Posey 2796, 2797 Connected Twice as Tough Cuffs for Stretcher Instructions

July 13, 2024
Posey

Posey 2796, 2797 Connected Twice as Tough Cuffs for Stretcher

Posey-2796-2797-Connected-Twice-as-Tough-Cuffs-for-Stretcher-product-
image

Specifications:

  • Product Name: Posey Stretcher Connected Twice-As-Tough Limb Holder
  • Models Available: 2796 (Regular Wrist/Blue), 2797 (Large Ankle/Red)
  • Features: Padded limb restraints with double-security closure
  • Intended Use: For stretcher use only
  • Manufacturer: TIDI Products

Product Usage Instructions

Application Instructions:

  1. Place the cuffs at the wrist or ankle position.
  2. Thread the strap through the D-rings as shown in Fig. 1 and Fig. 2, ensuring it is attached to the frame that moves with the patient.
  3. Position the patient on the bed ensuring the cuffs are out of reach.

Applying the Cuffs :

  1. Wrap the neoprene piece around the wrist/ankle and secure the hook-and-loop closure as described in Fig. 3.
  2. Pass the end of the limb strap through the D-rings on the cuff and ensure a proper fit.

Adjusting Strap Length :
Adjust the connecting strap(s) length to allow desired freedom of movement while ensuring patient and caregiver safety. Secure any remaining strap end(s) out of reach of the patient.

To Remove :
Release the cuff from the patient and then release the anchor strap from the bed frame.

FAQ :

  • Q: Can these limb restraints restrict circulation?
    A: Yes, it is important to ensure that the cuffs do not restrict circulation when applied. If there are signs of restricted circulation, remove the limb holder immediately.

Posey® Connected Twice-As-Tough® Cuffs for Stretcher 2796, 2797 Application Instructions for Wrist and Ankle
DESCRIPTION OF PRODUCT: Padded limb restraints with double-security closure. For stretcher use only.

INTENDED USE

  • To protect patients assessed to be at risk of disrupting life-saving treatments (e.g., chronic tube pulling) or in danger of injury to themselves or to others by limiting limb movement in a bed or stretcher.
  • Follow your hospital’s restraint policies and procedures that are compliant with USA
  • CMS guidelines and state laws, or other governing agencies outside the USA.
  • CONTRAINDICATIONS : None.

APPLICATION INSTRUCTIONS : Follow these steps to apply device (repeat steps 1-3 on each side):

  1. Place the cuffs at wrist or ankle position.
  2. Bring the ends of the strap down through the inside of the side rails so they do not interfere when the side rails are raised. Thread the end of the strap over the top, around the frame at least once, and through the two D-rings. Bring the strap back over the first ring and through the second D-ring (Fig. 1). Make sure that the straps are attached to the frame that moves with the patient (Fig. 2) (do not attach to side rail or head/footboard), out of the patient’s reach. Position the patient on the bed.

APPLYING THE CUFFS : (Repeat steps 1-2 for each side):

  1. Wrap the neoprene piece around wrist/ankle. Attach the black hook-and-loop pieces together and pull back the black pull tab on the blue or red fuzzy piece, followed by the blue or red hook-and-loop pieces. The fuzzy piece should be sandwiched between the two pieces of hook (Fig. 3). Be sure to overlap at least one inch (3 cm).
  2. 2. Press the hook-and-loop closure together firmly and make
    sure it adheres securely. Slide ONE finger (flat) between the cuff and the inside of the patient’s wrist/ankle to ensure proper fit.
    2796: Pass the end of the limb strap over the top of the cuff and through the two D- rings on the cuff. Bring the strap back over the first ring and through the second D-ring on the cuff (Fig. 1). Slide one finger (flat) between the cuff and limb strap.
    ADJUSTING STRAP LENGTH : Adjust the connecting strap(s) length from the frame to allow desired freedom of movement without compromising patient or caregiver safety. Ensure the remaining strap end(s) are secured and out of the reach of the patient.
    TO REMOVE : Release the cuff from the patient. Release the anchor strap from the bed frame.

PRECAUTIONS :

  • A clinical assessment and decision are required when used with monitoring lines or if patient has a wound or dislocated/fractured limb.
  • Check the patient regularly to ensure that circulation is not impaired. Serious injury may occur if the cuffs restricts circulation when the limb holder is applied.

Posey-2796-2797-Connected-Twice-as-Tough-Cuffs-for-Stretcher-
\(3\)

POSEY STRETCHER CONNECTED TWICE-AS-TOUGH LIMB HOLDER:

  •  2796
    D-Ring Connected Cuff (single strap with D-Rings), Regular Wrist/Blue

  • 2797
    Hook & Loop Connected Cuff (single strap with D-Rings), Large Ankle/Red

WARNING : Additional or different body or limb restraints may be needed (visit tidiproducts.com):

  • Some patients may require additional interventions in conjunction with a restraint in order to prevent injury to self or others.
    • If the patient pulls violently against the bed straps.
    • To reduce the risk of the patient getting access to the line/wound/tube site.
    • To prevent the patient from flailing or bucking up and down and causing self-injury.
  • It is a clinical decision to decide when a restraint is no longer deemed safe.

