DESCRIPTION OF PRODUCT:
The Roll Belt is designed to allow the patient freedom to roll from side to side or sit up in bed. Bed application only. Rx ONLY
POSEY ROLL BELTS
REF 1201 Flame Retardant
REF 1231 Cotton, connecting straps for quick-release ties
REF 1231Q Cotton, connecting straps w/quick-release buckles
REF 1231QXL Cotton, connecting straps w/quick-release buckles
INDICATIONS FOR USE:
- Patients assessed to be at risk of injury from a fall.
- Patients needing freedom to roll from side to side or sit up in bed
CONTRAINDICATIONS:
- DO NOT use on a patient who is or becomes highly aggressive, combative, agitated, or suicidal.
- DO NOT use on patients with: Tommy, colostomy, or G-tubes; hernias, severe Cardio Obstructive Pulmonary Disease ( COPD ); or with post-surgery tubes, incisions or monitoring lines. These could be disrupted by a restraint.
ADVERSE REACTIONS
- Severe emotional, psychological, or physical problems may occur: if the applied device is uncomfortable; or if it severely limits movement. If symptoms of these problems ever appear for any reason, get help from a qualified medical authority and find a less restrictive, product or intervention.
APPLICATION INSTRUCTIONS: (Increased Movement)
Caution
Before use, check device for damage. Discard if you have any questions about
patient safety.
- Open the belt and center it across the mattress with the flannel side toward the small of the patient’s back.
- Position the patient in bed with the belt at waist level.
- Secure the short strap to a movable part of the bed frame, with a quick-release tie or buckle, out of the patient’s reach.
- Bring the long strap over, around the patient’s waist and back behind the patient through the slot in the back pad.
- Secure the long strap to a movable part of the bed frame, with a quick-release tie or buckle, out of the patient’s reach. The belt must be snug, but not interfere with breathing. To check for proper fit, slide an open hand (flat) between the belt and the patient.
- Check that the straps are secure and will not change position, loosen, or tighten if the patient pulls on them, or if the bed is adjusted.
APPLICATION INSTRUCTIONS (Decreased Movement):
-
Open the belt and center it across the mattress with the flannel side toward the small of the patient’s back.
-
Position the patient in bed with the belt at waist level.
-
Secure the short strap to a movable part of the bed frame, with a quick-release tie or buckle, out of the patient’s reach.
-
Bring the long strap over, around the patient’s waist and in front of the patient through the slot in the front (fig. 1).
-
Secure the long strap to movable part of the bed frame, with a quick-release tie or buckle, out of the patient’s reach. The belt must be snug, but not interfere with breathing. To check for proper fit, slide an open hand (flat) between the belt and the patient.
-
Check that the straps are secure and will not change position, loosen, or tighten if the patient pulls on them, or if the bed is adjusted.
Warning
Heed these warnings to reduce the risk of serious injury or death:
BED SAFETY
-
ALWAYS use Hospital Bed Safety Work group (HOBBS) (http://www.fda.gov/cdrh/beds/modguide.html) compliant side rails in the UP position and fill ALL gaps to reduce the risk of entrapment.
-
Use side rail covers and gap protectors to help prevent the patient’s body from going under, around, through or between the side rails. A failure to do so may result in serious injury or death if a patient becomes suspended or entrapped. Posey offers a full range of side rail pads and/or gap protectors to cover gaps.
-
There is a risk of chest compression or suffocation, if the patient’s body weight is suspended off the mattress (figs. 2 and 3).
-
Monitor per facility policy to ensure that the patient cannot slide down, or fall off the mattress and become suspended or entrapped **(figs. 2 and 3).
**
- STOP USE AT ONCE: if the patient has a tendency to slide forward or down in the device; or is able to self-release.
NOTE: A restraint with a pelvic piece will reduce the risk of sliding, or of the patient pulling the device over his or her head. See Posey Catalogue.
ADDITIONAL SAFETY AND LAUNDERING INSTRUCTIONS ON OTHER SIDE
Safety Information for the use of Posey ® Restraining Products
For RX PRODUCTS ONLY. Federal law (USA) restricts RX devices to sale by or on order of a physician. For use in a licensed healthcare facility only.
STAFF TRAINING: TIDI offers in-service training aids at no charge. Contact TIDI online at www.tidiproducts.com or call toll-free at 1.800.521.1314.
BEFORE APPLYING ANY RESTRAINT : Follow your hospital’s restraint policies and procedures that are compliant with USA CMS guidelines and state laws or other governing agencies outside the USA.
