SALTO IQ 3.0 BLUEnet Wireless Gateway
Product Specifications
- Device Type: Gateway
- Connectivity: Ethernet, WIFI, Bluetooth, RS-485
- Weight: 225g
- Dimensions: 122.5mm x 42mm
Product Usage Instructions
Installation Guide
The IQ3 device serves as a Gateway for communication between Nebula and
SALTO BLUEnet devices, enabling SVN features.
Installation Options
Ceiling/Wall Installation: Follow the provided diagram for hidden cable
installation.
Desktop Installation: Refer to the diagram for desktop mounting
instructions.
Connection Options
Ethernet + WIFI Model: Plug in the device to establish connectivity.
ETHERNET + POE Model: Connect the device using Ethernet and Power over
Ethernet.
ETHERNET Model: Simply plug in the Ethernet cable for connection.
Communication Wiring
Follow the provided wiring diagram to connect the device to SALTO Node for
communication.
External Power Supply
The device requires an external power supply except for PoE models.
Frequently Asked Questions (FAQ)
-
Q: What are the main connectivity options of the IQ3 device?
A: The IQ3 device offers connectivity through Ethernet, WIFI, Bluetooth, and RS-485 interfaces. -
Q: Does the IQ3 device support Power over Ethernet (PoE)?
A: Yes, some models of the IQ3 device support Power over Ethernet (PoE) for power supply.
The IQ3 is a Gateway device that ensures the communication between Nebula and
the SALTO BLUEnet devices providing the SVN (SALTO Virtual Network) features.
It is equipped with an Ethernet, WIFI (), Bluetooth and RS-485 interface.
() Depending on the model.
Installation
CEILING/WALL INSTALLATION WITH HIDDEN CABLE
CEILING/WALL INSTALLATION WITH EXPOSED CABLE
DESKTOP INSTALLATION
SEE WIRING DIAGRAM
Wiring
ETHERNET MODEL
ETHERNET + POE MODE
ETHERNET + WIFI MODEL
( * )Not included
ETHERNET MODEL
ETHERNET + POE MODEL
If there is no PoE infrastructure, use auxiliary power supply.
ETHERNET + WIFI MODEL
If you do not connect to a WIFI network, connect the Ethernet cable.
COMMUNICATION WIRING DIAGRAM IN IQ3/SALTO Node
RS485 CONNECTION TO TERMINAL.
RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus.
- Power (except PoE).
- Ethernet.
- RS485 (Jack cable).
- RS485.
Electrical Features
EXTERNAL POWER SUPPLY CHARACTERISTICS
| Min| Max| Typ
Input Voltage| 12-5%V| 12+5%V| 12V
Max Input Power| 15w| |
**Current Consumption***| | 200mA| 60mA
- Excluding RS485 Nodes.
Power supply must be calculated taking into account SALTO Nodes current consumption.
CABLE REQUIREMENTS
Ethernet ** UTP CAT5e
Node Connection| By means of Terminal Blocks: Generic twisted pair
By means of RJ45: UTPCAT5e
OPERATING CONDITIONS**
| Min| Max
Temperature| 0ºC| 60ºC
Humidity| 0| 95% (Non condensing)
SALTO BLUEnet CHARACTERISTICS
Frequency Range| 2400 MHz to 2483.5 MHz
Standard| Bluetooth 5.2 Compliant
TX power| 8dBm
Indoor Range| 10 – 15m *
WIFI CHARACTERISTICS
Frequency Range| 2400 MHz to 2483.5 MHz
Standard| IEEE 802.11b/g/n compliant
TX power| 16dBm
Range| 25 – 30m *
- Depending upon installed environment. To ensure correct operation, do not install the device near a metallic surface.
MAX. NUMBER OF DEVICES TO BE CONNECTED
SALTO Nodes 6
Access points 112
PoE
PoE Norms: IEEE 802.3af / IEEE 802.3at
PoE Class 0
- The environment has a direct impact on the BLUEnet range radiation (metal, concrete walls…)
The receiver device must be located facing the product antenna. Please check your product’s BLUEnet antenna position. Recommended connectivity distance: 10m – 15m
Configuration
- The device is configured using the Nebula App.
- Ethernet test: without any type of set up, the IQ3 is a DHCP ready device. If your network supports it, it is possible to check the Ethernet connectivity by pinging the address SALTO-IQ3-XXXXXX(XXXXXX corresponds to the final 6 digits of MAC).
Installation example
Maximum number of SALTO Nodes: 6
Maximum number of access points: 112
Signals
Operational test
- Check that the red light turns on.
- If you have connected to Ethernet, check that the lights on the RJ45 turn on.