BED SAFETY : Refer to the Food and Drug Administration (FDA), or other governing agencies outside the USA, for the most recent Hospital Bed Safety Guidelines and the bed manufacturer’s instructions for use.

ADDITIONAL SAFETY AND LAUNDERING INSTRUCTIONS ON OTHER SIDE.

  • For RX PRODUCTS ONLY. Federal law (USA) restricts RX devices to sale by  or on order of a physician. For use in a licensed healthcare facility only.
  • STAFF TRAINING: TIDI offers in-service training aids at no charge. Contact TIDI online at www.tidiproducts.com or call toll-free at 1.800.521.1314.
  • BEFORE APPLYING ANY RESTRAINT: Follow your hospital’s restraint policies and procedures that are compliant with USA CMS guidelines and state laws or other governing agencies outside the USA.

ADDITIONAL WARNINGS:

  1. ALWAYS monitor patient per facility policy. Improper application or use of any restraint may result in serious injury or death. Be aware that constant monitoring may be required for:

    • Aggressive or agitated patients; and
    • Patients in a supine positon; ensure that being in this position would not cause any complications for those who are at risk of vomiting while being restrained.
  2. NEVER alter or repair this product. ALWAYS Inspect before each use: Check for broken stitches or parts; torn, cut or frayed material; or locks, buckles, or hook-and-loop fasteners that do not hold securely. DO NOT use soiled or damaged products. Doing so may result in serious injury or death. Dispose of damaged products per facility policy for BIOHAZARDOUS material.

  3. ALWAYS secure straps to a part of the frame that moves with the patient (not foot/head board or siderails), out of the patients reach, using quick-  release ties (see drawing below) or buckles. These allow easy release in the event of an accident or fire. Test to make sure straps cannot tighten, loosen, or slip and create excess slack. If this occurs, the patient may slide off the chair or bed, increasing the risk of serious injury or suffocation. Restraint release is an important part of facility fire and disaster drills. Straps can be cut with scissors in
    an emergency.

  4. NEVER secure restraint strap to side rail or head/foot board.

  5. NEVER use Posey products on toilets, or on any chair or furniture that does not allow proper application as directed in the Application Instructions. DO NOT use at home.

  6. NEVER expose this product to open flame, fire, smoking materials, or high heat sources. Some products may melt or ignite and burn. The facility smoking/no smoking policy should be strictly enforced.

  7. NEVER use a Posey product as a seat belt in a moving vehicle. Posey products are not designed to withstand the force of a crash or sudden stop.

  8. Test Zippers or hook-and-loop fasteners before each use. DISCARD device if it does not fasten securely.

LAUNDERING INSTRUCTIONS (if applicable):

  • Fasten all buckles and locks to reduce risk of damage during wash and dry cycles. DO NOT put buckles or locks through extractors. For maximum life, launder in a laundry bag.
  • Stainless Steel Locks: Posey recommends that locks be treated with a dryfilm lubricant (silicone) after each cleaning. For best results, spray a small amount into the lock. Work the action of the lock with a key several times to ensure that all the surfaces are well lubricated.
  • Before laundering, zip up and turn the product inside out to protect zipper.
  • Hook-and-loop fasteners may collect lint after repeated use or laundering, reducing grip strength. Fasten the “hook” to the “loop” before laundering to help prevent lint buildup. As needed, use a stiff-bristle brush to remove lint from the “hook” side.

These products, other than foam products, can be machine washed under CDC guidelines for material soiled with blood or bodily fluid.

  • For non-contaminated material, use lower temperature wash and dry cycles to extend product life.
  • For foam products:
  • Make sure products are completely dry before use.

STORAGE AND HANDLING :

  • This device is designed for use in normal indoor environments.
  • This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.

HOW TO TIE THE POSEY QUICK-RELEASE TIE

Posey-2796-2797-Connected-Twice-as-Tough-Cuffs-for-Stretcher-
\(7\)

  1. Wrap strap once around the frame that moves with the patient (do not attach to side rail or head/footboard), leaving at least an 8” (20 cm) tail. Fold the loose end in half to create a loop and cross it over the other end.
  2.  Insert the folded strap where the straps cross over each other, as if tying a shoelace. Pull on the loop to tighten.
  3.  Fold the loose end in half to create a second loop.
  4. Insert the second loop into the first loop.
  5. Pull on the loop to tighten. Test to make sure strap is secure and will not slide in any direction.
  6. Repeat on other side. Practice quick-release ties to ensure the knot releases with one pull on the loose end of the strap.

DISPOSAL: Dispose of product according to local or facility guidelines if product is worn or damaged.

  • TIDI Products, LLC • 570 Enterprise Drive, Neenah, WI 54956 USA
  • Phone: 1.800.521.1314 • International: +1.920.751.4036
  • www.tidiproducts.com
  • © 2024 TIDI Products, LLC. All rights reserved. Posey is a registered trademark of TIDI Products, LLC.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals