damaged products per facility policy for BIOHAZARDOUS material.

  3. ALWAYS secure straps to a part of the frame that moves with the patient (not foot/head board or siderails), out of the patients reach, using quickrelease ties (see drawing below) or buckles. These allow easy release in the event of an accident or fire.
    Test to make sure straps cannot tighten, loosen, or slip and create excess slack. If this occurs, the patient may slide off the chair or bed, increasing the risk of serious injury or suffocation. Restraint release is an important part of facility fire and disaster drills. Straps can be cut with scissors in an emergency.

  4. NEVER secure restraint strap to side rail or head/foot board.

  5. NEVER use Posey products on toilets, or on any chair or furniture that does not allow proper application as directed in the Application Instructions. DO NOT use at home.

  6. NEVER expose this product to open flame, fire, smoking materials, or high heat sources. Some products may melt or ignite and burn. The facility smoking/no smoking policy should be strictly enforced.

  7. NEVER use a Posey product as a seat belt in a moving vehicle. Posey products are not designed to withstand the force of a crash or sudden stop.

  8. Test Zippers or hook-and-loop fasteners before each use. DISCARD device if it does not fasten securely.

LAUNDERING INSTRUCTIONS (if applicable)

  • Fasten all buckles and locks to reduce risk of damage during wash and dry cycles. DO NOT put buckles or locks through extractors. For maximum life, launder in a laundry bag.
  • Stainless Steel Locks: Posey recommends that locks be treated with a dryfilm lubricant (silicone) after each cleaning. For best results, spray a small amount into the lock. Work the action of the lock with a key several times to ensure that all the surfaces are well lubricated.
  • Before laundering, zip up and turn the product inside out to protect the zipper.
  • Hook-and-loop fasteners may collect lint after repeated use or laundering, reducing grip strength. Fasten the “hook” to the “loop” before laundering to help prevent lint buildup. As needed, use a stiff-bristle brush to remove lint from the “hook” side.
  • These products, other than foam products, can be machine washed under CDC guidelines for material soiled with blood or bodily fluid.
  • For non-contaminated material, use lower temperature wash and dry cycles to extend product life.
  • For foam products:
  • Make sure products are completely dry before use.

STORAGE AND HANDLING

  • This device is designed for use in normal indoor environments.
  • This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.

HOW TO TIE THE POSEY QUICK-RELEASE TIE

  1. Wrap strap once around the frame that moves with the patient (do not attach to side rail or head/footboard), leaving at least an 8” (20 cm) tail.
    Fold the loose end in half to create a loop and cross it over the other end.

  2. Insert the folded strap where the straps cross over each other, as if tying a shoelace. Pull on the loop to tighten.

  3. Fold the loose end in half to create a second loop.

  4. Insert the second loop into the first loop.

  5. Pull on the loop to tighten. Test to make sure strap is secure and will not slide in any direction.

  6. Repeat on other side. Practice quick-release ties to ensure the knot releases with one pull on the loose end of the strap.

Report any serious incident related to device use to TIDI Products and the Member State Competent Authority. | Translations of this document in French, Spanish, Dutch, German, Italian, and Portuguese are located at www.tidiproducts.com/IFU.

DISPOSAL: Dispose of product according to local or facility guidelines if product is worn or damaged.

CONTACT

  • TIDI Products, LLC
  • 570 Enterprise Drive, Neenah, WI 54956 USA
  • Phone: 1.800.521.1314
  • International: +1.920.751.4036
  • www.tidiproducts.com

MDSS GmbH

  • Schiffgraben 41
  • 30175 Hannover, Germany

UK Responsible Person

  • Emergo Consulting (UK) Limited
  • c/o Cr360 – UL International
  • Compass House, Vision Park Histon
  • Cambridge CB249BZ
  • United Kingdom

© 2023 TIDI Products, LLC. All rights reserved. Posey is a registered trademark of TIDI Products, LLC.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals