SENSIRION SDP810 Differential Pressure Sensor Owner’s Manual
- July 11, 2024
- SENSIRION
Table of Contents
SENSIRION SDP810 Differential Pressure Sensor
Specifications
- Measurement range: Fully bi-directional
- Accuracy of measured value: 3% m.v.
- Lowest detectable pressure: N/A
- Measurement speed: N/A
- Measurement parameter: N/A
- Calibrated for: N/A
- Gas compatibility: Yes
SDP Selection Process
When selecting the appropriate SDP sensor, consider the target pressure range,
pneumatic connection, and electrical interface. Additionally, take into
account specific requirements such as dust resistance, measurement
sensitivity, and supply voltage to ensure the sensor meets your application
needs.
FAQ
Q: What factors should I consider when choosing an SDP sensor?
A: Factors to consider include target pressure range, pneumatic connection,
electrical interface, gas compatibility, dust resistance, measurement
sensitivity, and supply voltage.
SDP Selection Guide
Choose the right
Sensirion Differential Pressure sensor for your application
A precise measurement of gas flow often is key for the success of bringing a
technology into everyday life. Sensirion’s unique CMOSens technology fulfills
exactly this ambition for Sensirions Differential Pressure (SDP) sensor
series: high measurement precision at low gas flows is coupled with fast
measurement speed. The SDP is a microthermal flow sensor, ready for versatile
use as differential pressure sensor or as gasflow sensor in your application.
This versatility enables optimal use of the sensor in various gas flow
systems.
This selection guide provides a first-glance comparison of all key features of
the SDP sensor product portfolio. It allows a direct comparison between all
SDP sensors on the market.
The decision for the most suitable SDP is typically driven by the target
pressure range, pneumatic connection, and electrical interface. Other use
case-specific requirements can be dust resistance, measurement sensitivity, or
supply voltage.
SDP Sensor Portfolio
Table 1. Each SDP sensor series has its own characteristics. This table allows
for a direct comparison between the most relevant sensor parameters.
1 Sensor is compatible with inert gases. Sensor calibration is for air and
nitrogen. For the measurement of non-calibrated inert gases, a correction
factor may apply.
SDP Selection Process
This chapter guides you through the necessary steps to identify the right
sensor for your application. Relevant criteria are pressure ranges, pneumatic
connection and form factor.
After the selection process, Sensirion recommends continuing with sensor
evaluation and compatibility testing in the gas flow system of the target
application. Refer to the SDP Engineering Guide for details.
Measurement Range
SDP sensors are available with measurement ranges between 125 Pa to 1500 Pa
full scale. The most common measurement range is 500 Pa. Availability varies
between sensor series. The measurement principle of the sensor is particularly
effective at low pressure ranges: it provides excellent sensitivity at
pressures well below 0.01 Pa. Therefore, a sensor with a measurement range of
125 Pa is still a perfect choice for your application if you want to measure
in a range as low as ± 25 Pa.
For a translation of pressure range to mass flow or volume flow, the flow
characteristic of the overall gas flow system must be considered: for flow
measurements, the SDP sensor is commonly designed-in with the so-called
“bypass configuration”. Here, the differential pressure range is defined
through the specific flow system design with its pressure drop element.
Typical volume flows through the sensor are a few 10-fold mL/min. Other
application-dependent requirements can be measurement accuracy or measurement
speed.
Pneumatic Connection
SDP sensors are available with manifold connector or with tube connector.
Tube connectors are optimized for connection of the sensor to gas flow tubes.
Choose tube connectors if the sensor is not placed in direct proximity to the
gas flow chambers or channel of the gas flow system. The mechanical strength
of SDP tube connectors is not optimized for external device connection. Due to
their size, tube connectors can be offered only above a certain SDP form
factor.
Manifold connectors are for direct connection of the sensor with the gas flow
system. They are specifically suited for gas flow measurements in bypass
configuration. Sensirion recommends not connecting tubes with SDP manifold
connectors.
Form Factor
SDP8xx sensors with larger form factor (18 x 29 mm) are specifically designed
for applications with requirements on dust resistance (i.e. VAV controller).
They are available with tube and cable connectors. SDP3x sensors with smaller
form factor (5.5 x 8.5 mm) are specifically designed for applications with
requirements on light device weight (i.e. Smart Inhaler). They are available
with manifold connectors.
Production Handling
SDP electrical connection differs between sensor series. Sensors with cable
connection usually come with higher production efforts than sensors with
solder connection. Check with your production department whether a specific
solder technique is required for sensor assembly.
SDP shipping package and shipping volume depend on sensor form factor. Tray packages require manual sensor placement in production. Tape&Reel packages allow fully automated sensor placement. Details on shipping volumes are indicated in each SDP datasheet.
Start Testing
The evaluation method of your SDP sensor of choice depends on whether it has a
digital or an analog interface. The SDP is mostly used in digital versions.
Digital Sensor Evaluation
The fastest way to start an experiment is the SDP evaluation kit. It connects
to your computer through the SEK-SensorBridge, and the Sensirion ControlCenter
Software. Purchase your Evaluation Kit directly from our website.
Alternatively, we also offer an Arduino library, RaspberryPi drivers, and
Python drivers for your SDP experience on GitHub.
Sensirion recommends starting testing with the SDP8xx evaluation kit. It
features easy handling and provides straightforward connection of the sensor
to a lab bench test setup. While it comes with the SDP810-500 Pa sensor, you
can also connect and test any other digital SDP8xx sensor version.
Further Information
Useful Resources
For further details on Sensirion’s SDP sensor series, please visit our
website. Here, you can find many more information on sensor use and design-in
instructions.
- Product catalog Product catalog (sensirion.com)
- Technical download Technical download (sensirion.com)
- SDP sensor evaluation Differential pressure evaluation (sensirion.com)
- GitHub Sensirion AG · GitHub
- FAQ FAQ (sensirion.com)
- Technical Customer Support Support contact (sensirion.com)
Calibration
Thanks to the stability of the MEMS-based sensor element and the robust
mechanical design, Sensirion Differential Pressure Sensors, SDP, do not drift
and do not require recalibration in the field.
High manufacturing standards used during production ensure that our Differential Pressure Sensors are extremely reliable and have a very low failure rate. This is supported by field surveys and measurements.
Customized Solutions
Many SDP applications are successful with our standard products and benefit
from their economies of scale. However, some applications require customized
solutions. In case you can’t identify an SDP sensor that covers your specific
sensor need, Sensirion is ready to support your high-volume project. Please
contact us for details.
Revision History
Date | Version | Pages | Changes |
---|---|---|---|
01 2024 | 0.1 | all | Initial version |
06 2024 | 1.0 | all | Release |
Important Notices
Warning, Personal Injury
Do not use this product as safety or emergency stop devices or in any other
application where failure of the product could result in personal injury. Do
not use this product for applications other than its intended and authorized
use. Before installing, handling, using or servicing this product, please
consult the data sheet and application notes. Failure to comply with these
instructions could result in death or serious injury.
If the Buyer shall purchase or use SENSIRION products for any unintended or
unauthorized application, Buyer shall defend, indemnify and hold harmless
SENSIRION and its officers, employees, subsidiaries, affiliates and
distributors against all claims, costs, damages and expenses, and reasonable
attorney fees arising out of, directly or indirectly, any claim of personal
injury or death associated with such unintended or unauthorized use, even if
SENSIRION shall be allegedly negligent with respect to the design or the
manufacture of the product.
ESD Precautions
The inherent design of this component causes it to be sensitive to
electrostatic discharge (ESD). To prevent ESD-induced damage and/or
degradation, take customary and statutory ESD precautions when handling this
product. See application note “ESD, Latchup and EMC” for more information.
Warranty
SENSIRION warrants solely to the original purchaser of this product for a period of 12 months (one year) from the date of delivery that this product shall be of the quality, material and workmanship defined in SENSIRION’s published specifications of the product. Within such period, if proven to be defective, SENSIRION shall repair and/or replace this product, in SENSIRION’s discretion, free of charge to the Buyer, provided that:
- notice in writing describing the defects shall be given to SENSIRION within fourteen (14) days after their appearance;
- such defects shall be found, to SENSIRION’s reasonable satisfaction, to have arisen from SENSIRION’s faulty design, material, or workmanship;
- the defective product shall be returned to SENSIRION’s factory at the Buyer’s expense; and
- the warranty period for any repaired or replaced product shall be limited to the unexpired portion of the original period. This warranty does not apply to any equipment which has not been installed and used within the specifications recommended by SENSIRION for the intended and proper use of the equipment. EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH HEREIN, SENSIRION MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT. ANY AND ALL WARRANTIES,
INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, ARE EXPRESSLY EXCLUDED AND DECLINED.
SENSIRION is only liable for defects of this product arising under the
conditions of operation provided for in the data sheet and proper use of the
goods. SENSIRION explicitly disclaims all warranties, express or implied, for
any period during which the goods are operated or stored not in accordance
with the technical specifications.
SENSIRION does not assume any liability arising out of any application or use
of any product or circuit and specifically disclaims any and all liability,
including without limitation consequential or incidental damages. All
operating parameters, including without limitation recommended parameters,
must be validated for each customer’s applications by customer’s technical
experts. Recommended parameters can and do vary in different applications.
SENSIRION reserves the right, without further notice, (i) to change the
product specifications and/or the information in this document and (ii) to
improve reliability, functions and design of this product.
Headquarters and Subsidiaries
-
Sensirion AG Laubisruetistr. 50
-
CH-8712 Staefa ZH Switzerland
-
phone: +41 44 306 40 00 fax: +41 44 306 40 30 info@sensirion.com www.sensirion.com
-
Sensirion Taiwan Co. Ltd phone: +886 2 2218-6779 info@sensirion.com www.sensirion.com
-
Sensirion Inc., USA phone: +1 312 690 5858 info-us@sensirion.com www.sensirion.com
Sensirion Japan Co. Ltd. phone: +81 45 270 4506 info-jp@sensirion.com www.sensirion.com/jp -
Sensirion Korea Co. Ltd. phone: +82 31 337 7700~3 info-kr@sensirion.com www.sensirion.com/kr
Sensirion China Co. Ltd. phone: +86 755 8252 1501 info- cn@sensirion.com www.sensirion.com/cn -
To find your local representative, please visit www.sensirion.com/distributors
-
Copyright © 2024, by SENSIRION. CMOSens® is a trademark of Sensirion. All rights reserved
References
- Sensirion AG · GitHub
- Support contact
- Product catalog
- Download center
- Differential pressure evaluation
- Sensirion - Smart Sensor Solutions