ADDITIONAL WARNINGS:
-
ALWAYS monitor patient per facility policy. Improper application or use of any restraint may result in serious injury or death. Be aware that constant monitoring may be required for:
-
Aggressive or agitated patients; and
-
Patients in a supine position; ensure that being in this position would not cause any complications for those who are at risk of vomiting while being restrained.
-
NEVER alter or repair this product. ALWAYS Inspect before each use: Check for broken stitches or parts; torn, cut or frayed material; or locks, buckles, or hook-and-loop fasteners that do not hold securely. DO NOT use soiled or damaged products. Doing so may result in serious injury or death. Dispose of damaged products per facility policy for BIO HAZARDOUS material.
-
ALWAYS secure straps to a part of the frame that moves with the patient (not foot/head board or side rails), out of the patients reach, using quick release ties (see drawing below) or buckles. These allow easy release in the event of an accident or fire.
Test to make sure straps cannot tighten, loosen, or slip and create excess slack. If this occurs, the patient may slide off the chair or bed, increasing the risk of serious injury or suffocation. Restraint release is an important part of facility fire and disaster drills. Straps can be cut with scissors in an emergency. -
NEVER secure restraint strap to side rail or head/foot board.
-
NEVER use Posey products on toilets, or on any chair or furniture that does not allow proper application as directed in the Application Instructions. DO NOT use at home.
-
NEVER expose this product to open flame, fire, smoking materials, or high heat sources. Some products may melt or ignite and burn. The facility smoking/no smoking policy should be strictly enforced.
-
NEVER use a Posey product as a seat belt in a moving vehicle. Posey products are not designed to withstand the force of a crash or sudden stop.
-
Test Zippers or hook-and-loop fasteners before each use. DISCARD device if it does not fasten securely.
LAUNDERING INSTRUCTIONS (if applicable):
-
Fasten all buckles and locks to reduce risk of damage during wash and dry cycles. DO NOT put buckles or locks through extractors. For maximum life, launder in a laundry bag.
-
Stainless Steel Locks: Posey recommends that locks be treated with a dry film lubricant (silicone) after each cleaning. For best results, spray a small amount into the lock. Work the action of the lock with a key several times to ensure that all the surfaces are well lubricated.
-
Before laundering, zip up and turn the product inside out to protect zipper.
-
Hook-and-loop fasteners may collect lint after repeated use or laundering, reducing grip strength. Fasten the “hook” to the “loop” before laundering to help prevent lint buildup. As needed, use a stiff-bristle brush to remove lint from the “hook” side.
-
These products, other than foam products, can be machine washed under CDC guidelines for material soiled with blood or bodily fluid.
WASH HOT 25 ΜΙΝ.
BLEACH AS DIRECTED ON CONTAINER
DRY ON LOW -
For non-contaminated material, use lower temperature wash and dry cycles to extend product life.
-
For foam products:
WASH LUKEWARM
BLEACH AS DIRECTED ON CONTAINER
DRY ON LOW -
Make sure products are completely dry before use.
STORAGE AND HANDLING:
- This device is designed for use in normal indoor environments.
- This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.
HOW TO TIE THE POSEY QUICK-RELEASE TIE
-
Wrap strap once around the frame that moves with the patient (do not attach to side rail or head/foot board), leaving at least an 8” (20 cm) tail.
Fold the loose end in half to create a loop and cross it over the other end. -
Insert the folded strap where the straps cross over each other, as if tying a shoelace. Pull on the loop to tighten.
-
Fold the loose end in half to create a second loop.
-
Insert the second loop into the first loop.
-
Pull on the loop to tighten. Test to make sure strap is secure and will not slide in any direction.
-
Repeat on other side. Practice quick-release ties to ensure the knot releases with one pull on the loose end of the strap.
Report any serious incident related to device use to TIDI Products and the Member State Competent Authority. | Translations of this document in French, Spanish, Dutch, German, Italian, and Portuguese are located at www.tidiproducts.com/IFU
DISPOSAL : Dispose of product according to local or facility guidelines if product is worn or damaged.
TIDI Products, LLC
570 Enterprise Drive, Nee nah, WI 54956 USA
Phone : 1.800.521.1314
International: +1.920.751.4036
www.tidiproducts.com
MDSS GmbH
Schizophrenia 41
30175 Hanover, Germany
UK Responsible Person
Emergo Consulting (UK) Limited
c/o Cr360 – UL International
Compass House, Vision Park Huston
Cambridge CB249BZ
United Kingdom
© 2023 TIDI Products, LLC. All rights reserved. Posey is a registered trademark of TIDI Products, LLC.
References
- U.S. Food and Drug Administration
- Posey | First in Patient Safety
- Medical Products for Staff & Patient Safety | TIDI Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>